Loading...
HomeMy WebLinkAboutSCREEN ENCLOSUREREVISIONS Category 1. 2. Basic Wind Speed, Table 1609C, State of Florida Debris Region & Basic Wind Speed, Paragraph 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed, VuLT=150 MPH _ Exposure Category, Paragraph 1609.4.3 : B Applicable Codes, Regulation and Standards 1. The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. -2,-AAASM-35andSpecificafionr-for-AluminumStructure-Rart_1-A of thea9lumirwm. Design Manual prepared by The Aluminum Association, Inc. Washington, D.C., 2010 Edition 3. ASCE 7-10 General Notes: 1. The contractor shall verify all dimensions prior to construction 2. All work shall comply with all local and regional ordinances. 3. Any deviation from this plan shall be reviewed by the engineer of record and is subject to approval. Specifications The following specifications are applicable to this projects : 1. Where concrete specification are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable. 1.1. Concrete shall conform to ASTM C94 for following components: 1.1.1. Portland Cement Type 1, -ASTM C 150 1.1.2. Aggregate - Large Aggregate 3/4" max - ASTM C 33 1.1.3. Air entraining +/- 1 % - ASTM C 280 1.1.4. Water reducing agent - ASTM C 494 1.1.5. Clean Potable water 1.1.6. Other admixture not permitted 1.2. Metal accessories shall conform to: 1.2.1. Reinforcing Bars - ASTM A615, grade 60 1.2.2. Welded wire fabric-ASTM A185 1.3. Concrete slump at discharge per chute not less then 3" or more than 5". Water added after batching is not permitted. 1.4. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2 and 3 including hot weather recommendations. 1.5. Moist cure or polyethylene curing permitted. 1.6. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. 1.7. Concrete shall be placed over polyethylene vapor barrier. 1.8. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 2. Aluminum extrusions shall be 6005 T5 Alloy. 3. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plate to ASTM B633, or stainless steel series "300". 4. All Self Mating Beam Sections are to be stitched with either#14 screws 6" from end 24" on center or #12 screws 6" from end 12" on center. S. Screened enclosures containing swimming pools shall comply with the applicable requirements of FBC R4501.17 Residential Swimming Barrier requirements. 6. Door location shall be determined by contractor in the field. 7. When installing pavers over concrete slab or footing which are supporting aluminum members, such as continuous screen tracks or upright, the pavers must be bonded to the concrete with an epoxy, thinset, or 3,000 PSI grout to ensure full positive contact with concrete. 8. All flashing and waterproofing shall be provided by the contractor. 9. