Loading...
HomeMy WebLinkAboutBLOWER DOOR TEST FORM - TEST CERTIFICATIONPlanning & Development.Services Building & Code Regulation Division 23W Virginia Ave, Rm,201 Fort Pierce, FL 34982 Phone' 772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method SCANNED BY St. U06 County Date: Permit #:�,D Contractor:��!} -e! Job Address: Y ,� 4 •PQ% C✓ c:� , /�� Construction: () New Construction — Complete ( ) Existing — After Addition House Infiltration Test Results SLC Climate Zone 2 CFM'(50) _ - 12 C7 Test Date: 6/ " Volume = f k2d ACH.(50) = CFM (50) x 60 /Volume =� y M�hanical Ventilation required less than SACH Passing results must be, & ACH (50) or less (� Pass ( ) Fail FBC, Energy The. building or dwelling unit shall be tested and verified as having an.airleakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2:and 3 air changes per hour in Cli blower door at a pressure of 0:2 inches w. g. mate Zones 3 through 8. Testing shall be conducted with a (50 Pascals). Testing shall be conducted by either individuals as defined.in Section 553.993(5) or (7), Florida Statutes. or individuals licensed as set forth in Section 489:105.(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code officicl. Testing shall be performed at any time after creation of all penetrations of the building thermal -envelope. FBC, Residential Where the air infiltration rate of a dwelling unit is less than 5 air changes per hour when tested with a blower door at a pressure of 0.2 inch w.-c. (50 Pa) in accordance withSection R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole=house mechanical ventilation in;accordance with Section M3507.3. Testing Comoanv Company Name: Pro Duct Services Address: 1915 Rio Vista dr., Fort Pierce; fl. I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section. R402.4.1.2 Climate Zone 2. Signature: Printed Name: Michael Faurot license/Certification #: 5059122