Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL - SWINGING EXTERIOR DOOR8/1 2018 4/~,V W PEZ /1, , &C:6 �' Florida Building. Code Online TIP Professimll Regulation BCIS Home I Log In User Registration Hot Topics Submit Surcharge Stats.& Facts Publications Contact Us �• BCIS Site Map, Links 'Search j 'I r�s Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL222'ir1,-l€1 Application Type Affirmation Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By ff *"'Tell Manufacturing;Ine:, i 207 Bucky Drive Lititz, PA 71543 (949) 672-4372 pablo.munoz@spectrumbrands.com Pablo Munoz pablo.munoz@spectrumbrands.com Exterior Doors Swinging Exterior Door Assemblies Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer L Evaluation Report - Hardcopy Received Robert 1. Amoruso, PE PE-49752 Architectural Testing, Inc., an Intertek Company 12/31/2018 Steven M. Urich, PE 0 Validation Checklist - Hardcopy Received FL22211 R1 COI CertOfInd 415-1207 TiogaDoorwaySystem- TelestarProDoor ss.pdf Standard Year ASTM E283-04 2004 ASTM E330-02 2002 ASTM E331-00(2009) 2009 TAS 201 ' 1994 TAS 202 1994 TAS 203 1994 �i1e C® V Florida Licensed Professions ngineer or ArcTitect FL22211 R1 Equiv PERNo2490 RevO 415- 1207 TiogaDoorwaySystem ss.pdf _app_dtl.aspx?param=wGEVXQwtDquYPIHVaBbgMZ0lyMSuCrb16leeEBBINUN3smBZLDebyg%3d%3d 1/3 8/16/2018 Sections from the Code Florida Building Code Online FL22211 R1 Equiv PERNo2491 RevO 415- 1207 3068TelstarPro ss.pdf '�' I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity 0 Yes 0 No U N/A FL22211 R1 COC Affirmation FL22211 417-1011 ss.pdf Product Approval Method Method 1 Option D Date Submitted 02/27/2018 Date Validated 02/27/2018 Date Pending FBC Approval Date Approved 03/03/2018 Summary of Products FL # Model, Number or Name Description 22211.1 Series 3068 Telstar Pro Out -Swing Series 3068 Telstar Pro Out -Swing Door Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL22211 RI II 101209D RevA TelstarPro ss.pdf Approved for use outside HVHZ: Yes Verified By: Robert J. Amoruso, PE FL PE No. 49752 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +70.18/-70.18 Evaluation Reports Other: This product formally approved under FL17520. FL22211 R1 AE PERNo2491 RevO 415- 1207 3068TelstarPro ss.pdf Created by Independent Third Party: Yes 22211.2 Tioga Doorway System 08-01018 / Tioga Doorway System 08-01018 / TDS-D-KD-WS / Double TDS-D-KD-WS / Double Leaf Side- Leaf Side -Hinged Door Hinged Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL22211 R1 II 08-01018 RevB Tioga TDS-D-KD-WS SS.