Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FIELD WITHDRAWL RESISTANCE TEST RESULTS DECK A
o©Uq TESTING APPLICATION STANDARD (TAS) 105-98 xl�'lf APPENDIX A C FIELD WITHDRAWAL RESISTANCE TEST RESULTS REPORT ��Neo 4875 Park Ridge Blvd., Suite 108 • Boynton Beach, Florida 33426 • (561) 734-3818 (Phone) • sduhon@dreroofconsulting.com SERVING FLORIDA AND BEYOND ENERAL INFORMATION: I Job Name: Foxx Residence Project Number: 18-2164.00 Job Address: 403 N 40th St. Pierce, FL 34947 Contact Individual at job site (if any): l Area Tested: Deck A Date Tested: 9/20/2018 Report Number: 1 ESTING AGENCY/EQUIPMENT INFORMATION: ote: The undersigned acknowledges that all testing has been conducted and results have been reported in compliance with TAS 105 or TAS 105 Appendix A' Testing Agency Name: Duhon's Roof Consulting, LLC - FBPE CA#: 32207, NOA# 18-0801.02 Address: 4875 Park Ridge Blvd., # 108 Boynton Beach, Florida 33426 Telephone: 561-734-3818 Fax: N/A Technician: Erich Velzy Certified By: Hector Vergara, FL P.E. License #25764 Signatur &ADa�tee::� I 1/0j25764/ p STATE OF 0. P ���FS•. OR1 • Test Apparatus (Gen'l Description): Force Measurement System DMD PT1000 h,S 105-11 C /ROOF SYSTEM INFORMATION: Roof Area Height: Roof Area Dimensions: deck height (ft) largest dimension (ft) second largest dimension (ft) total roof area squares perimeter width perimeter area (see RAS 117) Area No. Deck A 11 Roof Submittal (if known): Miami -Dade NOA No. Page No. of ITENER INSTALLATION INFORMATION: Is the fastener a self driller? Yes X No If yes, list the type of tool used for fastener installation: Dewalt 20V Max Speed of Tool: 0-2000/min rpm's {T INFORMATION: Number of Tests Conducted: n = 10 • 10 tests for the first.10, 000 sf + 3 test for each additional 5,000 sf. • Multiply by 125%for lightweight concrete. • See Section 8.f of TAS 105 • Note the location of all tests on `Sketch of Roof, attached hereto LD WITHDRAWAL RESISTANCE TEST RECORDING SHEET No. Deck A Fastener Type: # 14 HD r to deck dimensions referenced on page 2 Fastener Manufacturer: OMG ponent to be secured: Pre -drilled? Insulation X Yes No X Membrane X If yes, Drill bit size: Anchor or Base Sheet Wood blocking Hole Depth: Metal Profiles iection 8.o of TAS 105 to determine number of tests (If drill bit is high tolerance, include range in 1/1000" tolerances) AS 105-11 Page 2 792 ft2 8 sqs 3.00 ' 336 f 2 " dia. SAWLE INITIAL FAILURE LOAD ire NO.: PLAN IDENTIFIER (Ibi7 _j =FIELD„ PERIM -TEWOR CORNERI(circib one)�*::Ar ^ 1 1 390 F P (C) 2 2 443 F P (C) 3 1 3 161 F (P) C 4 4 393 F (P) C l 5 5 465 F P (C) 6 6 370 F (P) C 7 7 340 (F) P C �I 8 8 355 (F) P C 9 9 405 (F) P C 10 10 395 (F) P C TATISTICAL ANALYSIS: Mean Failure Load: F = 371.70 lbf Sample Standard Deviation: SF = 82.94 lbf Minimum -Characteristic Resistance Force F' = 351.12 lbf otes: 1. Use of the results herein to determine the required number of fasteners for insulation attachment or an acceptable anchor or base sheet fastener spacing, as outlined in TAS 117, shall utilize the minimum characteristic resistance force (F'), determined in compliance with Section 9.f TAS 105. No margin of safety shall be applied to field withdrawal resistance test results determined in compliance with TAS 105. 