HomeMy WebLinkAboutNOA - EDGE LOC- — -- MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEP IRTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
N ,TICE OF ACCEPTANCE(NOA) www.miamiaade.Eov/economy
1
14 aylor Roofing SCANNED
30211 'elton Drive BY
Ft. ierce, FL 34982 sit, iWOt�
SCOPE: ��✓
Thi L�NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
doeentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
use in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
Thi NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In iami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or ri aterial tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
ma ufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of s ch product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
dete I ined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of t �e applicable building code.
Thi product is approved as described herein, and has been designed to comply with the Florida Building Code
incl ding the High Velocity Hurricane Zone of the Florida Building Code.
: Edge-Loc 1.0 x 16" wide x 24 ga. Steel Panel over .Wood Deck
1G: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
"Miami -Dade County Product Control Approved", unless otherwise noted herein.
H]PNEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in t #e applicable building code negatively affecting the performance of this product.
%IINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
ials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
OA shall be cause for termination and removal of NOA.
A VERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
exp ation date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in i s entirety.
"ECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
be available for inspection at the job site at the request of the Building Official.
Irevises NOA No. 13-1015.05 and consists of pages 1 through 5.
q submitted documentation was reviewed by Juan E. Collao, R.A.
NOA No.: 14-0416.01
07/1 2,0/ / Expiration Date: 01/09/19
Approval Date: 06/05/14
Page 1 of 5
Inc.
ASSEMBLY APPROVAL
Roofing
Metal, Panels (Non -Structural)
Steel
Wood
lesign Pressure —101 psf
NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
duct Dimensions Specifications Description
1.0 Length: various TAS 110 Corrosion resistant, prefinished, coated
Width: 16" galvanized, galvalume, standing seam, metal
Height: 1" panels.
Thickness 0.024" (24 ga.)
Min. Yield Strength: 50 ksi
;es Length: varies N/A Corrosion resistant, prefinished, coated
Width: varies galvanized, galvalume, standing seam, metal
Thickness 0.024" (24 ga.) panels.
IENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
9 433X515 ASTM B 117 11/21/11
433B173 ASTM D 4587, ASTM G 23 11/21/11
Engineering & Testing 72-0314T-06A-C TAS 125 03/24/07
iugh Engineering and T158-07A TAS 100 04/14/07
.a Inc.
NOA No.: 14-0416.01
Expiration Date: 01/09/19
Approval Date: 06/05/14
Page 2 of 5
ASSEMBLIES:
Sys
Dec
Decc
Slol
Ma
Pre
i m: Edge-Loc 1.0 Panel x 16" Wide x 24 ga. Steel
Type: Wood, Non -Insulated
Description: New Construction 19/32" or greater plywood or wood plank, or for re -roofing 15/32" or
greater plywood.
a Range: 2: 12 or greater
'mum Uplift See Table A below
sure:
Deck
Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d ring
shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum
15/32") The above attachment method must be in addition to existing attachment.
Un
erlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4"
side -lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps
and 12 gauge,1 1/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered
rows 12" o.c. in the field of the roll. Or, any approved underlayment having a current NOA.
Fir
Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation # 1.
Vail
eys: Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with PAC Contractors Association's current published installation instructions.
Mel
al Panels and Install the "Edge-Loc 1.0 Panel" and accessories in compliance with the current published
Acc
ssories: installation instructions and details in PAC Contractors Association's Installation Manual.
Flashings, penetrations, valley construction and other details shall be constructed in
compliance with Roofing Application Standard RAS 133.
Panels shall be secured at a spacing listed below in Table A with #10-13 x 1" pancake head
screws of sufficient length to penetrate through the sheathing a minimum 3/16 of an inch.
The adjacent panel shall overlap and be secured to each other when The female rib of panel
is snapped over the male rib of panel.
TABLE A
MAXIMUM DESIGN PRESSURES
Roo
Areas
Field
Perimeter and Corner
Ma
mum Design Pressures
—59.75 psf
—101 psf
Ma
''mum Screw Spacing
16" o.c.
6.75" o.c.
1.
xtra olation shall not be allowed
NOA No.: 14-0416.01
Expiration Date: 01/09/19
Approval Date: 06/05/14
Page 3 of 5
S
1.
2.
3.
4.
6.
LIMITATIONS
Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended corners and corners).
Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in
Roofing Application Standard RAS 133.
All panels shall be permanently labeled with the manufacturer's name and/or logo, city, state, and the following
statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control
Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or
model.
All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
Panels may be shop or jobsite roll formed with machine model #5521095 or 7031100 from PAC Contractors
Association.
NOA No.: 14-0416.01
Expiration Date: 01/09/19
Approval Date: 06/05/14
Page 4 of 5
Z
PROFILE DRAWINGS
16"
Fastener Relief, Stiffening Ribs and Striations are Optional
Field Condition
EDGE-Loc 1.0 PANEL SYSTEM
END OF THIS ACCEPTANCE
NOA No.: 14-0416.01
Expiration Date: 01/09/19
Approval Date: 06/05/14
Page 5 of 5