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Approved for use outside HVHZ: Yes Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +50/-50 Evaluation Reports Other: This product formally approved under FL13889. FL22211 R1 AE PERNo2490 RevO 415- _ 1207 TiogaDoorwaySystem ss.pdf Created by Independent Third Party: Yes 22211.3 Tioga Doorway System 08-01019 / Tioga Doorway System 08-01019 / TDS-D-PA-WS / Double - TDS-D-PA-WS / Double Leaf Side- Leaf Side -Hinged Door Hinged Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL22211 R3 II 08-01019 RevB Tioga TDS-D-PA-WS ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Approved for use outside HVHZ: Yes Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +50/-50 Evaluation Reports Other: This product formally approved under FL13889. FL22211 R1 AE PERNo2490 RevO 415- 1207 TiogaDoorwaySystem ss.pdf Created by Independent Third Party: Yes 22211.4 Tioga Doorway System 08-01020 / Tioga Doorway System 08-01020 / TDS-S-KD-WS / Single TDS-S-KD-WS / Single Leaf Side- Leaf Side -Hinged Door Hinged Door Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: This product formally approved under FL13889. Installation Instructions FL22211 R1 II 08-01020 RevB Tioga TDS-S-KD-WS ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL22211 R1 AE PERNo2490 RevO 415- 1207 TiogaDoorwaySystem ss.pdf Created by Independent Third Party: Yes Tioga Doorway System 08-01021 / TDS-S-PA-WS / Single Leaf Side -Hinged Door Hinged Door I I https://www.floridabui[ding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquY`PIHVa8bgMZOIyMSuCrb161eeEBBINUN3smBZLDebyg%3d%3d . 2/3 8/1612018 Florida Building Code Online Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Installation Instructions FL22211 R1 II 08-01021 RevB Tioga TDS-S-PA-WS ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +50/-50 Evaluation Reports Other: This product formally approved under FL13889. FL22211 R1 AE PERNo2490 RevO 415- 1207 TiogaDoorwaySystem ss.pdf Created by Independent Third Party: Yes 22211.6 Tioga Doorway System 08-01999 / Tioga Doorway System 08-01999 / TDS-S-KD-WS / Single TDS-S-KD-WS / Single Leaf Side- Leaf Side -Hinged Door Hinged Door Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Installation Instructions FL22211 R1 II 08-01999 RevB Tioga TDS-S-KD-WS ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +70/-70 Evaluation Reports Other: This product formally approved under FL13889. FL22211 R1 AE PERNo2490 RevO 415- 1207 TiogaDoorwaySystem ss.pdf Created by Independent Third Party: Yes 22211.7 Tioga Doorway System 08-02000 / Tioga Doorway System 08-02000 / TDS-S-PA-WS / Single Leaf TDS-S-PA-WS / Single Leaf Side- Side -Hinged Door Hinged Door' Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL22211 RI II 08-02000 RevB Tioga TDS-S-PA-WS ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Approved for use outside HVHZ: Yes Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +70/-70 Evaluation Reports Other: This product formally approved under FL13889. FL22211 R1 AE PERNo2490 RevO 415- 1207 TiogaDoorwaySystem ss.