Loading...
HomeMy WebLinkAboutFIELD WITHDRAWL RESISTANCE TEST RESULTS DECK D11 TESTING APPLICATION STANDARD (TAS) 105-98 APPENDIX A FIELD WITHDRAWAL RESISTANCE TEST RESULTS REPORT 4875 Park Ridge Blvd- Suite 108 • Boynton Beach, Florida 33426 • (561) 734-3818 (Phone) • sduhon@dreroofconsulting.com SERVING FLORIDA AND BEYOND INFORMATION: Job Name: Foxx Residence Project Number: 18-2164.00 Job Address: 403 N 40th St. Pierce, FL 34947 Contact Individual at job site (if any): Area Tested: Deck D Date Tested: 9/20/2018 Report Number: 4 AGENCY/EQUIPMENT INFORMATION: The undersigned acknowledges that all testing has been conducted and results have been reported in compliance with TAS 105 or TAS 105 Appendix A Testing Agency Name: Duhon's Roof Consulting, LLC - FBPE CA#: 32207, NOA# 18-0801.02 Address: 4875 Park Ridge Blvd., # 108 Boynton Beach, Florida 33426 Telephone: 561-734-3818 Fax: N/A Technician: Certified By: Signature & Date: V4 Erich Velzy Hector Vergara, FL P.E. License #25764 Test Apparatus (Gen') Description): Force Measurement System DMD PT1000 AS 105-11 Page 1 'ILDING/ROOF SYSTEM INFORMATION: Area No. Deck D Roof Area Height: deck height (ft) 10 Roof Area Dimensions: largest dimension (ft) 40 second largest dimension (ft) 12 total roof area 454 ft2 squares 5 sqs perimeter width 3.00 ' perimeter area 276 ft2 (see RAS 117) Roof Submittal (if known): Miami -Dade NOA No. Page No. of FASTENER INSTALLATION INFORMATION: Is the fastener a self driller? Yes X No If yes, list the type of tool used for fastener installation: Dewalt 20V Max Speed of Tool: 0-2000/min rpm's EST INFORMATION: Number of Tests Conducted: n = 10 • 10 tests for the first 10,000 sf + 3 test for each additional 5,000 sf. • Multiply by 125% for lightweight concrete. • See Section 8.f of TAS 105 • Note the location of all tests on `Sketch of Roof', attached hereto FIELD WITHDRAWAL RESISTANCE TEST RECORDING SHEET krea No. Deck D Fastener Type: # 14 HD Refer to deck dimensions referenced on page 2 Fastener Manufacturer: OMG Component to be secured: Pre -drilled? Insulation X Yes No X Membrane X If yes, Drill bit size: Anchor or Base Sheet Wood blocking Hole Depth: Metal Profiles See Section 8.o of TAS 105 to determine number of tests (If drill bit is high tolerance, include range in 1/1000" tolerances) AS 105-11 Page 2 " dia. iE� SAMPLE NO; PLAN°IDENTIFIER INITIAL FAILURE LOAD .""�^ (Ibtj "Q"' :„ d . , r i,�FIELD, PERIM_ET_ + r " A � ER OR"CORNER�(cxicle".oue)"` `" " 1 1 391 F (P) C I'I 2 2 324 F P (C) 3 3 54 F (P) C 4 4 391 F P (C) 5 5 343 F P (C) 6 6 564 F (P) C III 7 7 408 (F) P C L 8 8 481 (F) P C 9 9 118 (F) P C 10 10 376 (F) P C STATISTICAL ANALYSIS: Mean Failure Load: F = 345.00 lbf Sample Standard Deviation: SF = 153.58 lbf Minimum -Characteristic Resistance Force F' = 316.99 lbf Dotes: 1. Use of the results herein to determine the required number of fasteners for insulation attachment or an acceptable anchor or base sheet fastener spacing, as outlined in TAS 117, shall utilize the minimum characteristic resistance force (F'), determined in compliance with Section 9.f TAS 105. No margin of safety shall be applied to field withdrawal resistance test results determined in compliance with TAS 105. 2. A safety factor of 2 to I shall be applied to all results of laboratory testing. 