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. Foundation Deslgn: Existing 8"x8" Footer and 4" Slab Existing concrete. No additional concrete footing is required to resist the loads imposed by the proposed construction if the existing footing is in sound condition, free from structural cracking, spelling, or other deterioration. Roof Type Screen Size MANSARD 18 / 14 MESH ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS SELF MATING BEAM (SMB) THE PORCH FACTORY BEAM (PFB' 2x2: 2x2"x0.040" 2x4SMB: 21x4'x0.044"x D.10D" 3.75PFB: 2x3.75'x0.05D" 2x3: 2"x3"x0.050' 2%SSMB: 2'x S"x0.05':x 0.100' 5.75PFB: rx5.75'x0.05S" 2x 4: 2'x 4"x 0.050' 2x66MB: 2"x6" x 0.050'x 0.121r 6.75PFB: 2'x6.75"x0.057" 2 x 5: 2' x S' x 0.050" 2x7SMB: 2" x 7" x 0.057" x 0.120" 2x 6 SMB: 2"x6"x0.072'x0.124' 2x D SMB: 2"x9"x 0.072"x 0.124" �: KNEE BRACE OPEN BACK SECTIONS 1 x 2: 1: x2" x 0.040" 2x 10 SMB: 2"x 10'k0.092"x 0.398" 1 x 3: 1' x 3'x 0.04S' MINIMUM FASTENER EDGE DISTANCE:W MINIMUM FASTENER 6PACINO: 3/4' SNAP SECTIONS 2x2Snap: 2"x2'x0.045" CONCRETE SCREW ANCHOR: SHEET MATEL SCREWS(SMS): 2 x 3 Snap: 2"x 3"x 0.050" SIMPOSONTRENHDOREQUIVALENT rrWBUILDEx OREQUIVALENT 2x4Snap: 2x4"x0.045' HOST GUTTER ,0NO LED FASTENERS OR ATTACHMENTS AIE THE RESPONS181UTY OF THE CONTRACTOR OF RECORD THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES, NOTE: THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES. DRAWING NOT TO SCALE. USE DIMENSIONS GIVEN. CABLE BRACING MAY TERMINATE AT SLAB IN DIFFERENT LOCATION. MAINTAIN ANGLE PER DETAIL. ST. LUCIE COUNTY BLTLDPTG D ,.SICN RE,VIEN 'ED FOR C LS C� - t REVIEWED Y DATE ?RUST BE KEPT ON JOB PLANS AND PE C NO XSpECTION WILL BE MADE. WW W DA U) 0 /JJ V W W WWN ♦V♦A V♦ C4 e a p N t M o N C •OV•On d`e'ah y !V 6 5 U • o� p�DO OOOpp� v� �U6 �d' Edward Roske, N0. 0 8 $ A�Of D�OOOpO� 0® SHEET File Co T_ u7 M .a LL u a V. O LL REVISIONS 1/8" x 2" x 2" EXTRUDED-----' XTRUDED (4) #14 x 3/4"SMS ANGLE 5052 H42 ALLOY 0 0 INTO POST - -- — -- BRICK PAVERS BONDED TO CONCRETE (8) #14 x 3/4" SMS ' O Z = Z - ---- - - ♦_,_�—♦-�--'� 118" PLATE ON 45" ANGLE -- • -gyp-W — - - --- - - - - 063_WAtUMINU -_ SLABIFOOTING ° a • d: •• _ w ♦ ' SEE PLAN d d ' O w a O O O O SIDE VIEW O O (4) #14 x 3/4"SMS 2" x 2" DJ EYE BOLT FOR O BRICK PAVERS. MAY NOT BE INTO POST CABLE TENSION O PRESENT. FOLLOW (1) 3/8" DIA.CONCRETE ANCHOR MINIMUM SCREW ANCHORS CONCRETE EMBEDMENT (21/2" CONC. EMBED) 1" x 2" BASE PLATE ANCHORED TO CONC W/ 1/4" PERIMETER — CONCRETE SCREWANCHOR FRAMING (MIN. 1 1/4" EMBED) 6" MAX EACH SIDE OF POST AND 24" O.C. MAX ' • , d Ll' . d FRONT VIEW DJ-1 DOOR JUMB TO CONCRETE W/PAVERS DETAIL A-2 SCALE: NTS 1"x 2" O.B. FASTENED TO CORNER POST Wl #12xl 1/2"SMS AT 6" FROM TOP 8 BOTTOM RAILS. TYPICALLY @ 24" O.C. x 2" x 2" EXTRUDED ANGLE 5052 CORNER POST F1/8" H-32 ALLOY EA CORNER #14 x 2' MS INTO P ST & (1) 3 8 