HomeMy WebLinkAboutENERGY EFFICIENCY CODEe t
A
F RM R405-2017
�F ORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Prl�ject
Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. SCANNED
sdpt
2 �(�� ��Permit Office: ST. LUCIE COUNTY BY
COi
tate, Zip: . PIERCE, FL, Permitber:
'92° LOA coum
W rNNE BUILDING CROP ST. LUCIE COUNTY -
Design
Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 )
ii
1. construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.) Insulation Area
2. ingle family or multiple family Single-family
Ingle
a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2
b. Frame - Wood, Adjacent R=11.0 192.00 ft2
3. umber of units, if multiple family 1
c. N/A R= ft2
4. 'I u1.mber of Bedrooms 2
d. N/A R= ft2
10. Ceiling Types (1446.0 sqft.) Insulation Area
5. I this a worst case? Yes
a. Under Attic (Vented) R=30.0 1446.00 ft2
6. onditioned floor area above grade (ft2) 1446
b. N/A R= ft2
londitioned floor area below grade (ft2) 0
c. R= ft2
11. Ducts R ft2
7. indows(141.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic 6 250
"U-Factor: Sgl, U=0.36 101.25 ft2
`.SHGC: SHGC=0.25
f U-Factor: Sgl, U=0.65 40.00 ft 2
12. Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit 34.8 SEER:15.00
cl U-Factor: N/A ft2
SHGC:
13. Heating systems kBtu/hr Efficiency
U-Factor: N/A ft2
Electric Heat Pump 34.8 HSPF:8.50
SHGC:
Ia.
rea Weighted Average Overhang Depth: 3.832 ft.
Aie Weighted Average SHGC: 0.239
14. Hot water systems
111
a. Electric Cap: 40 gallons
8. Ffloor Types (1445.5 sqft.) Insulation Area
EF:0.970
aI Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2
NIA R=
b. Conservation features
ft2
nl
N/A R=
None
ft2
it
15. Credits Pstat
GIss/Floor Area: 0.098 Total Proposed Modified Loads: 47.17 PASS
Total Baseline Loads: 48.08
I hil reby certify that the plans and specifications covered by
Review of the plans and 41$E S1rq?�
thi calculation are in compliance with the Florida Energy
0
specifications covered by this
Cotle.
calculation indicates compliance
-`` ,
with the Florida Energy Code. h uun:= '"•- - =`' •°�
PF, P D
DA E: '" Y:b4b416
Before construction is completed
this building will be inspected for
compliance with Section 553.908 * "'
I hi relay certify that this building, as designed, is in compliance
Florida Statutes.
G'OD
wit it the Florida Energy Code.
WE
O'li NER
BUILDING OFFICIAL:
D .I', R:ffl55V
DATE:
I
i ompliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
- c�rtified factory -sealed in accordance with R403.3.2.1.
ompliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
en elope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FILE.
