Product Evaluation Report
GULF COAST SUPPLY & MANUFACTURING, LLC
26 Ga. 5V Crimp Roof Panel over 15132" Plywood
Florida Product Approval #11651.13 R2
Florida Building Code 2014
Per Rule 61 G20-3
Method: 1 -D
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 61 G20-3.005(1)(d)
NON HVHZ
Product Manufacturer:
Gulf Coast Supply & Manufacturing, LLC.
14429 SW 2nd Place, Suite G30 ®818 s 1 a a,,
Newberry, FL 32669 P�AE..�
No, 755is .=
STATE 01='
;ems► . , O R t D•
,'�8 0888 tq.
0.6�3o�zo�s
RECEIVE®
SEP 0` 12017
PERMITTING
St. Lucie County, FL
SCANNED
BY
Engineer Evaluator:
Dan Kuhn, P.E. #75519
Florida Evaluation ANE ID: 10743
Validator:
Locke Bowden, P.E. #49704
9450 Alysbury Place
Montgomery, AL 36117
Contents:
Evaluation Report Pages 1 - 5
11651.13 R2 • JUNE 15, 2015
Gulf Coast
SUPPLY & MANUFACTURING
Code Compliance: The product described herein has demonstrated compliance with the
Florida Building Code 2014, Sections 1504.3.2.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2014, as relates to Rule 61 G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
• UL 580-06 - Test for Uplift Resistance of Roof Assemblies
• UL 1897-04 - Uplift Test for Roof Covering Systems.
Reference Data:
1. UL 580-94 / 1897-98 Uplift Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 117-0053T-05 & 117-0331 T-08
2. Certificate of Independence
By Dan Kuhn, P.E. (FL# 75519) 0 Kuhn Engineering, LLC
(FBC Organization # ANE ID: 10743)
Test Standard Equivalence:
1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test
standard.
Quality Assurance Entity:
The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61 G20-3.005(3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity.
Minimum Slope Range:
Minimum Slope shall comply with Florida Building Code 2014, including
Section 1507.4.2 and in accordance with Manufacturers recommendations. For
slopes less than 3:12, lap sealant must be used in the panel side laps.
Installation:
Install per Manufacturer's recommended details.
Underlayment:
Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2.
Roof Panel Fire Classification:
Fire classification is not part of this acceptance.
Shear Diaphragm:
Shear Diaphragm values are outside the scope of this report.
11651.13 R2 • JUNE 15, 2015
Gulf CoL'af's'- t
SUPPLY & MANUFACTURING
W5
Compliance Statement:
The product as described in this report has demonstrated compliance with the
Florida Building Code 2014, Sections 1504.3.2.
Product Description:
5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage, through fastened
roof panel with fasteners in the panel flat over minimum 75/m" plywood decking.
Non Structural application.
Panel Material/Standards:
Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to
Florida Building Code 2014 Section 1507.4.3.
Paint Finish Optional
Yield Strength: 80.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2014, Section 1507.4.3.
Panel Dimension(s):
Thickness: 0.018" Minimum
Width: 24" Coverage
Rib Height: 3A" Major Rib
Panel Fastener:
#9-15x1.5" with sealing washing in the flat of the panel or approved equal,
'/a" minimum penetration through plywood.
Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4
Substrate Description:
Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C.
Design of plywood and plywood supports are outside the scope of this evaluation.
Must be designed in accordance w/ Florida Building Code 2014.
Design Uplift Pressures:
11651.13 R2 • JUNE 15, 2015
Table "A"
Ma imum To "a 11,
ileni94
1 1.0 ps
Fastener Pattern
12"-12"
9.5"-2"-9.5"
Fastener Pane n Spaei
16 �
16
Design Pressure includes a Safety Factor = 2.0.
Gul-iCol t
SUPPLY & MANUFACTURING
WW
Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must
at a minimum meet those listed for the applicable wind zone. For all roofs outside
the parameters listed on the load table, design wind loads shall be determined
for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10
using allowable stress design. The maximum fastener spacing listed herein shall
not be exceeded_ This evaluation report is not applicable in High Velocity
Hurricane Zone. Refer to current RIOA or HVHZ evaluation report for use of this
product in High Velocity Hurricane Zone.
11651.13 R2 a TUNE 15. 2015
EN INEER LOAD TABLE: 26 Ga. 5VCrimp Roof Panel over 15/32" Plywood
Bail'
dns avfi 9 a R<x� n eig ZO' o0
5 o A 12' - 12 '/1 ' Gable car ip ocf; Wind Speeds 12C3-
� 8"
pl , -,� ,our es Cate�oty Il, 1=n�losecl B ilcing,
based r n F)� icEa B i d' Co>�3e Zii14.
130 140 150 160 170
180
120
IND
FASTENER
SUBSTRATE
S
ED
(MIN. V4"
Penetration)
(MIN.15/32")
ON CENTER
ON CENTER
'ON CENTER
ON CENTER
ON CENTER
ON CENTER
ON CENTER
SPACING
SPACING
SPACING
SPACING
SPACING
SPACING
SPACING
Z a
NE 1
#9-1F5x1.5'
Plywood
16" PE 1
16 PE 1
16" TYPE 1
6' TYPE 1
16" 'rYP 7
16` TYPE 1
1,6"'TYPE 1
Z
�E 2
#9-15x9.5"
Plywood
16" TYPE 1
16" TYPE 1
16" TYPE 1
16" TYPE i
16" TYPE 1
16" TYPE 1
16" TYPE 1
Z.=
:NE21=1
$ ood
16 TYPE 9
16" TYP i
16" PE 1
i6" E 1
9&" PE '!
16" iYPE 2
16' P 2
1.)
I4NEL DESCRIPTION: 5V CRIMP, MIN. 26 GA., GRADE 80, 24"COVERAGE.
2.)
NEL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER W/ MIN. 1/4" PENETRATION.,
3.)
MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: -94.25 PSFO 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN, -131.0
PSF
16-° O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING.
4.)
nOOD DECKING: MIN.%" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014.
5.)
OOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS.
6.)
OAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING
CO
2014
ZOT7E 2 RIP ROOF ZONE 3 a
Note: Dimension (a) is defined as 10% of the minimum width of the building or
a 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be
- - - - - - - - - -- -- -
less than either 4% of the minimum width of the building or 3 feet.
RIME
TYPE 1 FASTENER PATTERN
---------
(1) #9-15 X 1-1/2" !HWH w/Sealing Washer
ZONE 1
At Panel Lap—�
—EAVE
ZONE 2 GALE ROOF
-a
--------------------�
TYPE 2 FASTENER PATTERN
Ri°GE ;
(1) #9-15 x 1-1/2" HWH W/Sealing Washer
------------------------4
I
a
ZONE
I I