BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
RECEIVED
DEC 2 71018
Permitting aePartent
St- Lucie CoonttY
e• DECEMBER, 19,2018 Permit #: 1802-0039
tractor: S&D CONTRACTING
Address: 7003 S INDIAN RIVER DR, FORT PIERCE, FL 34982
struction: ( ) New Construction — Complete ( ) Existing — After Addition
ise Infiltration Test Results SLC Climate Zone 2
A (50) = 1558.8 Test Date: lam"/ /
ume = 18351
(50) = CFM (50) x 60 / Volume = 5.1 Mechanical Ventilation required less than 3 ACH
ng results must be & ACH (50) or less (x ) Pass ( ) Fail
Energy
building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
rer door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be, conducted by either individuals as defined in
ion 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (1) or an
•oved third party. A written report of the results of the test shall be signed by the party conducting the test and
Tided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
ma/ envelope.
, Residential
ere the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
;sure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
pany Name
ENERGY DESIGN
Address: 1470 N CONGRESS AVE, WPB 33409
I " reby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
re uirements in accordance with Section R402.4.1.2 Climate Zone 2.
re: Richard — - _�.. �- - - j Z! Lfv �?,. 1 g
Name: RICHARD WALLEN
Li�;ense/Certification #: 2019-04-19 RETROTEC
OFCR�c�1�Fo
pen7vtt' �'TO'®
St. 4u s Qoport
e C007 111Qnt
tk
ie County Building Dept/ Permitting
Virginia Ave.
Pierce, FL 34982
TOWhom it may concern,
K.0 Energy/ Design, LLC
1470 N. Congress Ave #106A
West Palm Beach, FL 33409
info@koenergyrdesign.com
561327-7272 Main
www.KOEnergvDesign.com
SQA IVL 'D
St. tu By
NO iptc 12/26/2018
In Jresponse to your request for an original signature on the Blower Door Test Form
Permit # 1802-0039
Project Address: 7003 S Indian River Dr, Ft. Pierce, FL 34982
accept the attached original signature on the form provided by the building and code regulation
pectfully,
z &W
Co1rsultant — Field & Data Analyst
KC� Energy Design
561.327.7272
ENERGY CALCS*HEAT LOADS*AC DRAWINGS*COMMERCIAL*RESIDENTIAL* DUCT LEAKAGE AND INFILTRATION BLOWER DOOR TESTING
*MANDATORY BLOWER DOOR INFILTRATION TESTNOW REQUIRED ON � RESIDENTIAL JOBS permitted after July 1, 2017 as per FBC R402.4.1.2*