Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEe t A F RM R405-2017 �F ORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Prl�ject Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. SCANNED sdpt 2 �(�� ��Permit Office: ST. LUCIE COUNTY BY COi tate, Zip: . PIERCE, FL, Permitber: '92° LOA coum W rNNE BUILDING CROP ST. LUCIE COUNTY - Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) ii 1. construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. ingle family or multiple family Single-family Ingle a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. umber of units, if multiple family 1 c. N/A R= ft2 4. 'I u1.mber of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1446.0 sqft.) Insulation Area 5. I this a worst case? Yes a. Under Attic (Vented) R=30.0 1446.00 ft2 6. onditioned floor area above grade (ft2) 1446 b. N/A R= ft2 londitioned floor area below grade (ft2) 0 c. R= ft2 11. Ducts R ft2 7. indows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 "U-Factor: Sgl, U=0.36 101.25 ft2 `.SHGC: SHGC=0.25 f U-Factor: Sgl, U=0.65 40.00 ft 2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 cl U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency U-Factor: N/A ft2 Electric Heat Pump 34.8 HSPF:8.50 SHGC: Ia. rea Weighted Average Overhang Depth: 3.832 ft. Aie Weighted Average SHGC: 0.239 14. Hot water systems 111 a. Electric Cap: 40 gallons 8. Ffloor Types (1445.5 sqft.) Insulation Area EF:0.970 aI Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 NIA R= b. Conservation features ft2 nl N/A R= None ft2 it 15. Credits Pstat GIss/Floor Area: 0.098 Total Proposed Modified Loads: 47.17 PASS Total Baseline Loads: 48.08 I hil reby certify that the plans and specifications covered by Review of the plans and 41$E S1rq?� thi calculation are in compliance with the Florida Energy 0 specifications covered by this Cotle. calculation indicates compliance -`` , with the Florida Energy Code. h uun:= '"•- - =`' •°� PF, P D DA E: '" Y:b4b416 Before construction is completed this building will be inspected for compliance with Section 553.908 * "' I hi relay certify that this building, as designed, is in compliance Florida Statutes. G'OD wit it the Florida Energy Code. WE O'li NER BUILDING OFFICIAL: D .I', R:ffl55V DATE: I i ompliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as - c�rtified factory -sealed in accordance with R403.3.2.1. ompliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an en elope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE. py 4 17/2018 3:41 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 n: FORM R405-2017 • PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address B Iding Type: User Conditioned Area: 1446 Lot # OI mer Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # I If Units: 1 Worst Case: Yes PlatBook: B I Ider Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: P1' mit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie J isdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, F ily Type: Single-family FL, N /Existing: New (From Plans) C II Imment: � CLIMATE Design Temp Int Design Temp Heating Design Daily Temp, Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range I FL, Fort Pierce_ FL_VERO_BEACH _MUNI 39 90 I 70 75 299 62 Low BLOCKS +.tuber Name Area Volume I Entire House 1446 11568 ' SPACES umber Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated BEDROOM 301 2408 No 0 1 1 Yes Yes Yes WIC 63 504 No 0 1 No Yes Yes M.BATH 56 448 No 0 1 Yes Yes Yes KITCHEN 192 1536 Yes 0 1 No Yes Yes ' BATH 45 360 No 0 1 Yes Yes Yes BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes ENTRY 55 440 No 0 1 Yes Yes Yes LAUNDRY 42 336 No 0 1 Yes Yes Yes GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS I # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ---- 0 1 0 ' 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ____ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft2 _--- 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 ---- 0 1 0 4/I /2018 3:41 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 G G GnR A Rdn,,_7n17 FLOORS :� # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet _l� 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ____ 0 1 0 LI9 Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 0 1 0 IC Slab -On -Grade _--_ jl ROOF III Roof Gable Roof Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Absor. Tested Tested Insul. (deg) II J 1 Gable or Shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio in) Area RBS IRCC i (1 I!I 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood III 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood li 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood III 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood III lil 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS III Adjacent Cavity Width Space Height n Et rea Sheathing Framing Solar Below o ! 1 NE=>SW Exterior Concrete Block - Ext InsiflEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 III 2 SW=>NE Exterior Concrete Block - Ext InsIBEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext InsIHEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 II 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 III 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 II 6 NE=>SW Exterior Concrete Block - Ext InREDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext InMEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 �I 8 S=>N Exterior Concrete Block - Ext InEEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 IT 9 SW=>NE Exterior Concrete Block - Ext InfiffDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 i 1.0 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 III 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext InsLI1AUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 II 13 NE=>SW Exterior Concrete Block - Ext InsGiREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 lil 14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 4 I 15 I N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 i 41 ��1712018 3:41 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 it GnR A RdnF_7nl7 DOORS II # Ornt I'l Door Type Space