HomeMy WebLinkAboutEFFICIENCY CODEORM R405-2017
LORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Ploject
Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT S(QANN5r=v
L�J
;reet: THE STERLING Permit Office: ST. LUCIE COUNTY
�ty State, Zip: FT. PIERCE, FL , Permit Number: U
ner: ���� r� Jurisdiction: .Lucie��� Y
/^�
sign Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 )
1. ew construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.) Insulation Area
2. 3ingle family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2
III
b. Frame - Wood, Adjacent R=11.0 192.00 ft2
3. umber of units, if multiple family 1
c. N/A R= ft2
4. umber of Bedrooms 2
d. N/A R= ft2
5. this a worst case? Yes
10. Ceiling Types (1474.0 sqft.) Insulation Area
a. Under Attic (Vented) R=30.0 1474.00 ft 2
6. onditioned floor area above grade (ft2) 1474
b. N/A R= ft2
onditioned floor area below grade (ft2) 0
c. N/A R= ft2
11. Ducts R ft2
7. 1 indows(141.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic 6 300
U-Factor: Sgl, U=0.63 101.25 ft2
SHGC: SHGC=0.25
U-Factor: Sgl, U=0.65 40.00 ft2
12. Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit 34.8 SEER:15.00
U-Factor: N/A ft2
SHGC:
13. Heating systems kBtu/hr Efficiency
U-Factor: N/A ft2
a. Electric Heat Pump 34.8 HSPF;8.50
SHGC:
A'ea Weighted Average Overhang Depth: 3.832 ft.
II ea Weighted Average SHGC: 0.239
14. Hot water systems
8. oor Types (1473.5 sqft.) Insulation Area
a. Electric Cap: 40 gallons
.
a Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2
b. Conservation features EF: 0.970
b N/A R= ft2
None
c N/A R= ft2
15. Credits Pstat
Glass/Floor
Area: 0.096 Total Proposed Modified Loads: 48.34 PASS
Total Baseline Loads: 48.53
I he
certify that the plans and specifications covered by
Review of the plans and 4Z14E Sr'q?'
this
Cod
ieby
calculation are in compliance with the Florida Energy
e.
specifications covered by this��
calculation indicates compliance
Florida Energy Code.
PR
PAR BY:
with the
Before construction is completed
DA
E: '�
this building will be inspected for O T u
compliance with Section 553.908 * "'
I he
with
eby certify that this building, as designed, is in compliance
the Florida Energy Code.
Florida Statutes.
COD WF
OER
E,P1,T
BUILDING OFFICIAL:
DA
DATE:
CIE'
- cdIImpliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
ce !fled factory�sealed in accordance with R403.3.2.1.
-Co pliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
env lope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4/1 �/2018 12:27 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
�
FORM
I
R405-2017
PROJECT
tile.