py
4 17/2018 3:41 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
n:
FORM
R405-2017
• PROJECT
Title:
WYNNE THE GRAND CARL Bedrooms: 2
Address Type:
Street Address
B
Iding Type: User Conditioned Area: 1446
Lot #
OI
mer Name: WYNNE BUILDING CROP Total Stories: 1
Block/Subdivision:
# I
If Units: 1 Worst Case: Yes
PlatBook:
B
I Ider Name: WYNNE BUILDING COPR. Rotate Angle: 180
Street:
P1'
mit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
J
isdiction: ST. LUCIE COUNTY Whole House Fan: No
City, State, Zip:
FT. PIERCE,
F
ily Type: Single-family
FL,
N
/Existing: New (From Plans)
C II
Imment:
�
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp,
Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
I
FL, Fort Pierce_ FL_VERO_BEACH _MUNI 39 90
I
70
75 299
62
Low
BLOCKS
+.tuber Name Area Volume
I
Entire House 1446 11568
' SPACES
umber Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
BEDROOM 301 2408 No 0
1
1 Yes
Yes
Yes
WIC 63 504 No 0
1 No
Yes
Yes
M.BATH 56 448 No 0
1 Yes
Yes
Yes
KITCHEN 192 1536 Yes 0
1 No
Yes
Yes
' BATH 45 360 No 0
1 Yes
Yes
Yes
BEDROOM 2 204 1632 No 0
1
1 Yes
Yes
Yes
ENTRY 55 440 No 0
1 Yes
Yes
Yes
LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
GREAT/DINING 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
I # Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0
301 ft2
----
0 1
0
2 Slab -On -Grade Edge Insulatio WIC 1 ft 0
63 ft2
----
0 1
0
' 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0
56 ft2
____
0 1
0
4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0
192 ft2
_---
0 1
0
5 Slab -On -Grade Edge Insulatio BATH 5 ft 0
45 ft2
----
0 1
0
6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0
203.5 ft2
----
0 1
0
7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0
55 ft2
----
0 1
0
4/I
/2018 3:41 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 2 of 5
G G
GnR A Rdn,,_7n17
FLOORS
:�
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
_l�
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
____
0
1
0
LI9
Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
0
1
0
IC
Slab -On -Grade
_--_
jl
ROOF
III
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
II
J
1 Gable or Shed Metal 1524 ft2
240 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
# Type Ventilation
Vent Ratio in)
Area
RBS
IRCC
i
(1
I!I
1 Full attic Vented
150
1446 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
301 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
III
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
li
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
III
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
III
lil
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
WALLS
III
Adjacent Cavity Width
Space
Height
n Et
rea
Sheathing Framing
Solar
Below
o
! 1
NE=>SW Exterior Concrete Block - Ext InsiflEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
III 2
SW=>NE Exterior Concrete Block - Ext InsIBEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.6
0
3
NW=>SE Exterior Concrete Block - Ext InsIHEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
II 4
SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.6
0
III 5
NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.6
0
II 6
NE=>SW Exterior Concrete Block - Ext InREDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.6
0
7
SE=>NW Exterior Concrete Block - Ext InMEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
�I 8
S=>N Exterior Concrete Block - Ext InEEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.6
0
IT
9
SW=>NE Exterior Concrete Block - Ext InfiffDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.6
0
i
1.0
SE=>NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
III 11
SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.6
0
12
SW=>NE Exterior Concrete Block - Ext InsLI1AUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
II 13
NE=>SW Exterior Concrete Block - Ext InsGiREAT/DINT
4.1 26
0 8
0
208.0 ft2
0
0
0.6
0
lil 14
NW=>SE Exterior Concrete Block - Ext InsGREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.6
0
4 I 15
I
N=>S Garage Frame - Wood KITCHEN
11 24
8
192.0 ft2
0.23
0.6
0
i
41
��1712018 3:41 PM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 3 of 5
it
GnR A RdnF_7nl7
DOORS
II
# Ornt
I'l
Door Type
Space
Storms U-Value Width
Ft In
Height
Ft In
Area
LL
1 SE=>NW
�Il
Insulated
ENTRY
None .39 3 1
6 8
20.6 ft2
II
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
# Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
�1I'
1 NW=>SE 3 Metal
IL 2 SW=>NE 4 Metal
1L 3 SE=>NW 7 Metal
4 NE=>SW13 Metal
III 5 NW=>SE14 Metal
III
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
0.36 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in
0.36 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in
0.36 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in
0.36 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in
0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
li
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315ft2
III
315ft2
24ft 8ft
11
1
INFILTRATION
# 'l
Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1
I', Wholehouse Proposed ACH(50) .000356
1349.6 74.09 139.34 .2598
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
II4
Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
L
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
III
Split
SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
I�
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric
I�
None
Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
II FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
Id
ft2
7/2018 3:41 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
IA RdnF-7nl7
DUCTS
---- Supply
---
---- Return
----
Air
CFM 25
CFM25
HVAC #
II # Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic 6
250 ftz
Attic
65 ftz
Default Leakage
Attic
(Default) (Default)
1 1
I
I� I
TEMPERATURES
P[,ogramable
Thermostat: Y
Ceiling Fans:
C
Hg'
II lin [[ ]] Jan Feb
tin9 [X] Jan Feb
]Mar
f X] Mar
E
A r [
Apr [
j May
] May
[X] Jun
[ ] Jun
Jul
Jul
ri
Aug
Au
ri
Se
Sep
[ ]Oct
[ ]
Oct
(]Nov
[Nov
Dec
Dec
V
tin [[ ]] Jan Feb
[[X] Mar
_�
[X
A r [
j Ma
[ ] Jun
Jul
Aug
Se
[X]
Oct
[X] Nov
Dec
Thq�mostat
Schedule: HERS 2006 Reference
Hours
Scl�ldule
Type
1
2
3
4
5
6
7
8
9
10
11
12
Co01
ing (WD) AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
I
80
80
78
78
78
78
78
78
78
78
78
78
Co
ing (WEH) AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Hea
ing (WD) AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
He
ing (WEH) AM
66
66
66
66
66
68
68
68
68
68
68
68
II. PM
68
68
68
68
68
68
68
68
68
68
66
66
7/2018 3:41 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
I .