Storms U-Value Width Ft In Height Ft In Area LL 1 SE=>NW �Il Insulated ENTRY None .39 3 1 6 8 20.6 ft2 II WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening �1I' 1 NW=>SE 3 Metal IL 2 SW=>NE 4 Metal 1L 3 SE=>NW 7 Metal 4 NE=>SW13 Metal III 5 NW=>SE14 Metal III Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.36 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in 0.36 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in 0.36 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in 0.36 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in 0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 li GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315ft2 III 315ft2 24ft 8ft 11 1 INFILTRATION # 'l Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 I', Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ II4 Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 L COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ III Split SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 I� HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric I� None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM II FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None Id ft2 7/2018 3:41 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 IA RdnF-7nl7 DUCTS ---- Supply --- ---- Return ---- Air CFM 25 CFM25 HVAC # II # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ftz Attic 65 ftz Default Leakage Attic (Default) (Default) 1 1 I I� I TEMPERATURES P[,ogramable Thermostat: Y Ceiling Fans: C Hg' II lin [[ ]] Jan Feb tin9 [X] Jan Feb ]Mar f X] Mar E A r [ Apr [ j May ] May [X] Jun [ ] Jun Jul Jul ri Aug Au ri Se Sep [ ]Oct [ ] Oct (]Nov [Nov Dec Dec V tin [[ ]] Jan Feb [[X] Mar _� [X A r [ j Ma [ ] Jun Jul Aug Se [X] Oct [X] Nov Dec Thq�mostat Schedule: HERS 2006 Reference Hours Scl�ldule Type 1 2 3 4 5 6 7 8 9 10 11 12 Co01 ing (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM I 80 80 78 78 78 78 78 78 78 78 78 78 Co ing (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Hea ing (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 He ing (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 II. PM 68 68 68 68 68 68 68 68 68 68 66 66 7/2018 3:41 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 I . 17 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce I ilCOMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA eneral A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall quirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. eiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit - the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. alls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. )111indows, skylights The space between window/doorjambs and framing, and nd doors skylights and framing shall be sealed. im joists Rim joists shall include the air barrier. Rim joists shall be insulated. loors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to ncluding insulation. maintain permanent contact with the underside of bove-garage subfloor decking, or floor framing cavity insulation nd cantilevered shall be permitted to be in contact with the top side oors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from.the bottom to the top of all perimeter floor framing members. rawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls hafts, penetrations Duct shafts, utility penetrations, and flue shafts opening y P p g to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow arrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. arage separation Air sealing shall be provided between the garage and conditioned spac as. ecessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. lumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pmpong and wirmng- t hower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall n exterior wall tubs shall separate them from the showers and tubs. be insulated. flectrical/phone box or The air barrier shall be installed behind electrical or communication xterior walls boxes or air -sealed boxes shall be installed. VAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. , oncealed When required to be sealed, concealed fire sprinklers shall only be prinklers sealed in a manner that is recommended by the manufacturer. 1 I Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a!i In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4�I17/2018 3:41 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 I F 1. 2. 3. 4. 5. 6. 7. 8 I co Co in 1 Bu R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. FT. PIERCE, FL, lew construction or existing New (From Plans) 9. Wall Types Insulation Area ingle family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft lumber of units, if multiple family 1 c. N/A R= ft2 lumber of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types Insulation Area s this a worst case? Yes a. Under Attic (Vented) R=30.0 1446.00 ft2 :onditioned floor area (ft2) 1446 b. N/A R= ft2 Vindows** Description Area c. N/A R= ft2 U-Factor: Sgl, U=0.36 101.25 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 250 SHGC: SHGC=0.25 U-Factor: Sgl, U=0.65 40.00 ft2 SHGC: SHGC=0.21 12. Cooling systems kBtu/hr Efficiency U-Factor: N/A ft2 a. Central Unit 34.8 SEER:15.00 SHGC: U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 34.8 HSPF:8.50 rea Weighted Average. Overhang Depth: 3.832 ft. rea Weighted Average SHGC: 0.239 loor Types Insulation Area 14. Hot water systems Cap: 40 gallons Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 a. Electric EF: 0.97 N/A R= ft2 N/A R= ft2 b. Conservation features None 15. Credits Pstat Ify that this home has complied with the Florida Energy Efficiency Code for Building JOE ST truction through the above energy saving features which will be installed (or exceeded) .y�� jNs home before final inspection. Otherwise, a new EPL Display Card will be completed d on installed Code compliant featur er Signature: Date: less of New Home: �� ��'�.� City/FL Zip-QSLQ �.c IT � �'f �� WE "Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. 1**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/17/2018 3:41 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1