HomeMy WebLinkAboutENERGY EFFICIENCY CODEit
FORM R405-2017
LORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
!IProject
Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT
iSI--treet:
THE WINDSOR Permit Office: ST. LUCIE COUNTY SCANNED
city,
State, Zip: FT. PIERCE, FLU, Permit Number:
Jurisdiction: BYCough
16wner:
besign
FL, Fort Pierce County:: St. Lucie Climate Zone 2) Ste Ludo
Location: (Florida
1 New construction or existing New (From Plans)
9. Wall Types (1432.0 sqft.) Insulation Area
21 Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ft2
b. Frame - Wood, Adjacent R=11.0 208.00 ft2
3!'i Number of units, if multiple family 1
c. N/A R= ft2
41 Number of Bedrooms 3
d. N/A R= ft2
10. Ceiling Types (1753.0 sqft.) Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented) R=30.0 1753.00 ft2
6! Conditioned floor area above grade (ft2) 1753
b. N/A R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A R= ft2
11. Ducts R ft2
7. Windows(151.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic 6 265
U-Factor: Sgl, U=0.54 111.36 ft2
SHGC: SHGC=0.25
U-Factor:Sgl, U=0.55 40.00 ft 2
. .
12. Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit 34.8 SEER:15.00
U-Factor: N/A ft2
SHGC:
13. Heating systems kBtu/hr Efficiency
N/A ft2
a. Electric Heat Pump 34.8 HSPF:8.50
SHGC:
rea Weighted Average, Overhang Depth: 2.850 ft.
�1U-Factor:
rea Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric Cap: 40 gallons
8. loor Types (1753.0 sqft.) Insulation Area
EF: 0.970
Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2
b. Conservation features
N/A R= ft2
None
N/A R= ft2
I
15. Credits Pstat
1111
Total Proposed Modified Loads: 53.44
GI 'ss/Floor Area: • 0.086 PASS
Total Baseline Loads: 53.95
1 h
'� I
1 eby certify that the plans and specifications covered by
Review of the plans and O�Z$E Sx1g2�
this
calculation are in compliance with the Florida Energy
specifications covered by this y = 0�,
Co
le.
calculation indicates compliance
with the Florida Energy Code. rrrrn:''%%;j'�••.��,� Oi�
PR
DA,,
„ PA D B :'
E:
Before construction is completed ail
this building will be inspected for TL' a
compliance with Section 553.908 " l
I he 'eby certify that this building, as designed, is in compliance
Florida Statutes.
with Iihe Florida Energy C de.
O I E G N
OD WIE
BUILDING OFFICIAL:
DAIE:
DATE:
- C ,�npliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
ce ified factory -sealed in accordance with R403.3.2.1.
- Copliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
env lope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402.4.1.2).
I
FILE COPY
4/4 1018 1:52 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
'I
III
,FORM
R405-2017
II
PROJECT
1 Me: WYNNE THE WINDSOR
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1753
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
of Units: 1
Worst Case: Yes
PlatBook:
Puilder Name: WYNNE DEVELOPMENT
Rotate Angle: 225
Street:
THE WINDSOR
�jermit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Uurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
amily Type: Single-family
FL,
INew/Existing: New (From Plans)
II omment:
CLIMATE
I'I
Design Temp
Int Design Temp
Heating
Design Daily Temp
I'I Design Location TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
.III
90
70
75
299
62
Low
BLOCKS
I, Number Name Area
Volume
i
1 Entire House 1753
14024
II
SPACES
11Number Name Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 MASTER BEDROO 224
1792 No
0
1
1
Yes
Yes
Yes
WIC 63
504 No
0
1
No
Yes
Yes
I MASTER BATH 56
448 No
0
1
Yes
Yes
Yes
M.BATH 61
I4
488 No
0
1
Yes
