HomeMy WebLinkAboutENERGY EFFICIENCY CODEF RM R405,-2017
F'�� ORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Flbrida Department of Business and Professional Regulation - Residential Performance Method
Pr
'ect Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT SC
St
et: THE STERLING Permit Office: ST. LUCIE COUNTY QM°V
g�" `DEL)
V
Ci
O
, State, Zip: FT. PIERCE , FL , Permit Number: f. /�i
�
�I�ner: �S�G ��✓� q Jurisdiction: 011(90my
c�
D
gn Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2)
�i
1
w construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.) Insulation Area
2. Si
gle family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2
3.
mber of units, if multiple family 1
b. Frame - Wood, Adjacent R=11.0 192.00 ft2
c. N/A
I
R= ft2
4.
mber of Bedrooms 2
d. N/A R= ft2
5. IQ
this a worst case? Yes
10. Ceiling Types (1474.0 sqft.) Insulation Area
a. Under Attic (Vented) R=30.0 1474.00 ft2
6. C'
nditioned floor area above grade (ft2) 1474
b. N/A R= ft2
C
nditioned floor area below grade (ft2) 0
c. R= ft2
11. Ducts R ft2
7.
indows(141.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic 6 300
a:
U-Factor: Sgl, U=0.63 101.25 ft2
SHGC: SHGC=0.25
b!
U-Factor: Sgl, U=0.65 40.00 ft2
12. Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit 34.8 SEER:15.00
c:
U-Factor: N/A ft2
SHGC:
13. Heating systems kBtu/hr Efficiency
d!
U-Factor: N/A ft2
a. Electric Heat Pump 34.8 HSPF:8.50
SHGC:
A
Aa
a Weighted Average Overhang Depth: 3.832 ft.
Weighted Average SHGC: 0.239
14. Hot water systems
8. F10orTypes
(1473.5 sqft.) Insulation Area
a. Electric Cap: 40 gallons
a'
lab -On -Grade Edge Insulation R=0.0 1473.50 ft2
EF: 0.970
b. Conservation features
bl
/A R= ft2
None
c!
/A R= ft2
15. Credits Pstat
Gla
is/Floor Area: 0.096 Total Proposed Modified Loads: 48.34 PASS
Total Baseline Loads: 48.53
I he
b certify that the plans and specifications covered b
y fy p p y
Review of the plans and �T HE S�
this Ii
i
culation are in compliance with the Florida Energy
specifications covered by this
Cod,calculation
indicates compliance ri,, 'T = S
";, �O
with the Florida Energy Code. ti rrr„(��•;'�°�
PR I
DA
PAR B
E: A
Before construction is completed w p v
this building will be inspected for i y
compliance with Section 553.908 * °
I he
by certify that this building, as designed, is in compliance
Florida Statutes.
with
he Florida Energy Code.
G'OD WE
OW
ER JIT
BUILDING OFFICIAL:
DATE:
- Copliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
ce tified factory -sealed in accordance with R403.3.2.1.
