Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEit FORM R405-2017 LORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method !IProject Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT iSI--treet: THE WINDSOR Permit Office: ST. LUCIE COUNTY SCANNED city, State, Zip: FT. PIERCE, FLU, Permit Number: Jurisdiction: BYCough 16wner: besign FL, Fort Pierce County:: St. Lucie Climate Zone 2) Ste Ludo Location: (Florida 1 New construction or existing New (From Plans) 9. Wall Types (1432.0 sqft.) Insulation Area 21 Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 3!'i Number of units, if multiple family 1 c. N/A R= ft2 41 Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1753.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1753.00 ft2 6! Conditioned floor area above grade (ft2) 1753 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(151.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 265 U-Factor: Sgl, U=0.54 111.36 ft2 SHGC: SHGC=0.25 U-Factor:Sgl, U=0.55 40.00 ft 2 . . 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: rea Weighted Average, Overhang Depth: 2.850 ft. �1U-Factor: rea Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. loor Types (1753.0 sqft.) Insulation Area EF: 0.970 Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features N/A R= ft2 None N/A R= ft2 I 15. Credits Pstat 1111 Total Proposed Modified Loads: 53.44 GI 'ss/Floor Area: • 0.086 PASS Total Baseline Loads: 53.95 1 h '� I 1 eby certify that the plans and specifications covered by Review of the plans and O�Z$E Sx1g2� this calculation are in compliance with the Florida Energy specifications covered by this y = 0�, Co le. calculation indicates compliance with the Florida Energy Code. rrrrn:''%%;j'�••.��,� Oi� PR DA,, „ PA D B :' E: Before construction is completed ail this building will be inspected for TL' a compliance with Section 553.908 " l I he 'eby certify that this building, as designed, is in compliance Florida Statutes. with Iihe Florida Energy C de. O I E G N OD WIE BUILDING OFFICIAL: DAIE: DATE: - C ,�npliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as ce ified factory -sealed in accordance with R403.3.2.1. - Copliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an env lope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402.4.1.2). I FILE COPY 4/4 1018 1:52 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 'I III ,FORM R405-2017 II PROJECT 1 Me: WYNNE THE WINDSOR Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 Block/Subdivision: of Units: 1 Worst Case: Yes PlatBook: Puilder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR �jermit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Uurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, amily Type: Single-family FL, INew/Existing: New (From Plans) II omment: CLIMATE I'I Design Temp Int Design Temp Heating Design Daily Temp I'I Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 .III 90 70 75 299 62 Low BLOCKS I, Number Name Area Volume i 1 Entire House 1753 14024 II SPACES 11Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes WIC 63 504 No 0 1 No Yes Yes I MASTER BATH 56 448 No 0 1 Yes Yes Yes M.BATH 61 I4 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes I¢ BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes I BATH 50 I 400 No 0 1 Yes Yes Yes 0 HALL 25 i 200 No 0 1 No Yes Yes li 1 FOYER 92 736 No 0 1 Yes Yes Yes 1112 BEDRd.OM 3 169 1352 No 0 1 1 Yes Yes Yes II, FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft2 ---- 0 1 0 ll' 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 _--- 0 1 0 II! 3 Slab Edge Insulatio MASTER -On -Grade 4 Slab Edge Insulatio M. BATH BATH 8 ft 0 56 ft2 ---- 0 1 0 -On -Grade 7 ft 0 61 ft2 ---- 0 1 0 II5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 i 36 ft2 ---- 0 1 0 4/4/; 018 1:52 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 II'I IFORM R405-2017 II, FLOORS 11v # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ---- 0 1 0 7SIab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 ---- 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN 11 ft 0 209 ft2 ---- 0 1 0 I 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 ---- 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 ---- 0 1 0 411— 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 ---- 0 1 0 i ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) V Hip I' Metal 1847 ft2 0 ft2 Light 0.6 No 0.9 No 0 18.4 fli ATTIC I�# Type Ventilation Vent Ratio in) Area RBS IRCC (1 I Full attic Vented 150 1753 ft2 N N CEILING l # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood I� 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood II 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood II 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood II 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 9. Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood I i 10 Under Attic (Vented) HALL 30 Blown 25 ft2 0.1 Wood II 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood I'I 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS Adjacent Cavity Width Spacele Et In Height Et In Area Sheathing Framing R-Vahle Solar Below o I1 NE=>W Exterior Concrete Block - Ext Ins)AASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 _ SW=>E Exterior Concrete Block - Ext InsMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.4 0 NW=>S Exterior Concrete Block - Ext InNASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 I i4 i NE=>W Exterior Concrete Block - Ext IndMASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 4/4/ I018 I 1:52 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 t�l • FORM R405-2017 WALLS - IV Adjacent Cavity Width Height Sheathing Framing Solar Below II Space 5 NE=>W Exterior Concrete Block - Ext InsuM. BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.4 0 6 NE=>W Exterior Concrete Block - Ext IndIffDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.4 0 7 SW=>E Exterior Concrete Block - Ext IndWNING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.4 0 8 NW-S Exterior Concrete Block - Ext IndANING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 9 SW=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 10 NE=>W Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 11 SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 12 SW=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 13 NE=>W Exterior Concrete Block - Ext InfiffDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0 114 