HomeMy WebLinkAboutLETTER PERMITS NEEDED FOR WORK COMPLETEDA-
FASIDE VC NNED
- ENGINEERS - 8t L4� BY
Civil and Structural Engineering
April 1, 2019
,andy Dehmer
216 201h Street
'ero Beach, FL 32960
)b Location: 8005 Belmont Ave, Fort Pierce
irisdiction: St. Lucie County
a rce l:1301-604-0123-100/0
ermit Number: LrC-1$090053
1r. Dehmer,
APR 1 2019
Permitting Department
St. Lucie County, FL
i reference to a project at the above -mentioned address, an after the fact permit is needed for work
)mpleted. Specifically, the following was installed without a permit:
1. Electrical connection to new ceiling mounted gang boxes
2. Water heater: 40 gallon, 4500 watt
3. Exterior Swing Door: FPA # 16468-1112 (+/- 60 psf)
4. SH Windows (non Impact) with Shutters: FPA # 12856-116 ( +35 / - 38psf)
5. Garage Door: FPA # 16107-R10 (+38 / -44 psf)
lith the following design consideration, the wind pressures are as follows:
Gable/Hip Roof 7deg < Angle <= 27deg,160MPH, Exposure B, Mean Roof
Height = 25 ft_ a = q ft
Max. Component & Cladding Pressures,'ASD (PSF)
Zone
Effective Area (SQFT)
0 -10
10 -100
100 - 500
>500
-25.3
15.9
-25.3
11.2
-22.9
11.2
-22.9
0
2
15.9
. -44.0
15.9
-44.0
11.2
-32.3
11.2
-32.3
3
15.9
-65.0
15.9
-65.0
11.2
-51.0
11.2
-51.0
4
27.6
-29.9
27.6
-29.9
23.5
-25.8
20.6
-22.9
5
27.6
-37.0
27.6
-37.0
23.5
-28.7
20.6
-22.9
4
27.6
-29.9
27.6
-29.9
23.5
-25.8
20.6
V°
5
27.6
-37.0
27.6
-37.0
23.5
-28.7
20.6
4265 601 Court * Vero Beach, Florida 32967 * (772) 202-8008 *info@seasideengineers.com
www.seasideengineers.com
so
so
The items listed above, along with the construction framing, were installed per code and per
manufacturer's requirements. Please feel free to contact me if you have any questions.
Sincerely,
Edward oske, PE, LEED AP 9 Principal Engineer
Seaside Engineers 1 (772) 202-8008 1 edward@SeasideEngineers.com