Loading...
HomeMy WebLinkAboutFIELD WITHDRAWL RESISTANCE TEST RESULTS DECK CTESTING APPLICATION STANDARD (TAS) 105-98 APPENDIX A SCANNED FIELD WITHDRAWAL RESISTANCE TEST RESULTS REPORT II -f�t1�1�11t 4875 Park Park Ridge Blvd.. Suite 108 • Boynton Beach. Florida 33426 • (561) 734-3818 (Phone) • sduhonodrerookonsulting.comBlvd., Suite 108 • Boynton Beach. Florida 33426 • (561) 734-3818 (Phone) • sduhonodrerookonsulting.com SERVING FLORIDA AND BEYOND INFORMATION: Job Name: Foxx Residence Project Number: 18-2164.00 Job Address: 403 N 40th St. Pierce, FL 34947 Contact Individual at job site (if any): Area Tested: Deck C Date Tested: 9/20/2018 Report Number: 3 AGENCY/EQUIPMENT INFORMATION: The undersigned acknowledges that all testing has been conducted and results have been reported in compliance with TAS 105 or TAS 105 Appendix A Testing Agency Name: Duhon's Roof Consulting, LLC - FBPE CA#: 32207, NOA# 18-0801.02 Address: 4875 Park Ridge Blvd., # 108 Boynton Beach, Florida 33426 Telephone: 561-734-3818 Fax: Technician: Certified By: Signature & Date: N/A Erich Velzy Hector Vergara, FL P.E. License #25764 •(_ STATE OF o �/, v���ssesefeas�� Test Apparatus (Gen'l Description): Force Measurement System DMD PT1000 105-11 Page 1 J JROOF SYSTEM INFORMATION: Roof Area Height: Roof Area Dimensions: deck height (ft) largest dimension (ft) second largest dimension (ft) total roof area squares perimeter width perimeter area (see RAS 117) Area No. Deck C 31 Roof Submittal (if known): Miami -Dade NOA No. Page No. of TENER INSTALLATION INFORMATION: Is the fastener a self driller? Yes X No If yes, list the type of tool used for fastener installation: Dewalt 20V Max. Speed of Tool: 0-2000/min rpm's T INFORMATION: Number of Tests Conducted: n = 10 • 10 tests for the first 10,000 sf + 3 test for each additional 5,000 sf. • Multiply by 125N for lightweight concrete. • See Section 8.f of TAS 105 • Note the location of all tests on `Sketch of Roof, attached hereto LD WITHDRAWAL RESISTANCE TEST RECORDING SHEET No. Deck C Fastener Type: # 14 HD r to deck dimensions referenced on page 2 Fastener Manufacturer: OMG )onem to be secured: Pre -drilled? Insulation X Yes No X Membrane X If yes, Drill bit size: Anchor or Base Sheet Wood blocking Hole Depth: Metal Profiles ,ection 8.o of TAS 105 to determine number of tests (If drill bit is high tolerance, include range in 1/1000" tolerances) FAS 105-11 Page 2 585 ft' 6 sqs 3.00 ' 288 ft2 " dia. i SAMPLE s, N . , PLAN IDENTIFIE,R,j INITIAL FAmILURE LOAD (Ibt)' R � r ,FIELD ERIMET,ER OR CpRN'ER:(circle,one)�s II 1 1 594 F P (C) 2 2 591 F (P) C II 3 3 598 F (P) C 4 4 314 F P (C) Ij 5 5 575 F P (C) 6 6 590 F (P) C I' 7 7 591 (F) P C 8 8 586 (F) P C �I 9 9 553 (F) P C 10 10 517 (F) P C 1' 'ATISTICAL ANALYSIS: Mean Failure Load`. F = 550.90 lbf Sample Standard Deviation: SF = 86.86 lbf Minimum -Characteristic Resistance Force F' = 529.84 lbf tes: 1. Use of the results herein to determine the required number of fasteners for insulation attachment or an acceptable anchor or base sheet fastener spacing, as outlined in TAS 117, shall utilize the minimum characteristic resistance force (F'), determined in compliance with Section 9.f TAS 105. No margin of safety shall be applied to field withdrawal resistance test results determined in compliance with TAS 105. 2. A safety factor of 2 to 1 shall be applied to all results of laboratory testing. 3. The following pages shall be completed for each roof area and included with all Field Withdrawal Resistance Test Recording Sheets. Notes: Conclusion: This wood deck passed the TAS 105 Fastener Withdrawal Test as per the 2017 Florida Building Code to anchor a new roof. aS 105-11 Page 3 F AREA NO.: Deck C Building and Parapet Heights below. If no parapet exists, enter "N/A". jAS 105-11 Page 4 � ? r '� r. 1�•.