- Co ipiiance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
env' ope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FILE COPY
4/1' /2018 12:27 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM
R405-2017
'
PROJECT
Til
le: ' WYNNE THE STERLING Bedrooms: 2
Address Type:
Street Address
B I
Iding Type: User
Conditioned Area: 1474
Lot #
OI
ner Name:
Total Stories: 1
Block/Subdivision:
#
f Units: 1
Worst Case: Yes
PlatBook:
B
Ider Name: WYNNE DEVELOPMENT Rotate Angle: 180
Street:
THE STERLING
Pe
-mit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Julisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
F
ily Type: Single-family
FL,
Ne
/Existing: New (From Plans)
CII
ment:
CLIMATE
?I
Design Temp
Int Design Temp Heating
Design Daily Temp
�
Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH _MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
Entire House
1474 11792
SPACES
umber Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
BEDROOM
329 2632 No
0
1
1 Yes
Yes
Yes
WIC
63 504 No
0
1 No
Yes
Yes
M.BATH
56 448 No
0
1 Yes
Yes
Yes
KITCHEN
192 1536 Yes
0
1 No
Yes
Yes
BATH
45 360 No
0
1 Yes
Yes
Yes
BEDROOM 2
204 1632 No
0
1
1 Yes
Yes
Yes
ENTRY
55 440 No
0
1 Yes
Yes
Yes
LAUNDRY
42 336 No
0
1 Yes
Yes
Yes
GREAT/DINING
488 3904 No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
329 ft2
_-__
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ft2
_---
0 1
0
3 Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ft2
____
0 1
0
4Slab-On-Grade Edge Insulatio
KITCHEN 1 ft 0
192 ft2
-_--
0 1
0
5 Slab -On -Grade Edge Insulatio
9
BATH 5 ft 0
2
45 ft2
____
0 1
0
6 Slab -On -Grade Ede Insulatio
9
BEDROOM 2 32.2 ft 0
2 2
03.5 ft2
____
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 7 ft 0
55 ft2
----
0 1
0
4/1, II /2018 12:27 PM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 2 of 5
FOR' R405-2017
'
FLOORS
�'- # Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
----
0
1
0
ROOF
I% Roof
Gable
Roof
Solar
SA
Emitt
Emitt
Deck
Pitch
# Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Gable or Shed Metal 1553 ft2
246 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
i
# Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1474 ft2
N
N
CEILING
, # Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
329 ft2
0.1
Wood
I
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
li
30
Blown
488 ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width
RAW-- Et In
Height
Et In
Area
Sheathing Framing
RAIM-le Eract*on
Solar
Ahsor
Below
rrqrle%
1 NE=>SW Exterior Concrete Block - Ext Ins(dEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
i
� 2 SW=>NE Exterior Concrete Block - Ext InsI1HEDROOM
4.1 28 -
0 8
0
224.0 ft2
0
0
0.6
0
3 NW=>SE Exterior Concrete Block - Ext InsiHEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.6
0
5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.6
0
6 NE=>SW Exterior Concrete Block - Ext InQEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.6
0
7 SE=>NW Exterior Concrete Block - Ext In&EDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
8 S=>N Exterior Concrete Block - Ext InfiffDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.6
0
119 SW=>NE Exterior Concrete Block - Ext IndIffDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.6
0
�110 SE=>NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
1 SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.6
0
-,
2 SW=>NE Exterior Concrete Block - Ext InsaLAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
_i
3 NE=>SW Exterior Concrete Block - Ext InsGiREAT/DINT
4.1 26
0 8
0
208.0 ft2
0
0
0.6
0
4 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.6
0
5 N=>S Garage Frame - Wood KITCHEN
11 24
8
192.0 ft2
0.23
0.6
0
44 /2018 12:27 PM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 3 of 5
i.
l npm RAns;-gf117
•
DOORS
�I # Ornt
Door Type
Space
Storms U-Value Width
Ft In
Height
9
Ft In
Area
1 SE=>NW
I I
Insulated
ENTRY
None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
I, Wall
# Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
II 3 SE=>NW 7 Metal
I,I 4 NE=>SW13 Metal
5 NW=>SE14 Metal
T
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
0.63 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in
0.63 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in
0.63 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in
0.63 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in
0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315ft2
_71-
315ft2
24ft 8ft
11
INFILTRATION
#
I' Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1
Wholehouse Proposed ACH(50) .000356
1375.7 75.53 142.04 .2598
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
L�
1 Electric Heat Pump/
Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.85 1
sys#1
II
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric
I
None
Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume FEF
it
None None
ft2
7/2018 12:27 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FOR R405-2017
'
DUCTS
j
-- Supply
—
-- Return
--
Air
CFM 25
CFM25
HVAC #
# Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6
300 ft2
Attic
75 ft2
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Pl
�I gramable Thermostat: Y
Ceiling Fans:
Co
He
lingJan
it f X Jan
Feb
Feb
Mar
Mar
ki
A r
Apr I
Ma
May
[X Jun
j Jun
Jul
Jul
ri
Au
AuI
ri
X Se
Sep
[ ]Oct
[ ]
Oct
[ Nov
[X� Nov
[ ]Dec
X] Dec
VeItin
[ Jan
Feb
Mar
[X
Apr
May
E Jun
Jul
Aug
Se
[X]
Oct
[X Nov
j Dec
The��
ostat Schedule:
HERS 2006 Reference
Hours
Schrule
Type
1
2
3
4
5
6
7
8
9
10
11
12
Coo
ng (VVD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
l
PM
80
80
78
78
78
78
78
78
78
78
78
78
Coo
ng (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Hea'ng(WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Hea
(WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
ling
PM
68
68
68
68
68
68
68
68
68
68
66
66
4/1 p,/2018 12:27 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
2 ) 17 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT
Street: THE STERLING Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
-11
neral
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
r,
quirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
iling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
ails
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
skylights
The space between window/door jambs and framing, and
:indows,
�Pd doors
skylights and framing shall be sealed.
