HomeMy WebLinkAboutPOOL HEAT PUMPJ Z_/ Li L-11)- Li
aC�L.14 map �
anly
by-LOUTACtw
HEAT PUMP
n y
, � 4
- *rya+s •r. �w �• •�rY .. - "-�C—Y }- �is
• • r - r r. N, 1lwFY�aiL�
t �` p a
1. �. .�' �.; ' �� �•�J >'�. - �' L ' rJ ! � � �- -
V-;, __ , •. -ice , _ ` - : _
sms-
_ - v
-: H e♦a t-s, = r�C�f��l�l�--
rc
i'
J9 3000T7A
HEAT PUMP.
E prgyefficient pool and
spa heating
The JE3000T is the most advanced heat pump
Line �vailable. By absorbing free heat from the
air 'nd tran- sferring'it to the.water,.JE3000T
heal pumps -make the heating process efficient,
eco';ogical, and most of all, cost effective. And,
with! the JE3000TR reversing models; you can even
coo :your. pool*during the hot summer months
wit l the innovative Ghill mode.-
» 0 tional chiller/hot gas defrost.
C. ill your pool during- hot summer nights.
» U tra Efficient
F'aturing a premium titanium heat exchanger,
JI Heat Pumps provide superior hydraulic
fl w for maximum energy savings.
o S perior.Gontrol _
D al thermostats (pool/spat.
F atures advanced digital control to enable
s Ilf diagnostics, multilingual capability, and an auto -heat
f ature, when used in conjunction with Aqualink® control
s.stems, to maintain your pooLs.temperature automatically
a d efficiently.24 hours per day. .
J1 Series'Heat Pumps are iAquaLink". compatible so -you
c n. adjust the temperature of your pool or spa from your
sMartphone, tablet, or otherweb-enabled device. (purchased
>> W rsa Plumb° Ready:
All JE Heat Pumps are Versa Plumb ready, allowing you to achieve
5 % more hydraulic efficiency for maximum energy savings.
V" rsat(le
so availab(e:.JE1500T (72,000 BTU), JE2000T.1103,006 BTU),.
a d JE2500.T (113,000 BTU). 3 phase models also available.
Ovironmentally friendly (410A refrigerant)
Zodiac Pool Systems,.lnc. .
2620 Commerce Way, Vista, CA 92081 .
1.800.822.7933 1 www.ZodiacPoo[Systems.com
DIMENSIONS q1 E
3
JE3000T
JE3000TR
.JE3000T3.
JE3000TR3"
Output* (BTUs)
137;000
137,000
137,000 .
137,000
Input* (kW) _
6.37 .
. 6.37.".
6.37
6.37
COP*
6.3 -
6.3 -
6.3
6.3
Output, SRC (BTUs)
127;000
127,000
127,000
127;000
COP, SRC
6.0 -
5.9
6
5.9
Output; Low Ambient 86,000
86,000
86,000 .
86,000
C.O.P. Low Ambient
4.2
4
4.2
4
Voltage
230V/60H.z
230V/60Hz
208/230V/60Hz/3 208/230V/601-10.
Minimum Circuit -
.Ampacity .
41.81
41.81 .
33.00
33.00
Max Over Current
Protection**
60
60
50
. 50
LRA.
185
185
164
164
RL-A
32:05
32.05'.
25.0'0
25.00
Compressor :
Scroll
Scroll
Scroll
Scroll
Heat Exchanger.
Titanium
Titanium
Titanium
Titanium -
High Flow
High Flow
. High.Flow
High Flow
Optimal Water.Flow
57
57
67
57
(GPH)
Minimum Water
20
20
20
20
Flow (GPH)
Maximum Water
70
70
70
70
Ffow (GPH)
Weight (lbs.)
228
230 .
228.'
230
* Outside the scope of AHRI Standard 1160 (I-P)
** AHRI Standard 1.160 0-PI
SRC: Standard:Rating Conditions