Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT SUMMARY
Project Summary Job: wrightsoft: ,® Entire House. By: QUICK CALCS, INC. ST. LUCIE I.N., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796, Email: For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL VE Notes: `, Weather. Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 17848 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 He Cool"46 2 Area ft 1446 Volume (ft3) 12511 12511 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 94 48 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25H BC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual air flow Airflow factor Static pressure Space thermostat Capacity balance point = 32 OF Backu 8.5 HSPF 34600 Btuh @ 47°F 27 T 1160 cfm 0.049 cfm/Btuh 0.50 in H2O Input p7 kW, 'Output 23009 Btuh, 100 AFUE SCANNED By M. Woe GO* Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17520 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data Rate/swing multiplier n 0.95 Equipment sensible load 24753 Btuh Latent Cooling Equipment Load Sizing Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0' Btuh (none) Equipment latent load 5521 Btuh Equipment total load 30274 Btuh Req. total'capacity at 0.70 SHR 2.9 ton Cooling EquiprrfentSummary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800' Btuh Actual air flow 1160. cfm, Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Mant a gg Copy. wrightsoft, - - 2017-Apr-11 09:29:38 o — Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 '��` ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N wrightsoft Right-JO Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM 1 Room name Entire House BEDROOM 2 Exposed wall 156.2 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ft2 297.0 ft2 Ty Construction U-value Or ATM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) . Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A41ocS, .. 0 143 n 4.00 :'. 2.55 503 465 . ' 1862 i 1184 .1 72 ' 72 3289 183 I--G 4A6-2om' 13A4ocs t 0 0.143 • n a 21:56 4.00 19:31 2.55 38 128 0 83 815 333 730 212 0- 0 " 0 0 0 0 0 0 11 1Ac1om 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 24 21 2 21 848 229 2082 238 0 0 0 0 0 0 0 0 - � S .W - `'13A-4ocs V�/ Y_G 13A4ocs 1Ao1om 0.143 0.143 1270 se s s 4.00 4.00 35.56 2.55 2.55 34.77 34 360 7 34 353 7 136. 1414 247 86 899 241 .0 216 0 0 216 0 A 865 0 0 550 0 13A4ocs ". 1A-c1om ' 0.143 1.270 w • w 4.00 35:56 2.55 55.21 310 32 •237 2 949 1140 603 1770 104 32 72 2 288 1140 183 1770 '4A5-2om . .0.770 -w '21.56 .19.31 41 . 41 .. 880:. 788 0-- 0 0 0 P 12C-0sw 0.091 - 2.55 1.28 192 192 489 246 0 0 0 0 C ., 16A-89md .0.632. - ,Q.9Q . .2.3.2 . .1446 ,.. _1446 1295 :. '. 3354 297 ; : • 297, . : 266 F . 22A-tpl 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c)AED excursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 2000 0 Subtotal Qines 6 to 13) 17848 17520 5053 4925 Less external load 0 0 0 0 Less.transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400 F1Total room load 23503. 26116 6653 7325 Air required (ofm) 1160 1160 328 326 Calculations approved byACGA to' meet all'requirements of Manual J 8th Ed. -�- w.ightsoft- 2017-Apr-11 09:29:38 A Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...ulck Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N -r 1- wrightsoft° Right- 6i Worksheet Job: Entire House Date: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC WCHEN 2 3 FVosed wall Room height O ft 8.0 ft heat1cool O ft 8.