D/IA) CONCRETESCREWANCHORINTO CONCRETE (2) #10 x 11/2"SMS THRU SCREW BOSSES BRICK PAVERS. MAY NOT BE v z PRESENT. FOLLOW ANCHOR MINIMUM o v w - CONCRETE EMBEDMENT . , .d ? SLAB/FOOTING - SEE PLAN SIDE VIEW �x z N a �2 CONCRETE POST W/ 1"X2" @ (4) #14 x 3/4" SMS BACKSIDE INTO POST 3/8" x LENGTH AS REQUIRED FOR 21/4" EMBED CONCRETE SCREWANCHOR INTO CONCRETE 1"x 2" BASE PLATE ANCHORED TO CONC Wl 1/4° CONCRETE SCREWANCHOR (MIN.11/4" EMBED) 6" MAX EACH SIDE OF POST AND 24" O.C. MAX d ♦d 64 • 3 0. - FRONT VIEW CP-1 CORNER POST TO CONCRETE WAVERS DETAIL A-2 SCALE: NTS DSL COMPRESSION SLEEVES 1/8" S.S. CABLE 1 1/4"x5518"x118"ALUM. FLAT BAR. 6063-T6 ALUM. W/ (2) 318" DIH. x 2 3/4" -- - EMBEDMENT CONCRETE ANCHORS -- - 0 mw 8 BRICK-PAVERS-.=MAAY'NOTBE- --- --•, - — --� ----- — - --- - -- — - -�- — _ M - .a PRESENT. FOLLOW Z Z ♦ • ANCHOR MINIMUM -• . •. ' F^j CONCRETE EMBEDMENT "41 , - p • 4d a a nz O ICI N . M^ �r t.cc SLABIFOOTING I� SEE PLAN Z r Z W ... %N 1/8° S.S. CABLE 2'k `rye O b y W w -e pa E q O O o 11/4"x5518"x118"ALUM. FLAT BAR. 6063-T6 ALUM. µ0 t 'Eb Ia)l a d ♦ N v '2 :4 •o •. W H-2 CABLE CONNECTION AT CORNER A-2 SCALE: NTS 1/8"X2"X2" EXTRUDED - ANGLE 5052 H.32 ALLOY EA SIDE BRICK PAVERS ONTO CONCRETE ud a .E.. .-. SLAB/FOOTING o d . - '< ♦, d SEE PLAN e- e • e d SIDE VIEW (1) 318" DIA CONCRETE SCREW ANCHORS — (2 IW CONC. EMBED) BRICK PAVERS (1) It? D64 THRU BOLT WWLOCK JAM NUT -IN LIEU OF NYLOCK JAM NUT. JAM NUT w/THREADLLOCKER MAY BE USED TIGHTEN TO CONTACT. DO NOT OVER TIGHTEN BRICK PAVERS. MAY NOT BE PRESENT. FOLLOW ANCHOR MINIMUM CONCRETE EMBEDMENT 1"x2" BASE PLATE ANCHORED TO CONC WI 1/4" CONCRETE SCREW ANCHOR (MIN. 1 1/4" CONC. EMBED) 6" MAX EACH SIDE OF POST o. a SLAB/FOOTING SEE PLAN a' a FRONT VIEW J B 12" x 4" OR LARGER UPRIGHT TO CONCRETE W/PAVERS DETAIL p_2 /SCALE:NTS (2) 3/8" DIA. x 3" EMBEB-/ LSLAB/FOOTING CONC. SCREW ANCHOR SEE PLAN H-1 CABLE CONNECTION AT FOUNDATION A-2 SCALE:NTS (4) #10 x 1 1/2" SMS SCREW BOE SNA' SELF -MATING E C IEMBER C PURLIN OR GIRT BEAM OR POST DETAIL A-2 SCALE: NTS 0) V W d �J co 10 E � E o, O < = a co) J IL 1 d 0 U = ID C a ZIL °=mLL 0) V _ = O Z I.t9tia W N W m L° � ♦♦V1AA u v "O L a �aaa Otjnnn,._ No. �i 4 ^ QQ o. CW7 V 0 0 A F�i�'fly .'2 REVISIONS 6" WIDE x 0.125" "Z" BRACKET @ EACH BEAM ATTACHED TO FASCIA W/ 3/8" x 3" LAGS (3 PER BRACKET) AND (1) 318" X 3" LAG @ 24' O.C. AT GUTTER NOT NEEDED IF GUTTER HAS SPLINE GROOVE. OTHERWISE, 1"x 2' x 0.044" OPEN BACK W/ (2) #10 x 212"SMS THRU BEAM INTO SCREW BOSSES (1) #10 x I l2" SMS 6" O C O O MATING ELEMENT 1/8"x2'x2"x2"ALUM. ANGLE W/ (4) #14 x 314. SMS EACH FLANGE EACH SIDE OF BEAMIPURLIN WHEN BEAMIPURLIN IS LARGER THAN GUTTER, 2 1/8" x 1 1/8" x 0.062" (MIN.) ALUM RECEIVING CHANNEL W/ MIN. (2) #12 x 3/4" SMS NOTE: .