HomeMy WebLinkAboutBLOWER DOOR TEST - CERTIFICATIONa121f ek,
0
Planning to & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Ism 201
Fort Pierce, FL 34962
Phone:772-462-2165 Fax:772-462-6443
BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
Permit #: 1 9 o 9- 0 6 q
ntractor: V--I A,.Q.
a Address: Zo M.n+a 1fk, � �f ev LC, �L 3 `f g S 1
RECEIVED
�- op to
AUG 0 2 YD19
Permitting Department
St. Lucie County
) New Construction — Complete ( ) Existing —After Addition
use Infiltration Test Results SLC Climate Zone 2
M (50) = i o 3'1 Test Date: Q Z
lume = 1 Is6e
H (50) = CFM (50) x 60 / Volume = 5, Lf- Mechanical Ventilation required less than 3 ACH
;sing results must be & ACH (50) or less V Pass ( ) Fail
Energy ,
building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
r in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
ver door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
:ion 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
roved third party. A written report of the results of the test shall be signed by the party conducting the test and
Tided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
mal envelope.
, Residential
ire the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
:sure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
pany Name: Pro -Duct Services
Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
cents in accordance with Section R402.4.1.2 Climate Zone 2.
Name: Martin Klein
on #: 5061633