l 11
im joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
oors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
( cluding
insulation.
maintain permanent contact with the underside of
Dove -garage
subfloor decking, or floor framing cavity insulation
id cantilevered
shall be permitted to be in contact with the top side
oors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
rawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation .
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
hafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
arrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
r
arage separation
Air sealing shall be provided between the garage and conditioned spac
3s.
f Iecessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Iumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring
hower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
lectrical/phone box or
The air barrier shall be installed behind electrical or communication
error walls
boxes or air -sealed boxes shall be installed.
VAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
oncealed
When required to be sealed, concealed fire sprinklers shall only be
rinklers
sealed in a manner that is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be used to fill voids
between fire sormnkler cover plates and walls or ceilings- I
a Inj auuujun, ujspeajon of jog watts snail de in accordance with the provisions of !CC-400.
4 17/2018 12:27 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
aFOi' M R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
THE STERLING, FT. PIERCE, FL,
1. ISI
w construction or existing
New (From Plans)
9. Wall Types
Insulation
Area
2. Ingle
family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1250.00 ftZ
b. Frame - Wood, Adjacent
R=11.0
192.00 ft
3.
mber of units, if multiple family
1
c. N/A
R=
ft2
4.
mber of Bedrooms
2
d. N/A
R=
ftZ
5. I'
this a worst case?
Yes
10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
1474.00 ftz
6. :
onditioned floor area (ftz)
1474
b. N/A
R=
ftz
7. 1 I
indows** Description
Area
c. N/A
R=
ftz
a
U-Factor: Sgl, U=0.63
101.25 ftz
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ftz
6 300
i
SHGC: SHGC=0.25
b
U-Factor: Sgl, U=0.65
40.00 ftz
SHGC: SHGC=0.21
12. Cooling systems
kBtu/hr
Efficiency
6.1
U-Factor: N/A
ftz
a. Central Unit
34.8 SEER:15.00
SHGC:
c.
U-Factor: N/A
ftz
SHGC:
13. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
34.8
HSPF:8.50
ea Weighted Average Overhang Depth:
3.832 ft.
A,
ea Weighted Average SHGC:
0.239
8. 1 loor
Types
Insulation
Area
14. Hot water systems
Cap:
40 gallons
Slab -On -Grade Edge Insulation
R=0.0
1473.50 ftz
a. Electric
N/A
EF: 0.97
c.
N/A
R=
R=
ftz
ftz
b. Conservation features
None
15. Credits
Pstat
I ceqfy that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in thhome before final inspection. Otherwise, a new EPL Display Card will be completed
bas � on installed Code compliant features. r1 1
Buil - Lr Signature: ���� Date:
Add'' ss of New Home: ���� Vic, City/FL Zip7N �-�
-04
E SrA��p�
WS
Vote: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
iortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
,chsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
grtified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
ommission's support staff.
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/17/2018 12:27 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1