Yes
Yes
5 LAUDRY 36
288 No
0
1
No
Yes
Yes
I¢ BEDROOM 2 180
1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREAT R 588
4704 No
2
1
Yes
Yes
Yes
8 KITCHEN 209
1672 Yes
0
1
Yes
Yes
Yes
I
BATH 50
I
400 No
0
1
Yes
Yes
Yes
0 HALL 25
i
200 No
0
1
No
Yes
Yes
li 1 FOYER 92
736 No
0
1
Yes
Yes
Yes
1112 BEDRd.OM 3 169
1352 No
0
1
1
Yes
Yes
Yes
II,
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio MASTER
BEDRO 37 ft 0
224 ft2
----
0 1
0
ll' 2 Slab -On -Grade Edge Insulatio WIC
1 ft 0
63 ft2
_---
0 1
0
II! 3 Slab Edge Insulatio MASTER
-On -Grade
4 Slab Edge Insulatio M. BATH
BATH 8 ft 0
56 ft2
----
0 1
0
-On -Grade 7 ft 0
61 ft2
----
0 1
0
II5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0
i
36 ft2
----
0 1
0
4/4/;
018 1:52 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 2 of 5
II'I
IFORM R405-2017
II,
FLOORS
11v
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 ft 0
180 ft2
----
0
1
0
7SIab-On-Grade Edge Insulatio
DINING/GREAT 50 ft 0
588 ft2
----
0
1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN 11 ft 0
209 ft2
----
0
1
0
I
9 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
50 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio
HALL 1 ft 0
25 ft2
----
0
1
0
11SIab-On-Grade Edge Insulatio
FOYER 9 ft 0
92 ft2
----
0
1
0
411—
12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 ft 0
169 ft2
----
0
1
0
i
ROOF
Roof Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
# Type Materials
Area Area
Color
Absor. Tested
Tested
Insul.
(deg)
V Hip
I'
Metal 1847 ft2 0 ft2
Light
0.6
No
0.9
No
0
18.4
fli
ATTIC
I�#
Type
Ventilation Vent Ratio in)
Area
RBS
IRCC
(1
I Full attic
Vented 150
1753 ft2
N
N
CEILING
l
# Ceiling Type
Space R-Value
Ins Type
Area
Framing Frac Truss Type
_
1 Under Attic (Vented)
MASTER BEDRO 30
Blown
224 ft2
0.1
Wood
2 Under Attic (Vented)
WIC 30
Blown
63 ft2
0.1
Wood
I�
3 Under Attic (Vented)
MASTER BATH 30
Blown
56 ft2
0.1
Wood
4 Under
Attic (Vented)
M. BATH 30
Blown
61 ft2
0.1
Wood
II
5 Under Attic (Vented)
LAUDRY 30
Blown
36 ft2
0.1
Wood
II
6 Under Attic (Vented)
BEDROOM 2 30
Blown
180 ft2
0.1
Wood
7 Under Attic (Vented)
DINING/GREAT 30
Blown
588 ft2
0.1
Wood
II
8 Under Attic (Vented)
KITCHEN 30
Blown
209 ft2
0.1
Wood
9. Under Attic (Vented)
BATH 30
Blown
50 ft2
0.1
Wood
I
i
10 Under Attic (Vented)
HALL 30
Blown
25 ft2
0.1
Wood
II
11 Under Attic (Vented)
FOYER 30
Blown
92 ft2
0.1
Wood
I'I
12 Under Attic (Vented)
BEDROOM 3 30
Blown
169 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Spacele Et In
Height
Et In
Area
Sheathing Framing
R-Vahle
Solar
Below
o
I1
NE=>W Exterior Concrete Block - Ext Ins)AASTER BE 4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
_
SW=>E Exterior Concrete Block - Ext InsMASTER BE 4.1 7
0 8
0
56.0 ft2
0
0
0.4
0
NW=>S Exterior Concrete Block - Ext InNASTER BE 4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
I
i4
i
NE=>W Exterior Concrete Block - Ext IndMASTER BA 4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
4/4/
I018
I
1:52 PM EnergyGauge®
USA - FlaRes2017 Section R405.4.1
Compliant Software
Page
3 of 5
t�l •
FORM R405-2017
WALLS
- IV
Adjacent
Cavity Width
Height
Sheathing Framing
Solar
Below
II
Space
5
NE=>W Exterior
Concrete Block - Ext InsuM. BATH
4.1 7
0
8 0
56.0 ft2
0
0
0.4
0
6
NE=>W Exterior
Concrete Block - Ext IndIffDROOM 2
4.1 12
0
8 0
96.0 ft2
0
0
0.4
0
7
SW=>E Exterior
Concrete Block - Ext IndWNING/GRE
4.1 30
0
8 0
240.0 ft2
0
0
0.4
0
8
NW-S Exterior
Concrete Block - Ext IndANING/GRE
4.1 20
0
8 0
160.0 ft2
0
0
0.4
0
9
SW=>E Exterior
Concrete Block - Ext InsuKITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.4