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 9.0 ft 54.0 ft2 1.0 x 172.0 ft 172.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 13A flocs ,: "0.143 - rr .4.00 . .2 65 b 0 0 0 -, 0 0 0 0 4A5 tom; 13A-4ocs 0.770 0.143 n ` a 21.56 4.00 19.31 2.55 ... 0 0 .. 0 .0 0 0 . fo 0 0' 0 0. 0 0 0 0 0 11 1A-c1om 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W .- . VI! L--G :13A4ocs 13A-4ocs 1Aclom 0,143 0.143 1.270 se s s 4.00 4.00 35.56 2:55 2.55 34.77 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 V��I--G 13X46cs 0.143 . w 4.00 2.55 0 0 0 0 0 0 0 0 1A:clom - . 4A5.2om . . 1.270 0.770 . w , w '35.56 21.56 55.21 19:31 0 0 0 0 0 0 . 0 0 0 0 0 0 0 0 0 0 r- G P 12GOsw 0.091 - 2.55 1.28 0 0 0 0 64 64 163 82 C ' `11iA 30mtl .. 0.032 '- .0:90 232 54 ., 54 - 48 ; 125 172 ' 172'154 . .:.,399 F 22A-tol 0.989 - 27.69 0.00 54 0 0 0 172 0 0 0 6 c) AED excursion -9 -170 Envelope loss/gain 48 117 317 311 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal (lines 6 to 13) 48 117 317 2311 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 48 0 0 1171 0 0 317 0 .0 2311 15 Duct loads 32% 49% 15 57 32% 49% 100 1126 Total room load 64 174 418 3437 Air required (cfm) 3 8 21 153 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -- wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-4r-11 09:29:38 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N Page 2 - - wrightsoft Right4@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH BEDROOM 2 2 3 E)q)osed wall Room height 5.0 ft 8.0 ft heattcool 34.2 ft 8.0 ft heaticool 4 5 Room dimensions Room area 9.0 x 5.0 ft 45.0 ft2 1.0 x 203.5 ft 203.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/Wt *F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Stuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 r 13A�ocs 0143 0.770 0.143 - n: "n: a A 00 �21.56 4.00 2 55'. ` :.'19.31 2.55 40 :. 0: 0 40 ,. 0 0 160 0 0 s- 102 0 0 - 128 . ; p 80 , 128 . 0 56 i, W .. . :p 225 326 ' ; ,..p 143 . .G:.4A5.2om: ILS13A4ocs 11 1A-clom 11D0 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 24 0 2. 0 848 0 2082 0 W W �G 13A4ocs 13A-4ocs 1A-c1om 0.143 0.143 1.270 se s s 4.00 4.00 35.56 2.55 2.55 34.77 0 0 0• •0 0 0 0 0 0 0 0 0 34 32 0 34 32 0 136 128 0 86 81 0 13A4ocs 1Aoc om 0143 1.276 w w 4.00 35.56 2.55 . 55.21 0 - 0 0 0 0 0 .0 0 0 0 0 .0 0 0 0 0 P 4A5-2om 12C-0sw -,16X-30rnd% .0:770 0.091 0.032 .w - - 21:56 2.55 0.90 19.31 1.28. - 232 0 0 45: 0.,: 0 45 6 0 40..: .0 0 104 10 0 2W .0 0 .. 204., 0. 0 .. -.,182 ::.0 0 := 472 F 22A tpl 0.989 - 27.69 0.00 45 5 138 0 204 34 946 0 6 c)AED emursion -16 -85 Envelope loss/gain 339 190 29781 3106 12 a) Infiltration b) Room ventilation 87 0 24 0 593 0 162 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 1 230 0 Subtotal pines 6 to 13) 425 214 3571 3498 14 15 Less external load Less transfer Redistribution . Subtotal Duct loads 32% 49% p 0 0 135 p 0 0 104 32% 49% p 0 0 3571 1131 0 0 0 3498 1704 Total room load Air required (cfm) 560 28 318 14 1 4702 232 5203 232 Calculations approved byACCA to meet all requirements of Manual J.8th Ed �A � wrightsoft• Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 uick Calcs%Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Page 3 wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 E)posed wall 6.0 ft 47.0 ft 3 Room height 8.0 ft heat/cool 9.8 ft heat/cool 4 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 ft2 1.0 x 526.0 ft 526.0 ft2 Ty . Construction U-value Or HTM Area (ftz) Load Area (ft2) Load number (Btuhfft2-°F) (13tuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 v# r G; 13A466s: 4A5-2orn, 0143 :0.770 0.143 - - _n. ao h a 4 00 :21:56 4.00 „. 