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® eClreik M Credit= • Safe sectlritynll: rxi cs• r_app_dtl.aspx?param=wGEVXQwtDquYPIHVa8bgMZ0lyMSuCrb16IeeEBBINUN3smBZLDebyg%3d%3d 3/3 43 1/2' MAX. OVERALL WIDTH 40' MAX. FRAME WIDTH 35 3/4' MAX. �JI PANEL WIDTH — I AM B CLIP MAX ��l II ASSSEBLJAMB JAMB ASSTO DETAIL HEIGHT 86' MIN 90' MAX 83 1/8' OVERALL MAX HEIGHT PANEL HEIGHT 38' MIN TO 42 1/2' MAX 2' 12' MAX SEE SUB JAMB MAX. I O.C. TYP CLIP TO FLOOR DETAIL SHEET 2 TIOGA DOORWAY SYSTEM TDS—S—PA—WS EXTERIOR VIEW DESIGN PRESSURE RATING IMPACT RATING ±50PSF LARGE AND SMALL THIS SYSTEM WAS NOT TESTED FOR WATER INFILTRATION AND IS TO BE INSTALLED ONLY MISSILE IMPACT WHERE THE WATER REQUIREMENT IS NOT NEEDED TELL Spectrul uum C' NOTES: 1 ) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ. 2) STEEL FRAMING AND CONCRETE OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND CONCRETE OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3) BUILDING GIRT AND OPTIONAL INTERMEDIATE BUILDING GIRT TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. BUILDING GIRT AND OPTIONAL INTERMEDIATE GIRT ARE THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 4) ALLOWABLE STRESS INCREASE OF 113 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 5) FRAME MATERIAL: FORMED 16GA. (.053" MIN.) GALVANNEALED STEEL. 6) DOOR PANEL MATERIAL: FORMED 20GA. (.036" MIN.) GALVANNEALED STEEL. 7) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 8) EACH PANEL IS FITTED WITH THREE HINGES LOCATED AT 6" MINIMUM UPTO 10" MAXIMUM FROM EACH END WITH ONE AT PANEL MIDSPAN. HARDWARE SCHEDULE A. ML 1300 MORTISE LOCK BY TELL MANUFACTURING, INC. B. RIM PANIC DEVICE 9500 SERIES BY TELL MANUFACTURING, INC. C. CYLINDRICAL LOCK LC1200 SERIES BY TELL MANUFACTURING, INC. D. STEEL HINGES H4545 BY TELL MANUFACTURING, INC, E. ALUMINUM THRESHOLD 1/2' HIGH BY HOUSTON NDN—FERROUS ITEMS A, B AND C ARE INTERCHANGEABLE TABLE OF CONTENTS SHEET NO. DESCRIPTI❑N 1 ELEVATION, ANCHORING LAYOUT AND NOTES 2 DETAILS AND NOTES 3 BILL OF MATERIALS AND CROSS SECTION 4 CROSS SECTION 5 — 6 INSTALLATION DETAILS 7 — 8 COMPONENTS Robert J. Amoruso, P.E. Florida P.E. No. 49752 TJH 07/06/10 APPROVED DATE MF� IF- Ipi —W IS 11[ FILMY 6 SG6itl11 D s ITM " MTmTW RJA 03/20/17 74Da; MID L9 " 1, IRApt SCC9.TS RffYRTlYS THIRD ANGLE PROJECTION RILE �1'' Harare& M rlS Co rd S2Ki&EDisc�rD10M- PTO PRODUCT DESIGN GROUP, LLC Home)mp10Y0fI1@!11 uwrtlml:ta xetw. CM. . RASlm v�1a SLciM pvIDy pjID wn[N PO BOX 5207751LONGWOD,FLORIDA 32752 FBPE CA.25935 Phone: 321.690.17881 Email: inlo@ptc-corp.com TELL DOORS & WINDOWS, LLC, 2505 WEST 11TH STREET, HOUSTON, TEXAS 77008 TIOGA DOORWAY SYSTEM TDS—S—PA—WS OS STEEL SINGLE DOOR — IMPACT ELEVATION, ANCHORING LAYOUT AND NOTES v ND 08-01021 STATE FINAL EB ITS t I OF 8 STRIKE SUB JAM: EXTERIOF o-\ EXTERIOR SUB JAMB CLIP TO FLOOR DETAIL INTERIOR (2) PER LOCATION IP IS ATTACHED SUB JAMB AND AME JAMB WITH ITEMS #24 'ERI OR I JAMB CLIP ALLATION TORS STRIKE CLIP IS SPOT WELDED TO JAMB CORNER CONSTRUCTION DETAIL SUB J* CL: EXTERIOF SUB JAMB CLIP TO SUB JAMB ASSEMBLY DETAIL TELL MFG Spectrum I Hardware & Home Impraveen� Improvement NOTES: 1) FOR ANCHORING SUB JAMB CLIP TO 16GA. (.060" MIN.) STEEL FRAMING USE 5/16"-18 BOLT WITH 5/16"-18 NUT AND.5/16" WASHER. BOLT TO BE OF SUFFICIENT LENGTH TO ACHIEVE 3-THREADS MINIMUM BEYOND NUT. LOCATE ANCHORS AS SHOWN IN ELEVATION AND INSTALLATION DETAILS. 