2. A safety factor of 2 to 1 shall be applied to all results of laboratory testing. 3. The following pages shall be completed for each roof area and included with all Field Withdrawal Resistance Test Recording Sheets. Notes: Conclusion: This wood deck passed the TAS 105 Fastener Withdrawal Test as per the 2017 Florida Building Code to anchor a new roof. S 105-11 Page 3 F AREA NO.: Deck A Building and Parapet Heights below. If no parapet exists, enter "N/A". 105-11 Page 4 91201Ia --- FOXX D e k A - 1 deck . T 1 >� Pulls( 10) - 1 3qO c 3q3'. P. 6 3n-o G, .. 3-55 F �05 Walk to DAD PT 163Z pulm . aw C� 7tificate of Calibration # KELC-536047-R , '_Kunball lectronic Laboratory, Inc. Purchase Order # ERICH �-.aH : ,yf°R^^7`'' x -px�.xu n^sx yn.•,. Eg rc"".�i }�}.r%^er rt'+�rr ��y3'r_._ �_il.',• t" ,�aC a. KIMBACL LECTRONIC LABORATO Y, INC. DUHON S ROOF CONSULTING, LLC: 8081' W 2,1 LANE 4875 PARK RIDGE BLVD HIALEAH' 'FL. 330.16 --, SUITE 108 7; ` -`f BOYNTON BEACH FL 33426 Descn tion: FORCE MEASUREN ENT SYSTEMS Manufaurer: DMCal Date: 14-Au 18 Model ;Nu� er: PT1000 Part Nu ber: PT1000 D Cal. Due Date: 14-Nov-18 bCal. Interval: 3 MONTHS R' Inge: 0-2.000 LBS Received: IN TOLERANCE Calibration Result: PASS Serial:Nu ber: 1702001 Environmental Conditions: 73 DEG F / 40 % RH Custome',A.D.: N/A Performed By: ELIU Cust.:Bar,' ode: NIA I LAGO Cust: ' ept.: N/A Procedure: SYN55 Specifications: +/- 0.25% F.S. I Cal Location: IN-HOUSE This is to certifyilthat the above listed instrument meets or exceeds all specifications as stated in the referenced procedure at the points tested (unless otherM§e noted). It has been calibralusing Measurement•standards traceable to the National Institute of Standards and Technology (NIST), or to NIST acceptedintrinsic standards of measurement, or derived by the (atlo type of seif-calibration techniques. Thls calibration is In accordance with Kimball Electronic Laboratory; Inc Quality Assurance Manual. KELI's Quality system is A2LA Accredit to ISO/IEC-17025:2006 and compliant with MIL-STO-45662A and ANSI/NCSL Z540.3-2006. TURS when, applicable are greater than or equal'to 4:1;With expanded uncertainty usl to calculate the Test Uncertainty Ratio, iwith a coverage factor of K=2 at a confidence level of approximately 95%,.unless otherwise noted. Any number ofl#actors may cause the calibration item toAdft out of calibration. before the recommended Interval has expired. Company KIM001 This report vAS'FQUN['TO:�BE"-IN TOLERANCE AT THE TIME OF CALIBRATION. D ROUTINE:CAL. NO ADJUSTMENTS REQUIRED I.D. r' Manufacturer Model/PN Description Serial Number Last Cal. Cal. Due Date '10:190 MOREHOUSE INSTRUMENT COMPANY, INC 0. PRECI:3176 / G82-101102- 27=Dec=17 31-Dec-18 nician:�-- Quality Assurance: ELIU JAVIER LAGO 14-Aug-18 1:58:24 PD1 BALCEIRO 15-Aug-18 8:37:37 PM y not be reproduced, except in full, unless'permission for the publication of an approved abstract is obtained in writing from KELI Labs., Inc. Kimball Electronic Laboratory, Inc. - 8081 W. 21st Lane - Hialeah, FL. 33016 Tel: 305-822-5792 - Toll Free: 800-393-1094 - Fax: 305-362-3125 - Web: www.kelilabs.com l'ii