(2) 3/8" DIA. x 4" LAG SCREWS FOR _ SPANS GREATER THAN 30'-0" CONTRACTOR TO VERIFY 2" x 44 FASCIA- IF LESS THAN 2" x 4' FASCIA, 2" X 4" SUB FASCIA SHALL BE 5"SUPER PLACED OVER, LENGTHEN GUTTER LAG SCREWS TO FULLY PENETRATE SUB FASCIA, IF OTHER FASCIA, ADD 2" x 4" PT FASCIA nd 12" LAG BOLTS -112' INTO TRUSS 0.062"BACKING PLATE TAILS -COUNTERSINK ON INSIDE OF GUTTER FLUSH. WHEN INSTALLING 12"LAG SCREWS. PRE -DRILL W13/8" DRILL TO PREVENT SPLITTING G GUTTER BRACE & MATING ELEMENT ATTACHMENT DETAIL A-3 SCALE: NTS MEMBERSIZE EDGE"C" 2X4 12" 2X5 1" 2X6 - 2X10 1112" FLASHING —\ EAVE RAIL (SEE A-1 FOR SIZE) INTERNALLY SCREW THRU BEAM W/(3) 010 x 112" SMS 1"x FASTEN TO EAVE RAIL W/ # 10 x 11/2" SMS 6" FROM UPRIGHT & 24" O.C. (1) 1/2" DL4. x 212" THRU BOLT W/ NYLOCK JAM NUT - IN LIEU OF NYLOCK JUM NUT. JAM NUT W/ THREADLOCKER MAY BE USED INSTALLATION REQUIREMENTS : BOLT IS TO BE INSTALLED AS TO - NOT DAMAGE BASE MATERIAL DO NOT OVER TIGHTEN. 2"x SMS BEAM NOTCHED OVER UPRIGHT (SEE A-1 FOR SIZE) WOOD: #10 x 3' WOOD SCREWS, 6" FROM GIRT & @ 12" O.C- CONC. 1/4" DIA. x W CONCRETE SCREW ANCHOR, 6" FROM GIRT & @ 24" O.C. (4) #10 x l l2" INTO SCREW BOSS x 2" HOLLOW SECTION #10 x 3" WOOD SCREWS, 6" FROM GIRT & @ 12" O.C. 2" x HOLLOW SECTION CONC. GIRT OR PURLIN 1/4" DIA. x 3" CONCRETE SCREW ANCHOR, 6" 1" x 2" FROM GIRT & @ 24" O.C. C-1 1X2 TO HOST STRUCTURE DETAIL A-3 SCALE: NTS Note - Orientation may be different. via" anco_uan r_� iecor 2" x SMS UPRIGHT (SEE A-1 FOR SIZE) NOTES: 1. SEETHE NOTE BELOW FOR SCREWS SPACING. THE NUMBER OF SCREWS SHOWN ARE FOR ILLUSTRATIVE PURPOSES. DO NOT COUNT SCREWS ON DRAWING. 2. GUSSET DIMENSIONS AREA MINIMUM (2) REQ'D - (1) EA SIDE OF BEAM - MAY BE INTERNAL OR EXTERNAL 3. AS BEAM SIZE CHANGES, ADD OR SUBTRACT SCREWS TO MAINTAIN 11/4" C/C SPACING. 4. GUSSET LENGTHS REMAIN CONSTANT WIDTHS CHANGE TO MATCH BEAM SIZE. rD UPRIGHT TO BEAM CONNECTION A_3 SCALE: NTS kE TYPICAL INTERNAL OR EXTERNAL GUSSET DETAIL- RIGID MEDIUM A-3 SCALE: NTS GUSSET PLAT PER ESERIES DETAIL #2 DETAIL #1 .- SELF MATING BEAM CONTRACTOR TO INSTALL (2) #14 x 2" SMS THRU BRACE INTO BEAM THRU GUSSET PLATE CONTRACTOR SHALL RUN 1/4" THRU BOLT TO ATTACH W/ NYLON WASHER & STAINLESS STEEL NUT H-3 ROOF BRACING CONNECTION DETAIL A-3 SCALE: NTS 2 x PURLIN - NOTCH BOTTOM FLANGE TO OVERLAP UPRIGHT EAVE RAIL INTERNALLY SCREWED THRU UPRIGHT WITH (3) #10 x 2" SMS INTO SCREW BOSSES 1' x 2" x 0.044" OPEN BACK INTERNALY- SCREW TO UPRIGHT Wl (2) #10 x 112" SMS & FASTEN TO EAVE RAIL W/ #10 x 112" SMS SPACED 6" FROM UPRIGHT AND AT 24" O.C. 1/8" x 2" x 7' 6063-T6 ALUMINUM STRAP, WITH (2) #10 x 5/B" SMS EACH SIDE OF BEAM F SLOPED PURLIN CONNECTION DETAIL A-3 SCALE: NTS d W m ` J V♦ Q E U) O It = J3 M J V Q LC , d 0 y C 0 vac W a=mLt d Z v LLI h INa W d li a 'V c° a m00 aug'? - No.e7FAMMAW-a '6 coO8 0O� O 4 0 M�rP- 00� DO Ffle C7 I .•A-3