Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL - ROOF DECK��AAIANVFZ Mlfl6 8/ 6/2018 / / h A - IAA //I / %%/ ililding Code Online AeA- 14l��Lj- b. BCIS Home I Log In I User Registration Hot Topics Submit Surcharge Stats & Facts i Publications Contact Us BCIS Site Map, Links Search rt} Product Approval Ia USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail V� ® FL # F,0346-R'4.. , Application Type Revision Code Version 2017 Application Status Approved ®4/0 Comments yl� Archived U Product Manufacturer aVulcan SteeC StructuGes, Inc• (1 Address/Phone/Email 500 Vulcan Parkway Adel, GA 31620 (229) 896-7903 Ext231 jeffs@vulcansteel.com Authorized Signature Jeff Spradley jeffs@vulcansteel.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Structural Components Subcategory Roof Deck Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer CD Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Terrence E. Wolfe Evaluation Report Florida License PE-44923 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 09/27/2024 Validated By Brian Jaks, P.E. (!6 Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL5346 R4 COI Letter of Certification secured.pdf 1 Standard Year ASTM E 1592 2005 FM 4471 1992 File Copy Product Approval Method Method 1 Option D ig.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsHSnAT%2fMPHLL9%2f rSM%2biefrTHQVJhnOYok°/a3d 1 /2 8/16/2018 Florida Building Code Online Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products 09/26/2017 09/30/2017 10/03/2017 12/12/2017 FL # Model, Number or Name Description 5346.1'P-BRsRoof-pahel�j 26 Ga. PBR Roof Panel over open framing Non-HVHZ Limits of. Use Installation Instructions Approved for use in HVHZ: No FL5346 R4 II PBR Structural Roof Panel NON HVHZ secured.pdf Approved for use outside HVHZ: Yes Impact.Resistant: N/A Verified By: Terrence E. Wolfe, P.E. 44923 Desig). 'Pressure: +50.OPSF/-165.OPSF Created by Independent Third Party: Yes Other: 45.0 PSF @ 5'-0" o.c. fastener spacing. +50.0 psf @ Evaluation Reports 5'-0" o.c. fastener spacing. -72.5 psf @ 5'-0" D.C. fastener FL5346 R4 AE PBR Structural Roof Panel NON HVHZ- secured.pdf spacing. -165.0 psf @ 2'-0" c.c. fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO.employer. Copy.Light 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement I Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please) provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here , i Product Approval Accepts: I ®� ® e C � M Credit Card Safe 6 hftps://www.floridabuilding.org/pr/praPP_dtl.as x? aram=wGEVXQwtD sHSnATo/a2fMPHLL90/o2fTSM0/o2biefFTHQVJhnOYok0/a3d 2/2 FL# 5346.1. R4 rFogrcegineering & Testing Inc. 19530 Ramblewood Drive Humble,TX 77338 Product Evaluation Report VULCAN STEEL STRUCTURES, INC. 26 Ga. PBR Roof Panel over open framing Florida Product Approval # 5346.1 R4 Florida Building Code 2017 Per Rule 61G20-3 Method: 1—D Category: Structural Components Subcategory: Roof Deck Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Vulcan Steel Structures, Inc. 500 Vulcan Parkway Adel, GA 31620 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID: 1920 Validator• Brian Jaks P.E. #70159 Contents: Evaluation Report Pages 1-4 STATE OF ; a t� 4% � aW. FZORIIDp''�4,�, i 'O�Ill on September 26, 2017 Force Engineering & Testing Inc. 19530 Ramblewood Drive Humble,TX 77338 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2, 1504.7. Product Description: PBR Roof Panel, 26 Ga. Steel, 36" Wide, through fastened structural roof panel. Structural Application. Panel Material/Standards: Material: 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Yield Strength: Min. 80.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 0.0185" min. Width: 36" maximum coverage Rib Height: 1-1/4" major rib at 12" O.C. Panel Rollformer: A.S.C. Machine Tools, Inc. Panel Fastener: #12-14 x 1-1/4" HWH SD with sealing washing or approved equal. Panel side laps fastened together w/ %-14 x 7/8" HWH SD w/ sealer washer at 20" O.C. Corrosion Resistance: Per Florida Building Code 2017, Section 1507.4.4. Substrate Description: Min. 16 Ga. Steel Framing. Framing must be designed in accordance w/ Florida Building Code 2017. Allowable Design Pressures: FL# 5346.1 R4 Table "A" Maximum Design Pressure: -45.0 psf +50.0 psf -72.5 psf -165.0 psf Fastener Pattern: 12"-12"-12" 12"-12"-12" 7"-5"-7"-5"-7" 7"-5"-7"-5"-7" Fastener Spacing: 5'-0" O.C. 5'-0" O.C. 5'-0" O.C. 2'-0" O.C. *Design Pressure includes a Safety Factor = 2.0 ,`,,�{1111IfIl��I � �`v• No.46➢ •� � r •� STATE OF : qC GDAL owm smaofFlom. ,, 1P� 0�1111{� ♦�, �� September 26, 2017 Force Entgincering & Testing Inc. J9530 Ramblewood Drive Humble,TX 77338 Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2017, Section 1504.3.2, 1504.7. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: ■ ASTM E 1592-05 (2012) Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference. ■ FM 4471-92, Foot Traffic Resistance Test. Reference Data: 1. ASTM E 1592-01 Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 155-0258T-08, dated 07/22/2008 2. ASTM E 1592-01 Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 155-0300T-11, dated 01/04/2012 3. FM 4471-10, Section 4.4 Foot Traffic Resistance Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 155-0336T-11A, Dated 01/04/2012 4. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization # ANE ID: 1920) Test Standard Equivalency: The ASTM E 1592-01 test standard is equivalent to ASTM E 1592-05(2012) The FM 4471-10, Foot Traffic Resistance test standard is equivalent to FM 4471-92. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. FL# 5346.1 R4 "111s11110stj NO. 4499 STATE OF '0 0 tv . September 26, 2017 Force Engineering & Testing Inc. 19530 Ramblewood Drive .Humble,TX 77338 Installation: Install per manufacturer's recommended details. Insulation: Manufacturer's approved product (Optional) Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2017 Chapter 22 for steel, and Chapter 16 for structural loading. `,�ttr,ts�rirri��i S E N STATE OF ; a 0 R 1 sa� m ,, j,"OM41 rr15trtt��,,, FL# 5346.1 R4 September 26, 2017 1 1/4" VULCAN STEEL STRUCTURES, INC. 26 GA. PBR ROOF PANELS 36" PANEL 12"-12"-12" FASTENER PATTERN 1/4-14 X 7/8 LAP SCREW 12' 12" 12" ® 20' O.C. � #12-14 x 1 1/4' HWH w/ SEALER WASHER TAPE SEALANT SLOPES LESS THAN 3:12 PANEL 7"-5"-?"-5'-7' FASTENER PATTERN --- 1/4-14 X 7/8 LAP SCREW 5" 7' 5' 7" 5' 7" 1 m 20' O.C. T #12-14 x 1 1/4" HWH w/ SEALER WASHER TAPE SEALANT SLOPES LESS THAN 3:12 C.OA x�t e� 7 S 15 p 83sQ2 1� 2677S _ �y��t��vL �,• �yeBP'�a p 1 ooc.. O `• O • GG pp 9 4 «0.' 2 p • ; • ,^ - F. rc Al ec`;••��e R �vIlicttes°e September 26, 2017