HomeMy WebLinkAboutBLOWER DOOR TEST FORMQ Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method RECEIVED DEC 2 71018 Permitting aePartent St- Lucie CoonttY e• DECEMBER, 19,2018 Permit #: 1802-0039 tractor: S&D CONTRACTING Address: 7003 S INDIAN RIVER DR, FORT PIERCE, FL 34982 struction: ( ) New Construction — Complete ( ) Existing — After Addition ise Infiltration Test Results SLC Climate Zone 2 A (50) = 1558.8 Test Date: lam"/ / ume = 18351 (50) = CFM (50) x 60 / Volume = 5.1 Mechanical Ventilation required less than 3 ACH ng results must be & ACH (50) or less (x ) Pass ( ) Fail Energy building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a rer door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be, conducted by either individuals as defined in ion 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (1) or an •oved third party. A written report of the results of the test shall be signed by the party conducting the test and Tided to the code official. Testing shall be performed at any time after creation of all penetrations of the building ma/ envelope. , Residential ere the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a ;sure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. pany Name ENERGY DESIGN Address: 1470 N CONGRESS AVE, WPB 33409 I " reby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation re uirements in accordance with Section R402.4.1.2 Climate Zone 2. re: Richard — - _�.. �- - - j Z! Lfv �?,. 1 g Name: RICHARD WALLEN Li�;ense/Certification #: 2019-04-19 RETROTEC OFCR�c�1�Fo pen7vtt' �'TO'® St. 4u s Qoport e C007 111Qnt tk ie County Building Dept/ Permitting Virginia Ave. Pierce, FL 34982 TOWhom it may concern, K.0 Energy/ Design, LLC 1470 N. Congress Ave #106A West Palm Beach, FL 33409 info@koenergyrdesign.com 561327-7272 Main www.KOEnergvDesign.com SQA IVL 'D St. tu By NO iptc 12/26/2018 In Jresponse to your request for an original signature on the Blower Door Test Form Permit # 1802-0039 Project Address: 7003 S Indian River Dr, Ft. Pierce, FL 34982 accept the attached original signature on the form provided by the building and code regulation pectfully, z &W Co1rsultant — Field & Data Analyst KC� Energy Design 561.327.7272 ENERGY CALCS*HEAT LOADS*AC DRAWINGS*COMMERCIAL*RESIDENTIAL* DUCT LEAKAGE AND INFILTRATION BLOWER DOOR TESTING *MANDATORY BLOWER DOOR INFILTRATION TESTNOW REQUIRED ON � RESIDENTIAL JOBS permitted after July 1, 2017 as per FBC R402.4.1.2*