2) FOR ANCHORING SUB JAMB CLIP INTO CONCRETE AT FLOOR USE: - 5/16" MINIMUM 90' L-BOLT SET IN CONCRETE WITH 5/16" NUT AND WASHER. BOLT TO BE OF SUFFICIENT LENGTH TO ACHIEVE 6" MINIMUM EMBEDMENT INTO CONCRETE AND 3-THREADS MINIMUM BEYOND NUT AND WASHER WITH 2 3/4" MINIMUM EDGE DISTANCE. 90" L-BOLT TO BE MINIMUM A36 STEEL. - 3/8" HILTI KWIK BOLT 3 OF SUFFICIENT LENGTH TO ACHIEVE 2 1/2" MINIMUM -EMBEDMENT INTO CONCRETE WITH 4 1/2" MINIMUM EDGE DISTANCE - 318" WEDGE BOLT OF SUFFICIENT LENGTH TO ACHIEVE 2" MINIMUM EMBEDMENT INTO CONCRETE WITH 4 1/2" MINIMUM EDGE DISTANCE. - 5/16" ITW TAPCON OF SUFFICIENT LENGTH TO ACHIEVE 1 3/4" MINIMUM EMBEDMENT INTO CONCRETE WITH 3 3/16" MINIMUM EDGE DISTANCE. LOCATE ALL ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 3) FOR ANCHORING THRESHOLD INTO CONCRETE USE 3/16" ITW TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 114" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 4) FOR ANCHORING SUB JAMB CLIP TO WOOD USE 5/16" LAG SCREW WITH MINIMUM EMBEDMENT OF 1-3/4", MINIMUM EDGE DISTANCE OF 1-1/4" AND MINIMUM SPACING OF (2) PER 1-1/4". LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. LOCATION 5) WASHERS SHALL BE USED WHEN ANCHORS ARE INSTALLED IN OVERSIZE HOLES (CLIP HOLE DIAMETER 1/16" GREATER DIAMETER THAN ANCHOR DIAMETER). 6) MINIMUM 2 ANCHORS PER SUB JAMB CLIP FOR ATTACHMENT TO SUPPORTING SUBSTRATE 7) ALL FASTENERS TO BE CORROSION RESISTANT. PIS ATTACHED 8) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR SUB JAMB AND MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN ME JAMB WITH ITEMS tt24 SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: ITA. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42 (NON-HVHZ) AND G=0.55 (HVHZ) B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. C. STEEL FRAMING: 16GA. (.060" MIN.) Robert J. Amoroso, P.E. Florida P.E. No.49752 TERIDR JAMB PTC PRODUCT DESIGN GROUP, LLC PO SOX 520775 1 LONGWOOD, FLORIDA 32752 FBPE C.A. NO. 25935 Phone: 321.690.17881 Email: Info@pica p.com ` TELL DOORS & WINDOWS, LLC. DATE 2505 WEST 11TH STREET, HOUSTON, TEXAS 77008 TITLE TIOGA DOORWAY SYSTEM TDS-S-PA-WS DATE ❑S STEEL SINGLE DOOR - IMPACT TJH 7/06/10 DETAILS AND NOTES DATE B o 08-01021 RJA 03/20/17 ANGLE PROJECTION RELEASE STATE FINAL EB NTS 2 OF s III t PARTS LIST PART NUMBER DESCRIPTION MANUFACTURER MATERIAL T-10.3.1 TIDGA PA HEAD JAMB 16GA. TELL MANUFACT. GALVANNEALED STEEL T-10,2,1 TIOGA PA HINGE JAMB 16GA, TELL