HomeMy WebLinkAboutBLOWER DOOR TEST FORM - TEST CERTIFICATIONPlanning & Development.Services
Building & Code Regulation Division
23W Virginia Ave, Rm,201
Fort Pierce, FL 34982
Phone' 772-462-2165 Fax:772-462-6443
BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
SCANNED
BY
St. U06 County
Date: Permit #:�,D
Contractor:��!} -e!
Job Address: Y ,� 4 •PQ% C✓ c:� , /��
Construction: () New Construction — Complete ( ) Existing — After Addition
House Infiltration Test Results SLC Climate Zone 2
CFM'(50) _ - 12 C7 Test Date: 6/ "
Volume = f k2d
ACH.(50) = CFM (50) x 60 /Volume =� y M�hanical Ventilation required less than SACH
Passing results must be, & ACH (50) or less (� Pass ( ) Fail
FBC, Energy
The. building or dwelling unit shall be tested and verified as having an.airleakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2:and 3 air changes per hour in Cli
blower door at a pressure of 0:2 inches w. g. mate Zones 3 through 8. Testing shall be conducted with a
(50 Pascals). Testing shall be conducted by either individuals as defined.in
Section 553.993(5) or (7), Florida Statutes. or individuals licensed as set forth in Section 489:105.(3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code officicl. Testing shall be performed at any time after creation of all penetrations of the building
thermal -envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 5 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w.-c. (50 Pa) in accordance withSection R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole=house mechanical ventilation in;accordance with Section M3507.3.
Testing Comoanv
Company Name: Pro Duct Services Address: 1915 Rio Vista dr., Fort Pierce; fl.
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section. R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Michael Faurot
license/Certification #: 5059122