WYNNE THE STERLING Bedrooms: 2
Address Type:
Street Address
Type: User Conditioned Area: 1474
Lot #
Iwlding
wner Name: Total Stories: 1
Block/Subdivision:
of Units: 1 Worst Case: Yes
PlatBook:
Name: WYNNE DEVELOPMENT Rotate Angle: 180
Street:
THE STERLING
guilder
ermit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
J
l risdiction: Whole House Fan: No
City, State, Zip:
FT. PIERCE ,
mily Type: Single-family
FL,
ew/Existing: New (From Plans)
Ipmment:
II
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
I
FL, Fort Pierce FL VERO BEACH_MUNI 39 90
I
70
75 299
62
Low
�I BLOCKS
I�Iumber
Name Area Volume
1 Entire House 1474 11792
SPACES
umber Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
BEDROOM 329 2632 No 0
1
1 Yes
Yes
Yes
WIC 63 504 No 0
1 No
Yes
Yes
M.BATH 56 448 No 0
1 Yes
Yes
Yes
KITCHEN 192 1536 Yes 0
1 No
Yes
Yes
BATH 45 360 No 0
1 Yes
Yes
Yes
BEDROOM 2 204 1632 No 0
1
1 Yes
Yes
Yes
ENTRY 55 440 No 0
1 Yes
Yes
Yes
LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
GREAT/DINING 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0
329 ft2
----
0 1
0
I' 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0
63 ft2
----
0 1
0
3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0
56 ft2
----
0 1
0
4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0
192 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulatio BATH 5 ft 0
45 ft2
----
0 1
0
6SIab-On-Grade Edge Insulatio BEDROOM 2 32.2 ft 0
203.5 ft2
----
0 1
0
7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0
55 ft2
----
0 1
0
4/1
2018 12:27 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 2 of 5
1� -
FORM R405-2017
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY Eft
0
42 ft2
----
0
1
0
I
I
9SIab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
----
0
1
0
ROOF
Roof
Gable
Roof
Solar
SA
Emitt
Emitt
Deck
Pitch
# Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
I I
1 Gable or Shed Metal 1553 ft2
246 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
II
# Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
I'I
1 Full attic Vented
150
1474 ft2
N
N
I'
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
329 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
I
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
II
I I
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
WALLS
1, fi
Adjacent Space Cavity Width
Ornt In Wall Type
Height
Sheathing Framing
Solar
Below
1
NE=>SW Exterior Concrete Block - Ext InsiHEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
2
SW=>NE Exterior Concrete Block - Ext InsiHEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.6
0
3
NW=>SE Exterior Concrete Block - Ext InsiHEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
4
SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.6
0
5
NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.6
0
6
NE=>SW Exterior Concrete Block - Ext ImMDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.6
0
7
SE=>NW Exterior Concrete Block - Ext InfiEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
8
S=>N Exterior Concrete Block - Ext InQEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.6
0
_ 19
SW=>NE Exterior Concrete Block - Ext InfiffDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.6
0
0
SE=>NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
11
SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.6
0
12
SW=>NE Exterior Concrete Block - Ext InsalAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
3
NE=>SW Exterior Concrete Block - Ext InsGREAT/DINI
4.1 26
0 8
0
208.0 ft2
0
0
0.6
0
4
NW=>SE Exterior Concrete Block - Ext InsGREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.6
0
5
N=>S Garage Frame - Wood KITCHEN
11 24
8
192.0 ft2
0.23
0.6
0
4/1',I/2018 12:27 PM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 3 of 5
i.
FORM R405-2017
DOORS
# Ornt
Door Type Space
Storms U-Value Width
Ft In
Height
Ft In
Area
ICI
1 SE=>NW
Insulated ENTRY
None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
# Ornt ID Frame
Panes NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
0.63 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in
0.63 0.25 N 6.9 ft' 1 ft 0 in 1 ft 4 in
0.63 0.25 N 24.0 ftZ 6 ft 0 in 1 ft 4 in
0.63 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in
0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315ft2
315ft2
24ft 8ft
11
INFILTRATION
#
Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1
Wholehouse Proposed ACH(50) .000356
1375.7 75.53 142.04 .2598
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
Il
1 Electric Heat Pump/ Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.85 1
sys#1
I'
HOT WATER SYSTEM
# System Type
SubType Location
EF Cap Use SetPnt
Conservation
1 Electric
None Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume FEF
Id
None None
ft2
4/1 7(2018 12:27 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
F0 M R405-2017
DUCTS
-- Supply
--
--- Return ---
Air
CFM 25
CFM25
HVAC #
# Location R-Value
Area
Location
Area
Leakage
Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6
300 ftZ
Attic
75 ftZ
Default Leakage
Attic
(Default) (Default)
1 1
I�
TEMPERATURES
�'rogramable
Thermostat: Y
Ceiling Fans:
Q)oling
H
Jan
Jan
atin9 H
Feb
Feb
Mar
Mar
ki
[
[ ]
Apr
Appr I
May
May
Jun
Jun
ri
Jul
Jul
rl
Aug
Aug
rl
Sep
Sepp
rl
Oct
Oct
Nov
Dec
X Dec
V
Jan
Feb
Mar
[X]
Apr
May
Jun
Jul
Aug
Se
[x]
Oct
XNov
X Nov
[ Dec
Th
rmostat Schedule:
HERS 2006 Reference
Hours
Sc
edule Type
1
2
3
4
5
6
7
8
9
10
11
12
Co
ling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling
(WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
He
ting (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
He
ting (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
7/2018 12:27 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
Il
017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT
Street: THE STERLING Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
A continuous air barrier shall be installed in the building P
9 envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
eiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
alls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
indows, skylights
The space between window/door jambs and framing, and
ili�d doors
skylights and framing shall be sealed.
