Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEI , ORM R405-2017 } ; LORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method roject Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT treet: THE STERLING Permit Office: ST. LUCIE COUNTY QtitY,State, Zip: ET. PI RC�Vv Permit Number: 1 caner: � Jurisdiction: Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1.i New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 ' 1250.00 ft2 I d b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Lumber of Bedrooms 2 d. N/A R= ft2 5. this a worst case? Yes 10. Ceiling Types (1474.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1474.00 ft2 Its 6. onditioned floor area above grade (ft2) 1474 b. N/A R= ft2 I onditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. ! indows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 300 U-Factor: Sgl, 11=0.63 101.25 ft2 SHGC: SHGC=0.25 U-Factor: Sgl, U=0.65 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: ea Weighted Average Overhang Depth: 3.832 ft. ! rea Weighted Average SHGC: 0.239 14. Hot water systems 8. �loor II Types (1473.5 sqft.) Insulation Area a. Electric Cap: 40 gallons i a. � Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2 b. Conservation features EF: 0.970 till N/A R= ft2 None c I N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 48.34 PASS GI�ss/Floor Area: 0.096 Total Baseline Loads: 48.53 I he�eby certify that the plans and specifications covered by Review of the plans and ol4E SrA?, this alculation are in compliance with the Florida Energy specifications covered by this �� __ - ;�0Sr �, Cod . calculation indicates compliance with the Florida Energy Code. rnu rfr��% •.:�; °;�. „ O PR PA "BY' DA E: Before construction is completed this building will be inspected for compliance with Section 553.908 he).' by certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'Op WE�� OW ERNUT- BUILDING OFFICIAL: DAl DATE: l - CoTpliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as ce ' ified factory -sealed in accordance with R403.3.2.1. - Co pliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an enve ope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). �FILE COPY 4/4/ 018 10:16 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 III' , .ill FdRM R405-2017- PROJECT itle: WYNNE THE STERLING Bedrooms: 2 Address Type: Street Address I uilding Type: User Conditioned Area: 1474 Lot # Owner Name: Total Stories: 1 Block/Subdivision: of Units... 1 Worst Case: Yes PlatBook: uilder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING �?ermit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie II�Illiurisdictiom Whole House Fan: No City, State, Zip: FT. PIERCE, amity Type: Single-family New/Existing: FL, New (From Plans) omment: CLIMATE II / Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 ,II ' 90 70 75 299 62 Low II BLOCKS IIIINumber Name Area Volume 1 Entire House 1474 11792 II SPACES 11"Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes WIC 63 504 No 0 1 No Yes Yes .3 M.BATH 56 448 No 0 1 Yes Yes Yes KITCHEN 192 1536 Yes 0 1 No Yes Yes BATH 45 360 No 0 1 Yes Yes Yes BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes ENTRY 55 440 No 0 1 Yes Yes Yes LAUNDRY 42 336 No 0 1 Yes Yes Yes GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS J # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft2 ---- 0 1 0 2 Slab Edge Insulatio WIC -On -Grade il 1 ft 0 63 ft2 ---- 0 1 0 .3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft2 ---- 0 1 0 'III 7Slab-On-Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 __-- 0 1 0 4/4' 018 10:16 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 11 FORM R405-2017 'i F FLOORS ,, # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile t Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 0 1 0 II ---- I ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) I 1 Gable or Shed Metal 1553 ftZ 246 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC ill # Type Ventilation Vent Ratio in) Area RBS IRCC (1 I� 1 Full attic Vented 150 1474 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft2 0.1 Wood i� 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 1I 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood I' 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood it 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood II WALLS It Adjacent Cavity Width Orint 10 Wall Type SpaceArea Height Sheathing Framing R-Valtle Solar Below Ij 1 NE=>SW Exterior Concrete Block - Ext InsiBEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext InsiflEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext InsfHEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 1 6 it NE=>SW Exterior Concrete Block - Ext InfiIEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE -NW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext InMDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext InRffDR00M 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 . 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 i I 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 112 SW=>NE Exterior Concrete Block - Ext Insd]AUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext Ins6REAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 I,14 NW=>SE Exterior Concrete Block - Ext lnsGREAT/DINT 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 15 N=>S Garage Frame -Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 li II 41 018 10:16 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 .II FORM R405-2017 DOORS i # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area i9 4 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 II WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall l # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening i 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 `•SE=>NW 7 Metal 4 .NE=>SW13 Metal 5 NW=>SE14 