MANUFACT. GALVANNEALED STEEL T-1,7 THESHOLD, 1/2' HIGH HOUSTON NON-FER. ALUMINUM 6063-T5 T-1,2,2 FRAME HINGE REINFORCEMENT 10GA, DAYTON INDUSTRIES GALVANNEALED STEEL T-1,1,1 TIOGA BOTTOM DOOR SKIN 20GA, TELL MANUFACT, GALVANNEALED STEEL T-1,1,2 TIDGA TOP DOOR SKIN 20GA. TELL MANUFACT. GALVANNEALED STEEL T-113 TOP CAP DOOR CHANNEL 20GA, TELL MANUFACT, GALVANNEALED STEEL T-1,1,4 TELL _MANUFACT. GALVANNEALED STEEL T-1,1,5 BOTTOM DOOR CHANNEL 16GA. TELL MANUFACT. GALVANNEALED STEEL T-1,1,6 DOOR HINGE REINFORCEMENT IOGA, DAYTON INDUSTRIES GALVANNEALED STEEL T-117 DOOR FOAM CORE 1 LB/FT DENSITY POLYSTYRENE T-1,1,8 DOOR CLOSER REINFORCEMENT 1213A. TELL MANUFACT. GALVANNEALED STEEL T-1,1,10 MORTISE LOCK REINFORCEMENT 1413A. TELL MANUFACT, GALVANNEALED STEEL T-10.4.1 TIDGA PA STRIKE JAMB 166A. TELL MANUFACT. GALVANNEALED STEEL T-10,4,3 PA STRIKE JAMB CLIP 12GA. TELL MANUFACT. GALVANNEALED STEEL T-10,2,3 PA HINGE JAMB CLIP 12GA. TELL MANUFACT. GALVANNEALED STEEL T-1,2,4 FRAME WEATHERSTRIPPING FOAM T-1,5 HINGES - H4545 SERIES TELL MANUFACT, STEEL T-1,68 MORTISE LOCK ML 1300 TELL MANUFACT. STEEL T-I,6A CYLINDRICAL LOCK LC1200 SERIES YALE SECURITY T-1,8 DOOR SWEEP, DT100101 TELL MANUFACT. ALUMINUM 6063-T5 T-10.9 TIDGA PA SUB JAMB 16GA. TELL MANUFACT. GALVANNEALED STEEL T-10.10 TIOGA PA SUB JAMB CLIP 126A. GALVANNEALED STEEL S1 #12-24 X 1 1/4' HEX HEAD TEK STEEL B1 5/16-I8 X 3/4' HEX CAP SCREW STEEL N1 HEX NUT 5/16" STEEL W1 FLAT WASHER 5/16" STEEL S2 #8-32 X 1/2' PPH SMS STEEL S2 #14 X 1/2' PFH SMS STEEL S3 #10-24 X 1/2' UC PFH SMS STEEL T16C RI- PANIC DEVICE 9500 SERIES TELL MANUFACT. T-1.1,9 CYLINDRICAL LOCK REINFORCE. 16GA I TELL MANUFACT. I GALVANNEALED STEEL TEES Specttrum MEG Hondvwre & Home Improvement Fv- VERTICAL CROSS SECTION TJH 107/06/10 RJA 103/20/1 THIRD ANGLE PROJECTION Robert J. Amoruso, P.E. Florida P.E. No. 49752 i, Qti 1pMEs quo Digitally signed om�,LcEHSF.a� byRobert J ,,Amoruso 9��•�TA Ei- or .:mow Date: 14:08:46-04'00' r J T a' PTC PRODUCT DESIGN GROUP, LLC PO BOX 520775 1 LONGWOOD, FLORIDA 32752 RIPE C.A. NO. 25935 Phone:321.690.179B I Email: info@pt, c rp.00m TELL DOORS & WINDOWS, LLC, 2505 WEST 11TH STREET, HOUSTON, TEXAS 77008 TIOGA DOORWAY SYSTEM TDS-S-PA-WS ❑S STEEL SINGLE DOOR - IMPACT BILL OF MATERIALS AND CROSS SECTION B I I "D 08-01021 STATE FINAL NTS[SHEET HORIZONTAL CROSS SECTION Robert J. Amoruso, P.E. Florida P.E. No. 49752 i' nmLs Ly Digitally signed ned 1 ` by Robert � 4Q'.• pEM6':�9 1 �```p0i � F •; w't 1'I Sa e,Amoruso O:.`Date: O... ........ ..p 'kr 14:08:57-04'00' PTC PRODUCT DESIGN GROUP. LLC PO BOX 5207751 LONGWOOD. FLORIDA 32752 FBPE CA. NO.25935 Phone: 321.690.17881 Emall: into@plocorp.wm TELL DOORS & WINDOWS, LLC, 2505 WEST 11TH STREET, HOUSTON, TEXAS 7700E TIOGA DOORWAY SYSTEM TDS-S-PA-WS ❑S STEEL SINGLE DOOR - IMPACT ENGINEER DATE TJH 07/06/10 CROSS SECTION TELL M E Bar Q K�w7� I M " APPROVED RJA DATE 03/20/17 SILL B "° 08-01021 Spectrum I Hardware & B1ilI1aS Home Improvement ,�=D1�"-UM7"� "� M - R�`:'� � . w ° rF� oE0 THIRD ANGLE PROJECTION RELEASE STATE FINAL EB N T S SHEET 4 OF 8 h o � (3) ALONG HEAD SUB JAMB CLIP STRIKE 5/16' BOLT WITH 5/16' NUT AND WASHER. BOLT MUST BE 3-THREADS BEYOND NUT MIN. ENGAGEMENT STRIKE BUILDING GIRT BY OTHERS EX1 ® CONCRETE FLOOR SUB JA B BY OTHERS INTERIOR 5/16' BOLT WITH 5/16' NUT AND WASHER. BOLT MUST BE 3-THREADS BEYOND NUT MIN. ENGAGEMENT SUB JAMB CLIP BUILDING GIRT BY OTHERS STRIKE JAMB SUB T E L L M F- G JAMB VERTICAL CROSS SECTION Spectrum I Hardware & SUB JAMB TO GIRT Brands Home Improvement VERTICAL CROSS SECTION SUB JAMB CLIP TO CONCRETE FLOOR INSTALLATION Its immb RIOR (4)PER CLIP JAMB 16' MINIMUM 90' L-BOLT SET IN CONCRETE rH 5/16' NUT AND WASHER. BOLT TO BE SET IN CONCRETE MIN. AND HAVE 3-THREADS MIN. rOND NUT MIN. ENGAGEMENT AND 2 3/4' MIN. 3E DISTANCE OR 3HILTI KWIK BOLT 3 WITH 2 1/2' MIN. EMBEDMENT INTO CONCRETE AND 4 1/2' MIN. EDGE DIST. Robert J. Amoruso, P.E. Florida P.E. No. 49752 ...............' Digitally signed `•.eW�:.�GEti8F �9G:� by Robert Amoruso yDate:_ EE O z ...... loam c• 2017.04.07 'WONAL,E„.•• " 14:09:08-04'00' PTC PRODUCT DESIGN GROUP, LLC PO BOX 5207751 LONGWOOD, FLORIDA 32752 FBPE CA. NO.25935 Phone:321.690.17881 Email: into@ptc-mrp.com AFTER DATE TELL DOORS & WINDOWS, LLC, 2505 WEST 11TH STREET, HOUSTON, TEXAS 77008 IECKED DATE TITLE TIDGA DOORWAY SYSTEM TDS—S—PA—WS IGINEER DATE ❑S STEEL SINGLE DOOR — IMPACT TJH 7/06/10 INSTALLATION DETAILS PROVED DATE Dwu NG 0 8 - 010 21 RJA 03/20/17 THIRD ANGLE PROJECTION ELEASE STATE FINAL IEVB NTS SHEET 5 ❑F 8 STRIKE JF EXTERI CONCRETE FL❑❑ BY OTHERS VERTICAL CROSS SECTION SUB JAMB CLIP TO CONCRETE FLOOR INSTALLTION IOR JAMB (4)PER CLIP JAMB CLIP 716' IlW TAPCON WITH 1 3/4' MIN. 4BEDMENT INTO CONCRETE AND 3/16' MIN. EDGE DIST. OR �8' WEDGE BOLT ANCHOR WITH 2' MIN. 4BEDMENT INTO CONCRETE AND 1/2' MINIMUM EDGE DISTANCE TELL MEG Spectrum I Hardware & Brands Home Improvement EXTERIOR 0 U O V INTERIOR O O 0000 O O / TAPCONTW CONCRETE FLOOR BY OTHERS A 9 Q ' 1 3/4' MIN. 4 e: EMBEDMENT a � . 2 5/8' MIN. EDGE DIST. VERTICAL CROSS SECTION SILL TO CONCRETE FLOOR INSTALLATION Robert J. Amoruso, P.E. Florida P.E. No. 49752 yraFs A4 Digitally signed 4$ by RObertJ -"=Amoruso Date: - 1V•. STA E 04- F ;W ' FS`<,oa�p."••vr' 2017:04.07 nl„JJO��NA"E;a�� 14:09:18-04!00' d .s'YRi PTO PRODUCT DESIGN GROUP, LLC PO BOX 520775 i LONGWOOD. FLORIDA 32752 FBPE C.A. NO.25935 Phone: 321.690.17881 Email: info@ptc-corp.com DRAFTER DATE TELL DOORS & WINDOWS, LLC. 2505 WEST 11TH STREET, HOUSTON, TEXAS 77008 CHECKED DATE TITLE TIOGA DOORWAY SYSTEM TDS—S—PA—WS OS STEEL SINGLE DOOR — IMPACT ENGINEER DATE TJH07/06/10 INSTALLATION DETAILS T 6mTm APPROVED DATE B NO 08-01021 1TEi T E S C@i8E11ft RJA 03/20/17 �Tn ,Tr THIRD ANGLE PROJECTION