0
10
NE=>W Exterior
Concrete Block - Ext Insul BATH
4.1 5
0
8 0
40.0 ft2
0
0
0.4
0
11
SE=>N Exterior
Concrete Block - Ext Insul FOYER
4.1 8
0
8 0
64.0 ft2
0
0
0.4
0
12
SW=>E Exterior
Concrete Block - Ext Insul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.4
0
13
NE=>W Exterior
Concrete Block - Ext InfiffDROOM 3
4.1 13
0
8 0
104.0 ft2
0
0
0.4
0
114
SW=>E Exterior
Concrete Block - Ext InfiEDROOM 3
4.1 1
0
8 0
8.0 ft2
0
0
0.4
0
15
lil
N=>SW Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft2
0.23
0.4
0
DOORS
# Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
•
Ft In
Ft In
JI
1 SE=>N Insulated FOYER
None
.39
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
I
Wall
Overhang
# Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 NW=>S 3
Metal Low-E Single Yes
0.54 0.25
N
32.4 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2 .NE=>W 5
Metal Low-E Single Yes
0.54 0.25
N
6.9 ft2
1 ft 0 in
1 ft 4 in
None
None
3 NE=>W 6
Metal Low-E Single Yes
0.54 0.25
N
16.2 ft2
1 ft 0 in
1 ft 4 in
None
None
4 SW=>E 7
Metal Low-E Single Yes
0.54 0.25
N
39.8 ft2
1 ft 0 in
1 ft 4 in
None
None
5 NW=>S 8
Metal Low-E Single Yes
0.55 0.25
N
40.0 ft2
8 ft 0 in
1 ft 4 in
None
None
6 NE=>W.13
Metal Low-E Single Yes
0.54 ' 0.25
N
16.2 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
�I
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
#
Ii
I Scope Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 holehouse Proposed ACH(50) .000356 1636.1 89.82
168.92
.2598
7
8 1:52 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
ICI -
IF RM R405-2017
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
J!I
Electric Heat Pump/
Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
`
COOLING SYSTEM
III #
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
ICI
Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.85
1
sys#1
II
HOT WATER SYSTEM
11V #
System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1
I
Electric None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
III
Cert
# Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftZ
DUCTS
---- Supply --
---- Return
----
Air
CFM 25
CFM25
HVAC #
lil #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6 265 ftZ
Attic
55 ft2 Default Leakage
Attic
(Default) (Default)
1 1
II
TEMPERATURES
ogramable Thermostat: Y
�oling
Ceiling Fans:
C
He tinHJan
Jan [[ ]] Feb [[ ]] Mar
[X] Feb [X] Mar
[ ] Apr
[) APr
May X] Jun [X] Jul
May ] Jun [ ] Jul
[X] Aug
[ ]Au
�Xj Sep
Sepp
Oct
Oct
Nov
Nov
H
Dec
Dec
Vd tin
I
Jan [[ ]] Feb [ki Mar
[X] A r [
l
Ma [ ] Jun [ ] Jul
l
[ j Au
Se
[X]
Oct
Nov
Dec
The
mostat Schedule: HERS 2006 Reference
Hours
Schedule
Type
1
2 3
4 5 6
7
8
9
10
11
12
Coiill�ing (WD)
AM 78
78 78
78 78 78
78
78
80
80
80
80
PM 80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM 78
78 78
78 78 78
78
78
78
78
78
78
11,
PM 78
78 78
78 78 78
78
78
78
78
78
78
Hea ing (WD)
AM 66
66 66
66 66 68
68
68
68
68
68
68
1
; PM 68
68 68
68 68 68
68
68
68
68
66
66
Hea !ng (WEH)
AM 66
66 66
66 66 68
68
68
68
68
68
68
II
PM 68
68 68
68 68 68
68
68
68
68
66
66
8 1:52 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
'I •
017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
. I
Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
I
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
'General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements'The
exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
eiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
?Access openings, drop down stairs or knee wall doors to
'-unconditioned attic spaces shall be sealed.