Metal I ' Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 0.63 0.25 N 32.9 ft' 1 ft 0 in 1 ft 4 in 0.63 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in 0.63 '0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in 0.63 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in 0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 I GARAGE IV # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation ILI 1 315ft2 315ft2 24ft 8ft 11 I' INFILTRATION I # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 �I Wholehouse Proposed ACH(50) .000356 1375.7 75.53 142.04 .2598 7 I' HEATING SYSTEM v # System Type Subtype Efficiency Capacity Block Ducts I .1 Electric Heat Pump/ Split II HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ II Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation I 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None lil ft2 8 10:16 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 DUCTS II / ---- Supply -- ---- Return ---- Air CFM 25 CFM25 HVAC # 4 �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 300 ftZ Attic 75 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES D rogramable Thermostat: Y Ceiling Fans: iI (polingJan HJan Feb HFeb Mar Mar [ [ ] Apr [ Apr[ Ma j May [[X]] Jun [ ] Jun [X] Jul [ ] Jul [ ] Au rj AugJXJ Se Sep r [ Oct Oct Nov Nov HX Dec Dec H Jan Feb X Mar [X] A r [ Ma [ j Jun [ ] Jul [ ]] Au Se [[[XXX Oct Nov Dec T 'ermostat Schedule: HERS 2006 Reference Hours S �edule Type 1 2 3 4 5 6 7 8 9 10 11 12 C' oling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cc oling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 He' sating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 ,i PM 68 68 68 68 68 68 68 68 68 68 66 66 H,ating(WEH) ail AM PM 66 66 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 8 10:16 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 I017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA it Project Name: WYNNE THE STERLING Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce �I COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA eneral A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall equirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. eiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. I' Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with i sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. IiVindows, skylights The space between window/doorjambs and framing, and 4d doors skylights and framing shall be sealed. ri F im joists Rim joists shall include the air barrier. Rim joists shall be insulated. 00rs Iml. The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to ding insulation. maintain permanent contact with the underside of above -garage aiid cantilevered subfloor decking, or floor framing cavity insulation shall be to be in contact with the top fl permitted side ors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation ;II a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. afts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow N arrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. G rage separation Air sealing shall be provided between the garage and conditioned spac as. Rlcessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building i shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. PI mbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pipong and wiring Sf�'ower/tub on exterior wall The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall tubs shall separate them from the showers and tubs. be insulated. EI Ictrical/phone box o The air barrier shall be installed behind electrical or communication e erior walls boxes or air -sealed boxes shall be installed. WA' C register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed cealed When required to be sealed, concealed fire sprinklers shall only be spt nklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids ates and walls or cemlonaa Il�rwwll vl Ivy vvcII0 aucu va III auuulud[IL& wlUl Ine PrOVISIOrIS Oi JUU-41.11J. 4/4/ 018 10:16 AM EnergyGaugeg) USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 El �R'm R405-2017 01 7 in Bu ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. aw construction or existing ngle family or multiple family umber of units, if multiple family umber of Bedrooms this a worst case? :)nditioned floor area (ft2 'indows** Description U-Factor: Sgl, U=0.63 SHGC: SHGC=0.25 U-Factor: Sgl, U=0.65 SHGC: SHGC=0.21 U-Factor: N/A SHGC: U-Factor: N/A SHGC: ea Weighted Average Overhang Depth: ea Weighted Average SHGC: oor Types Slab -On -Grade Edge Insulation N/A N/A THE STERLING, FT. PIERCE, FL, New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block- Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 1 c. N/A R= ft2 2 d. N/A R= ft2 10. Ceiling Types Insulation Area Yes a. Under Attic (Vented) R=30.0 1474.00 ft2 1474 b. N/A R= ft2 c. N/A R= ft2 Area 11. Ducts R ft2 101.25Area ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 300 40.00 ft2 12. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 34.8 SEER:15.00 ft2 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.8 HSPF:8.50 3.832 ft. 0.239 Insulation Area 14. Hot water systems Cap: 40 gallons R=0.0 1473.50 ft2 a. Electric EF: 0.97 R= ft2 R= ft2 b. Conservation features None 15. Credits Pstat ify that.this home has complied with the Florida Energy Efficiency Code for Building struction through the above energy saving features which will be installed (or exceeded) is home before final inspection. Otherwise, a new EPL Display Card will be completed A on installed Code compliant features. IJer Signature: - Date: �ess of New Home: City/FL Zi 126 1-� S �;k *Note:: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. lI **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/4/2018 10:16 AM EnergyGauge@ USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1