Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCERECEIVED t � ry Planning &Development Services Department Building & Code Regulations Division 12018 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 p-,,owng Dapartment County Certification for Design Load Compliance /� Project Name:! ✓ �� I v �% ��C��(Y �� �-�i� ��/{� t .�'�°`� Project Address: 1 15-1 B � IV UJ 5�UF "I � (�I � � �f-�.1 1 l�1�Y 03 Permit #: I t � �l Occupancy Type: Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) scANNED o Residential Addition By o Any accessory structure requiring a building permit Loo COUV (N o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1.. DESIGN CODE: Florida Z O 17 Code Fifth Edition with 20 1 -7 Supplements using ASCE 7-10 2. Structure Designed as (check one): V Enclosed Partially Enclosed Open 3. Risk Category: _I II V"III IV Exposure Category: "�B C D 4. Design Wind Velocity , % 0 mph ✓ASD LRFD End Zone Width: 1 0 ( ft 5. Mean Roof Height i 2 ft Roof Pitch: 5_:12 Parapet: _t��ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft�2@ 15'MRH, clearly label on all plan openings): Zone 1: � Zone 2: Zone 3: � Zone 4: —3-7 Zone 5: `- � 2 Garage: 7. Design Loads: Floor: 40 PSF Roof/Dead: PSF Roof/Live:Balcony: AJ�PSF Dock: PSF Deck: WAPSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? V Yes Not Applicable Explain Why Not: v 10. Design Soil Bearing Pressure: N �a PSF Soil Test Reports Submitted?p P'Yes ex, �) 0� DESIGN PROFESSIONAL CERTIFICATION STATEMENT: -F0 oc'" I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie Cogaty sq-_,ggify that structural elements depicted on these plans provide adequate resistance to the design T: . Print Name Cert # & Co. Cert Auth. e FO(gip I K4-) c�l�t,Sf�nat re,P e, and ° } IFL Company Name & Address q (©