2.55 19.31 2.55 0 ' . 0 0 0 0 0 0 . -. 0 0 ,0 '0' 0 255 38 0 : 217 ' _ :0 0 869 "81Q 0 552 730 0 11T:213A-4ocs -11DO 1A-c1om 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W< tVI1 13A-4ocs 13A4ocs 0:143 0.143 'se s 4.00 4.00 2.55 2.55 0 48 0 48 0 192 0 122 0 0 0, 0 0 0 0 0 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 -G VL13A-4ocs 1Ac1om.. 0.143 1.270 w ` w 4.00 35.56. 2.55 55.21 0 .0 0 0 0 0 0 . 0 206 0. ' 165 '0 . 661 0 420 0 4A54om 12C-Osw 16A Omd.. 0.770 0.091 0.032 w - - 21.56 2.55 0:90 19.31 1.28 232 0 56 42 01 56 42 0 143 38 .0 72 97 41 0 . 526: 41 0 526 880. 0 471 7W 0 - .-1220 P C F 22A-tpl 0.989 - 27.69 O.OD 42 6 166 0 _ 52.6 " 47 1302 ,;, 0 6 c)AED excursion -22 666 Envelope loss`/gain 539 270 4997 4379 12 a) Infiltration b) Room ventilation 104 0 28 0 997 0 273 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 2 460 0 Subtotal (lines 6 to 13) 643 298 5994 5112 14 15 1 Less e)demal load Less transfer Redistribution Subtotal Duct loads 32% 49% 0 0 0 643 204 0 0 0 298 145 32% 49% 0 0 0 5994 1899 0 0 0 5112 2490 Total room load ' Air required (cfm) 846 42 443 20 1 1 7892 390 7602 338 Calculations approved byACCA to meet all requirements of. Manual J 8th Ed A - wrightsoft� Right -Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 ..:uick Calcs\DbcumentslTHE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Page 4 - wrightsoft, Right-M Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@/AOL.COM Job: Date: By: 1 nameFOYER M. BATH 2 Exposed wall 7.0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 50.0 ft 50.0 ft2 7.0 x 8.0 ft 56.0 ft2' Ty Construction U-value Or HTM Area (ft 2) Load Area (ft2) Load number Btuh/ft2-°F ( ) Btuh/ft2 ( ) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 y/ L 'G` 13A4ocs , AA5-2om. ' : 13A-4ocs 0143 0.770 0.143 :. n ' .6 a 4:00 21.66. 4.00 2.55 19.31 2.55 $ 0 48 8 0 27 32 0 108 .:. 20 0 69 0, 0 0 - 0 - 0 0 0 . 0. 0 0 0 11 � 1A-c1om 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 21 0 21 0 229 0 238 0 0 0 0 0 0 0 0 W W .13A-4ocs 13A-4ocs 1Ac1om 0.143 0.143 1.270 se s s 4.00 4.00 35.56 Z55 2.55 34.77 0 0 0 0 0 0 0 0 0 0 0 0 0 64 7 0 57 7 6 228 247 0 145 241 -G P C- F 13A4ocs 1Ao1om 4A5-2om 12C-0sw 16M-Clmd_ 22A-tpl .0.143 1.270 0.770 0.091 0:032 0.989 w w w - - - 4:00 35.56.- 21.56 2.55 0:90 27.69 2.55 55.21 19.31 1.28 2.32 0.00 0 0 0 72 - 50 50 0 0 0. 72 50 7 0 0 0 183 45 194 0 0- 0 92 _ 116 0 0- 0 0 0 56 56 0 0 0 0 56 8 0 0 6 0 50 222 0 0 0 0 . 930 0 6 c)AED excursion -39 Envelope loss/gain 792 496 747 478 12 a) Infiltration b) Room ventilation 121 0 33 0 138 0 38 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 913 529 885 516 14 15 Less edemal load Less transfer Redistribution .Subtotal Duct loads 32% 49% 0 0 0 913 289 0 0 0 529 258 32% 49% 0 0 0 885 280 0 0 0 516 251 Total room load Air required (cfm) 1202 59 787 35 1166 58 768 34 Room to meet all requirements of Manual J 8th wrightsoft- Right-SuiteO Universal 2017 17.0.14 RSU08101 uick Calcs\Documents\THE GRAND CARLTON 1446.rup Calc = MJS Front Door faces: 2017-Apr-11 09:29:38 Page 5