ails
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
endows, skylights
The space between window/door jambs and framing, and
d doors
skylights and framing shall be sealed.
u�
im joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
� loors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
including
insulation.
maintain permanent contact with the underside of
ove-garage
subfloor decking, or floor framing cavity insulation
ad
cantilevered
shall be permitted to be in contact with the top side
ors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
awl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
S�afts,
penetrations
Duct shafts, utility penetrations, and flue shafts opening to
I'I
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
rrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Ds.
Icessed
lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
PI mbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind pipong and wiring.
Sqi' wer/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
orVexterior wall
tubs shall separate them from the showers and tubs.
be insulated.
EI', l ctrical/phone box o
The air barrier shall be installed behind electrical or communication
e enor walls
boxes or air -sealed boxes shall be installed.
H Ih4C register boots
HVAC register boots that penetrate building thermal envelope shall
II
be sealed to the sub -floor or drywall.
Co�p,cealed
When required to be sealed, concealed fire sprinklers shall only be
spk�nklers
sealed in a manner that is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and Mils or
auwuun, uispeo❑on or iog waus snau De in accordance with the provisions of IGG-400.
4/4/ 018 1:52 PM EnergyGaugeO USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
RM R405-2017
2.
7
8.
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
New construction or existing
Single family or multiple family
Number of units, if multiple family
Number of Bedrooms
Is this a worst case?
)nditioned floor area (ftz
'indows**
Description
U-Factor:
Sgl, U=0.54
SHGC:
SHGC=0.25
U-Factor:
Sgl, U=0.55
SHGC:
SHGC=0.25
U-Factor:
N/A
SHGC:
U-Factor:
N/A
SHGC:
ea Weighted Average Overhang Depth:
ea Weighted Average SHGC:
THE WINDSOR, FT. PIERCE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1224.00 ftz
b. Frame - Wood, Adjacent
R=11.0
208.00 ft
1
c. N/A
R=
ftz
3
d. N/A
R=
ftZ
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1753.00 ftz
1753
b. N/A
R=
ftz
Area
c. N/A
R=
ftz
111.36 ftz
11. Ducts
R ftz
a. Sup: Attic,_Ret: Attic, AH: Attic
6 265
40.00 ftz
12. Cooling systems
kBtu/hr
Efficiency
ftz
a. Central Unit
34.8 SEER:15.00
oor Types Insulation
Slab -On -Grade Edge Insulation R=0.0
N/A R=
N/A R=
ftz
13. Heating systems
kBtu/hr Efficiency
a. Electric Heat Pump
34.8 HSPF:8.50
2.850 ft.
0.250
Area
14. Hot water systems
1753.00 ft z
a. Electric
Cap: 40 gallons
EF: 0.97
ftz
ftz
b. Conservation features
None
15. Credits
Pstat
I ce ify that this home has complied with the Florida Energy Efficiency Code for Building
Co',' truction through the above energy saving features which will be installed (or exceeded)
in ts home before final inspection. Otherwise, a new EPL Display Card will be completed
bas d on installed Code compliant features.
Buil er Signature: Date:
Address of New Home: �� �,� ���� City/FL Zip:
Y
-fJJE S AT
z
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
I required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/4/2018 1:52 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1