SW=>E Exterior Concrete Block - Ext InfiEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 15 lil N=>SW Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area • Ft In Ft In JI 1 SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. I Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.54 0.25 N 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 .NE=>W 5 Metal Low-E Single Yes 0.54 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.54 0.25 N 16.2 ft2 1 ft 0 in 1 ft 4 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.54 0.25 N 39.8 ft2 1 ft 0 in 1 ft 4 in None None 5 NW=>S 8 Metal Low-E Single Yes 0.55 0.25 N 40.0 ft2 8 ft 0 in 1 ft 4 in None None 6 NE=>W.13 Metal Low-E Single Yes 0.54 ' 0.25 N 16.2 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 �I GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION # Ii I Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 holehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2598 7 8 1:52 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 ICI - IF RM R405-2017 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 J!I Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 ` COOLING SYSTEM III # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 ICI Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 II HOT WATER SYSTEM 11V # System Type SubType Location EF Cap Use SetPnt Conservation 1 I Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage III Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftZ DUCTS ---- Supply -- ---- Return ---- Air CFM 25 CFM25 HVAC # lil # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 265 ftZ Attic 55 ft2 Default Leakage Attic (Default) (Default) 1 1 II TEMPERATURES ogramable Thermostat: Y �oling Ceiling Fans: C He tinHJan Jan [[ ]] Feb [[ ]] Mar [X] Feb [X] Mar [ ] Apr [) APr May X] Jun [X] Jul May ] Jun [ ] Jul [X] Aug [ ]Au �Xj Sep Sepp Oct Oct Nov Nov H Dec Dec Vd tin I Jan [[ ]] Feb [ki Mar [X] A r [ l Ma [ ] Jun [ ] Jul l [ j Au Se [X] Oct Nov Dec The mostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Coiill�ing (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 11, PM 78 78 78 78 78 78 78 78 78 78 78 78 Hea ing (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 1 ; PM 68 68 68 68 68 68 68 68 68 68 66 66 Hea !ng (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 II PM 68 68 68 68 68 68 68 68 68 68 66 66 8 1:52 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 'I • 017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA . I Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce I COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA 'General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements'The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. eiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. ?Access openings, drop down stairs or knee wall doors to '-unconditioned attic spaces shall be sealed. ails The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. endows, skylights The space between window/door jambs and framing, and d doors skylights and framing shall be sealed. u� im joists Rim joists shall include the air barrier. Rim joists shall be insulated. � loors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to including insulation. maintain permanent contact with the underside of ove-garage subfloor decking, or floor framing cavity insulation ad cantilevered shall be permitted to be in contact with the top side ors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. awl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. S�afts, penetrations Duct shafts, utility penetrations, and flue shafts opening to I'I exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow rrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Ds. Icessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. PI mbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pipong and wiring. Sqi' wer/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall orVexterior wall tubs shall separate them from the showers and tubs. be insulated. EI', l ctrical/phone box o The air barrier shall be installed behind electrical or communication e enor walls boxes or air -sealed boxes shall be installed. H Ih4C register boots HVAC register boots that penetrate building thermal envelope shall II be sealed to the sub -floor or drywall. Co�p,cealed When required to be sealed, concealed fire sprinklers shall only be spk�nklers sealed in a manner that is recommended by the manufacturer. I Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and Mils or auwuun, uispeo❑on or iog waus snau De in accordance with the provisions of IGG-400. 4/4/ 018 1:52 PM EnergyGaugeO USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 RM R405-2017 2. 7 8. ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. New construction or existing Single family or multiple family Number of units, if multiple family Number of Bedrooms Is this a worst case? )nditioned floor area (ftz 'indows** Description U-Factor: Sgl, U=0.54 SHGC: SHGC=0.25 U-Factor: Sgl, U=0.55 SHGC: SHGC=0.25 U-Factor: N/A SHGC: U-Factor: N/A SHGC: ea Weighted Average Overhang Depth: ea Weighted Average SHGC: THE WINDSOR, FT. PIERCE, FL, New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ftz b. Frame - Wood, Adjacent R=11.0 208.00 ft 1 c. N/A R= ftz 3 d. N/A R= ftZ 10. Ceiling Types Insulation Area Yes a. Under Attic (Vented) R=30.0 1753.00 ftz 1753 b. N/A R= ftz Area c. N/A R= ftz 111.36 ftz 11. Ducts R ftz a. Sup: Attic,_Ret: Attic, AH: Attic 6 265 40.00 ftz 12. Cooling systems kBtu/hr Efficiency ftz a. Central Unit 34.8 SEER:15.00 oor Types Insulation Slab -On -Grade Edge Insulation R=0.0 N/A R= N/A R= ftz 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.8 HSPF:8.50 2.850 ft. 0.250 Area 14. Hot water systems 1753.00 ft z a. Electric Cap: 40 gallons EF: 0.97 ftz ftz b. Conservation features None 15. Credits Pstat I ce ify that this home has complied with the Florida Energy Efficiency Code for Building Co',' truction through the above energy saving features which will be installed (or exceeded) in ts home before final inspection. Otherwise, a new EPL Display Card will be completed bas d on installed Code compliant features. Buil er Signature: Date: Address of New Home: �� �,� ���� City/FL Zip: Y -fJJE S AT z *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. I required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/4/2018 1:52 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1