RELEASE STATE FINAL EB � VEIiI[M SCALE N T S SHEET 6 OF 8 1/i O TIOGA PA HINGE JAMB 14 TIOGA PA STRIKE JAMB 166A, GALVANNEALED STEEL .053' MIN. THICK �vm 8 n 1/2' 5 3/4' �{ THRESHOLD 1/2' HIGH ALUMINUM 6063—T5 ,105' THICK O TIOGA BOTTOM DOOR SKIN 20GA GALVANNEALED STEEL ,036' MIN. THICK LEFT END SHOWN, RIGHT END IS SIMILAR 5/16' O TIOGA TOP DOOR SKIN 20GA STEEL .036' MIN. THICK LEFT END SHOWN, RIGHT END IS SIMILAR 1 37/64' 23/32' O TOP CAP DOOR CHANNELCHANNEL 20GA GALVANNEALED STEEL .036' MIN. THICK 1 43/64' 23/32' Og TOP DOOR CHANNEL 16GA GALVANNEALED STEEL ,053' MIN, THICK 1 43/64' 23/32' O BOTTOM DOOR CHANNEL 16GA GALVANNEALED STEEL .053' MIN, THICK TELL MFG Spectrum i I HHomee provement I 7/32' 7/8' 1 59/64' 21 DOOR SWEEP ALUMINUM 6063—T5.042' MIN, THICK EPDM 17 3/4' (REF) 9/16'(REF) FRAME WEATHERSTRIPPING FOAM Robert J. Amoruso, P.E. Florida P.E. No. 49752 if Digitally J E"GENy'jpMES•• signed by Q'••:�q' RobertJ Bg �B162 q 0, Amoruso p•., FiA E OF WWI F:2, Dater;---. '''.�SyyONALEN�C� 2017.04.07 7 14:09:32-04'00' PTC PRODUCT DESIGN GROUP, LLC PO BOX 520775 1 LONGWOOD, FLORIDA 32752 FBPE CA. NO.25935 Phone: 321.690.17881 Email: info@plctmp.com TELL DOORS & WINDOWS, LLC. ECKEn DATE 2505 WEST 11TH STREET, HOUSTON, TEXAS 77008 TITLE TIOGA DOORWAY SYSTEM TDS—S—PA—WS GINEER DATE ❑S STEEL SINGLE DOOR — IMPACT TJH 7/06/10 COMPONENTS PROVED DATES1Z V RJA 03/20/17 B NO 0 8 - 010 81 THIRD ANGLE PROJECTION RELEASE STATE EV SCALE NTS FINAL 0 SHEET 7 8 2 ---------- 00 0 o 5'� � �1 3/4' 8 3/64' o 0 4 1/4' 0 0 0 o 0 5 3/4'� 23 TIOGA PA SUB JAMB CLIIP 12GA. GALVANNEALED STEEL ,108' MIN. THICK 5 3/4' O TIOGA PA HEAD JAMB 166A. GALVANNEALED STEEL .053' MIN. THICK 9/32' t 00 000 0 0 O 00 10' 0 0 0 ODO Io 0 1 1/4'� 10 DOOR HINGE REINFORCEMENT TOGA. GALVANNEALED STEEL .138'MIN. THICK 1 15/64'�� 1' 1. O o 0 0 5 9/16' O 5 1/16' 0 0 ® o 15 PA STRIKE JAMB CLIP 16 PA HINGE JAMB CLIP 12GA. GALVANNEALED STEEL .108' MIN. THICK r-� 9/32' --w- 00 000 0 O 0 10' 0 0 000 IO OI �1 1/4' O FRAME HINGE REINFORCEMENT 10GA. GALANNEALED STEEL .138' MIN. THICK 6' TO 12° --�I 1 3/4' Robert J. Amo"so, P.E. TIOGA PA SUB JAMB Florida P.E. No. 49752 16GA, GALVANNEALED C Digitally signed STEEL .053' MIN. THICK 9 Y 9 ;oW?��caNSE °Bs., by Robert) �Amoruso Date: F9.<o p,o^�?,.•• 2017:04'.07 14:09:43-04'00' PTC PRODUCT DESIGN GROUP. LLC PO SOX 5207751 LONGWOOD. FLORIDA 32752 FEPE CA. NO.25935 Phone: 321.690.17881 Email Info@ptc-np.com TELL DOORS & WINDOWS, LLC. 2505 WEST I1TH STREET, HOUSTON, TEXAS 77008 TIOGA DOORWAY SYSTEM TDS—S—PA—WS DATE STEEL SINGLE DOOR ❑S - IMPACT TJH 07/06/10 COMPONENTS TELL I" I V APPROVED AT SIZ TKIS OQ" IS TK mm" or SKCT" B "° 0 8 - 010 21 m1Piiodsv ®.m.61°a'�CDFMDrt RJA 03/20/17 Spectrum I p" `�"�'"" V Hardware & MM s '�E? MS THIRD ANGLE PROJECTION RELEASE STATE Brands���EEO FINAL B SuAL Horne Improvement �, �� ,� � NTS s"T8OF8 _ • r