17 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
I
ilCOMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
eneral
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
quirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
eiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
-
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
alls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
)111indows, skylights
The space between window/doorjambs and framing, and
nd doors
skylights and framing shall be sealed.
im joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
loors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
ncluding
insulation.
maintain permanent contact with the underside of
bove-garage
subfloor decking, or floor framing cavity insulation
nd cantilevered
shall be permitted to be in contact with the top side
oors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from.the
bottom to the top of all perimeter floor framing
members.
rawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls
hafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening
y P p g to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
arrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
arage separation
Air sealing shall be provided between the garage and conditioned spac
as.
ecessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
lumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind pmpong and wirmng-
t hower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
n exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
flectrical/phone box or
The air barrier shall be installed behind electrical or communication
xterior walls
boxes or air -sealed boxes shall be installed.
VAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
, oncealed
When required to be sealed, concealed fire sprinklers shall only be
prinklers
sealed in a manner that is recommended by the manufacturer.
1 I
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ceilings.
a!i In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4�I17/2018 3:41 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
I
F
1.
2.
3.
4.
5.
6.
7.
8
I co
Co
in 1
Bu
R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
FT. PIERCE, FL,
lew construction or existing
New (From Plans)
9. Wall Types
Insulation
Area
ingle family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0
192.00 ft
lumber of units, if multiple family
1
c. N/A
R=
ft2
lumber of Bedrooms
2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
s this a worst case?
Yes
a. Under Attic (Vented)
R=30.0
1446.00 ft2
:onditioned floor area (ft2)
1446
b. N/A
R=
ft2
Vindows** Description
Area
c. N/A
R=
ft2
U-Factor: Sgl, U=0.36
101.25 ft2
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ft2
6 250
SHGC: SHGC=0.25
U-Factor: Sgl, U=0.65
40.00 ft2
SHGC: SHGC=0.21
12. Cooling systems
kBtu/hr
Efficiency
U-Factor: N/A
ft2
a. Central Unit
34.8 SEER:15.00
SHGC:
U-Factor: N/A
ft2
13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Heat Pump
34.8
HSPF:8.50
rea Weighted Average. Overhang Depth:
3.832 ft.
rea Weighted Average SHGC:
0.239
loor Types
Insulation
Area
14. Hot water systems
Cap:
40 gallons
Slab -On -Grade Edge Insulation
R=0.0
1445.50 ft2
a. Electric
EF: 0.97
N/A
R=
ft2
N/A
R=
ft2
b. Conservation features
None
15. Credits
Pstat
Ify that this home has complied with the Florida Energy Efficiency Code for Building JOE ST
truction through the above energy saving features which will be installed (or exceeded) .y��
jNs home before final inspection. Otherwise, a new EPL Display Card will be completed
d on installed Code compliant featur
er Signature: Date:
less of New Home: �� ��'�.� City/FL Zip-QSLQ �.c
IT
� �'f �� WE
"Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
1**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/17/2018 3:41 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1