*+-ram. �.:,-x•.. �1 ? # t Li :.}. �� ,ti,y.-�.� N,_,,,•,i • 4 i _ 1- �a�.: _,_._j... ' _l a # i 9 � 1 i _ yy,ee s a� - .s�i..—..._i_ ti.-�v.._.-.a._ ♦ � ` � ..-r-�.�S.' � 1 - ,I -_..-a..--,- l.,.s �_t.,-},s.-�� .i � 1.�. - i�: " � � I ��71j+++���'''���---```'''!'''If'''`''�'��^" r 1 F- % _ .� � '-�( '....11�•�Y3e11�.^^°'.r t I•a.•_e...�. 7j Q Y 1 - fit_ � • • � - �:..i�,.,� Y' ��- �� - _;• �-�'=9:�� M�� P ,...,�...,s„ _ of : _ _ i � ------�' . _�,f - t.,__. f � �._.,• Y i I ,�.�y : 13 .�._..,���� ' - �,,...Y. _ t Y S t { d , I S ! 4 t', 1 � 1� �� ` i �i .1.E_0.=� :¢¢w.t ,7< � ..: rV r•""'�,�i_ 71 j ^Wn"_'•-:_,'..'.'�`� �.;+�..r...�aNa. ^_i 1i �-`�Y'.-�-'_ t �.�.'�.xtw•.�+} {�..,.� ,.- { . � (. •i• I : !: tt _ I� Ta._"`.�'�:'••"- � � 'I. I 1 -� 1..� 'I� V~ ��:__•�. __!'-:^-.•I r-#� #..rr? I�...�+�....._��.—t� ... j� .�.r�:�.r)_..-.��a :yes _-_ -.'� 1-sd�,^���''.`t'.,�'.--`�R"•_ � � ,-_.,� _-� _ P w rr-„•-.t.}I.-we.,,.a• 1 -»-a.,{ •.•..--•-r. --#. I .-.-ems'-_,.�..k_.�..:.,s.�_ - y � pp +-�,• •,- -.''—' _ C41lficate of Calibrafior II p -. Ua7.R 'KimbaIl Electronic Laboratory, Inc. Purchase der # ERIC fy� .«:.., ., A' rro �k:t., F x.. j: � Fd � •..�' 1, ,,°°i. O..ti:.. S r � � - >.. . 1� JG KIMBALL LABORATO Y, INC. .. _.tir+kr,:±�� DUHON. S ROOF CONSULTING, LLC !ELECTRONIC 8081 W 2 LANE 4875 PARK RIDGE BLVD HIALEAH FL. 3.3016 " JW SUITE 108 BOYNTON BEACH FL 33426 Descry tlon: FORCE MEASUREN ENT SYSTEMS Manufae�urer: DMD Cal Date: 14-Aug-18 Model N ,1' ber: PT1000 Cal, Due Date: 14-Nov-18 Part,Nu ber: PT1000 Cal. Interval: 3 MONTHS R' nge: 0-20QO LBS Received: IN TOLERANCE Calibration Result: PASS Serial Nui� ber. 1702001 Environmental Conditions: 73 DEG F / 40 % RH Custome, ,I.D.: N/A Performed By: ELIU C.ust.:Bar ode: NIA LAGO Cust.- ept.: N/A Procedure: SYN55 Specifica ons: +/- 0.25% F.S. Cal Location: IN-HOUSE This is to.certifythatthe above listed instrument meets o1r exceeds all specifications as stated in the referenced procedure at the points tested (unless otherwise noted). It has been calibratet� lusin g`measurementstandards traceable to the National Institute of Standards and Technology (NIST), or to NI$T accepted intrinsic standards'of measurement, or derived by ffie; do type of self -calibration techniques. This calibration is in accordance with kmball ElecVonic Laboratory; Inc Quality Assurance .Manual. KELP s Quality system is A2lA Accredit to ISO/IEC 17025:2005 and'compltant with MILSTD 45662A and ANSIINCSL Z540.3-2006. TURS when appl(gble ;are greater than or equal to 4:1;.with expanded uncertainty:ysed to calculate the Test Uncertainty Ratio;�with a coverage factor of K=2 at a confidence level of approximately 95%,,unless otherwise noted. Any number oflt`actors may cause.the:calibretion item tojdrift out of calibration before the recommended Interval has expired. Company KIM001 This report VAS-FOUND-TO`BE-.:IN TOLERANCE AT THE TIME OF CALIBRATION. D ROUTINE CAL. NO ADJUSTMENTS REQUIRED i I.D. / Manufacturer Model/PN Description Serial Number Last Cal. -Cal. Due- Date 16190 MOREHOUSE INSTRUMENT COMPANY, INC 0. PRECI:3176 I G82-101102- 31-Dec-18 nician: Quality Assurance: _ ELIU JAVIER LAGO 14-Aug-18 1:58:24 PD1 BALCEIRO 15-Aug-18 8:37:37 At4 y not be•reproduced, except in full, unless'permission for the publication of an approved abstract is obtained in :writing from KELI Labs., Inc. Kimball Electronic Laboratory, Inc. - 8081 W. 21st Lane - Hialeah, FL. 33016 Tel: 305-822-5792 Toll Free: 800-393-1094.- Fax: 305-362-3125 - Web: www.kelilabs.com