lm joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
'oors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(
cluding
insulation.
maintain permanent contact with the underside of
Bove -garage
subfloor decking, or floor framing cavity insulation
d cantilevered
shall be permitted to be in contact with the top side
ors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
iawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls,
afts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
cavities
cavities shall be filled by insulation that on
�rrow
installation readily conforms to the available cavity
spaces.
Ga11
rage separation
Air sealing shall be provided between the garage and conditioned spac
as.
R
cessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
I
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
P
'� mbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and woring-
S 'lower/tub
The air barrier installed at exterior walls adjacent to showers and
1
Exterior walls adjacent to showers and tubs shall
1
or ,exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
El
ictrical/phone box or
The air barrier shall be installed behind electrical or communication
e
erior walls
boxes or air -sealed boxes shall be installed.
H
;AC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
C
; cealed
When required to be sealed, concealed fire sprinklers shall only be
s P
''nklers
sealed in a manner that is recommended by the manufacturer.
I�
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ceilings,
a. If
aaition,inspection or log walls shall be In accordance with the provisions of ICC-400.
4/1018 12:27 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
. F R`M R405-2017
7
8.
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
THE STERLING, FT. PIERCE, FL,
New construction or existing
Single family or multiple family
Number of units, if multiple family
Number of Bedrooms
Is this a worst case?
Conditioned floor area (ft2)
Windows—
Description
a. U-Factor:
Sgl, U=0.63
SHGC:
SHGC=0.25
�. U-Factor:
Sgl, U=0.65
SHGC:
SHGC=0.21
;. U-Factor:
N/A
SHGC:
J. U-Factor:
N/A
SHGC:
4rea Weighted Average Overhang Depth
4rea Weighted Average SHGC:
Floor Types
i. Slab -On -Grade Edge Insulation
�. N/A
;. N/A
New (From Plans)
9. Wall Types
Single-family
a. Concrete Block - Ext Insul, Exterior
b. Frame - Wood, Adjacent
1
c. N/A
2
d. N/A
10. Ceiling Types
Yes
a. Under Attic (Vented)
1474
b. N/A
Area
c. N/A
101.25 ft2
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
40.00 ft2
12. Cooling systems
ft2
a. Central Unit
ft2
3.832 ft.
0.239
Insulation Area
R=0.0 1473.50 ft2
R= ft2
R= ft2
13. Heating systems
a. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I ce ify that this home has complied with the Florida Energy Efficiency Code for Building
Cor struction through the above energy saving features which will be installed (or exceeded)
in t I is home before final inspection. Otherwise, a new EPL Display Card will be completed
ba d on installed Code compliant features.
Bui er Signature:
Adc ress of New Home: ^�.Q C� City/FL Zip7—s�
Insulation
Area
R=4.1
1250.00 ft2
R=11.0
192.00 ft2
R=
ft2
R=
ft2
Insulation
Area
R=30.0
1474.00 ft2
R=
ft2
R=
ft2
R ft2
6 300
kBtu/hr Efficiency
34.8 SEER:15.00
kBtu/hr Efficiency
34.8 HSPF:8.50
Cap: 40 gallons
EF: 0.97
Pstat
y04'SHE Srq?�
;o
COD W>r"��y
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/17/2018 12:27 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1