3. The following pages shall be completed for each roof area and included with all Field Withdrawal Resistance Test Recording Sheets. Notes: Conclusion: This wood deck passed the TAS 105 Fastener Withdrawal Test as per the 2017 Florida Building Code to anchor a new roof. AS 105-11 - Page 3 iC F AREA NO.: Deck D Building and Parapet Heights below. If no parapet exists, enter "N/A". fAS 105-11 Page 4 IC' + j MEW- p q _��l.a�,�.� (1�I •b........+� i ,,.'..`.'.�� ' �'f � ; -1+•• �� � r �7 -.-it _ _''� - _ i.. �7 � , �. �' j a..n..^...•.r..' �d 1' Rfw.... 7 ...ae!. �. � ��/Alti/� r� AAA V ' :. ( i T. , �� �1•y ''I, ; _ Y _ _ F+! Yp_ _ y i `^�Tp^"�:�-.....:.... - �"•' q! "—'��^ . i � - #"`, �ii � .:.�. � .r _ fie...._. p 1 -, T-1 , 3' A _@ _'1 LF kk 33 1 yy 4 �. i . ' �.�,�.� ai.-�'-' a.•�.<�..�v.�.-.os•--�'�<.� :._-.:.,.•�.ti.� f ;-.-,v . :�.r�.�.w...... � - mr.sa�.. �'s� -- �' -{4�1 ' �_......},..,..: � 99 C,-�tificate of Calibratioia ' # KELC-536047-R - 1.imball lectronic Laboratory, Inc. 4 Purchase Order # ERICH NOW ;a .�-»''�""-n fr-•�;.r7 �-.,-,.r-,.,��,� .,-*7•;Tr^--. .� : .s^, ��j�, �s .—..,-, KIMBALL ELECTRONICrLABORATO Y, INC. DUHON S ROOF CONSULTING,-LLC_ 8081- W 2 LANE 4875 PARK RIDGE BLVD HIALEAH FL."33016 SUITE 108 tt4t294835�7371 BOYNTON BEACH FL 33426 Desch )tion: FORCE MEASUREIV ENT SYSTEMS �' Cal Date: 14-Au 18 Martafao user: DMp g- Model,Nui ber•: PT1000 Cal. Due Date: 14-Nov-18 Part Nu ber: PT1000 Cal. Interval: 3 MONTHS Rc' ge: 0-2000 "LBS Received: IN TOLERANCE Calibration Result: PASS Serial:Nu m ber. 1702001 Environmental Conditions: 73 DEG F / 40 % RH Custome ,I.D.: N/A Performed By: ELIU cust..Bar ode: NIA ! LAGO bust.. 1 pt.: N/A Procedure: SYN55 Specifca ions: +/- 0.25% F.S. Cal "Location: IN-HOUSE This is to cer4fj'Urat the above listed instrument meets of exceeds all specifications as stated in the referenced procedure at the points tested (unless otherwise noted). it has been "calibrot f using measureme6t,-standards traceable to the National.lnstitute of Standards. and Technology (NISI), or to NISI acceptedintrinsic standards of measurement, or derived by the do type;of"self calibration techniques. This calibration Is in accordance with Kimball Electronic Laboratory; Inc Quality Assurance Manual: KELI's Quality system is A2I A Accredit to ISOII f 17D25 2005 and compliant, vith MIL-STD-45662A and ANSVNCSL Z540.3-2006. TORS when applicable;are greater than or equal'to 4:1; with expanded uncertainty-u d "to calculate the Test Uncertainty Ratio'Iwith a coverage factor of"K=2 at a confidence level of approximately 95%,.unless biherwise noted. Any numbdf of actors may cause the.calibration "item to drift out of calibration before the recommended Interval has expired. THIS `UNITjWAS--FQUND-TO`BE .JN TOLERANCE AT THE TIME OF CALIBRATION, PERFORM D ROUTINE.CAL. NO ADJUSTMENTS REQUIRED . _.. 11 Company ._ .. . .. I.D. _., . ,,.. - -I . Manufacturer Model/PN Description Serial_Number Last Cal. Cal. Due Date KIM001 i 10100 MOREHOUSE INSTRUMENT COMPANY, INC 0. PRECI,c3176 / GB2-101102- 27 Dec 17 31-Dec-18 `Tec nician: �' Quality Assurance: ELIU JAVIER I LAGO 14-Aug-18 1:58:24 PD1 SALCEIRO 15-Aug-18 8:37:37 Ali This report rry not be reproduced, except.in full, unless'permission for the publication of an approved abstract is obtained in writing from KELI Labs., Inc. Kimball Electronic Laboratory, Inc. - 8081 W. 21 st Lane - Hialeah, FL. 33016 Tel:"305-822-5792 - Toll Free: 800-393-1094 - Fax: 305-362-3125 - Web: www.kelilabs.com j 1