HomeMy WebLinkAboutEVALUATION REPORT - METAL ROOFINGJ Gun SUPPLY F• A4dPdUFRCTUttiNG Product Evaluation Report - GULF COAST SUPPLY & MANUFACTURING, LLC 26 G . SV Crimp Roof Papel over, 15132°- Plywood Florida Product Approval #11651.13 R3 Florida Building Code 2017 Per Rule 61 G20-3 Method: 1 —D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & fWanufacturing, L C. 14429 SW 2nd Place, Suite G30 `�,,,. Newberry, FL 32669 p,NtEL� S . �� Engineer Evaluator: Dan Kuhn, P.E. #75519 Florida Evaluation ANE ID: 10743 Validator: Locke Bo ��, ,den. P E. t;'4970f4 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluatuan Report Pages ®— 5 11651.13 R3 -OCTOBER 5, V.'\GEN'°'S''> � s No, 75519 � 1 0• STATE OF% : Q 'G %% ,,i Iif 6666ti Ulf i 5UPPL. & Pe1ANUFraClURfNG Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Product Description: 5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage, through fastened roof panel with fasteners in the panel flat over minimum 15/32" plywood decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section.1507.4.3. Paint Finish Optional Yield Strength: 80.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Cade 2017, Section 1507.4.3_ Panel Dimension(s): Thickness: 0.018" Minimum Width: 24" Coverage Rib Height: 3/9" Major Rib Panel Fastener: #9-15x1.5" with sealing washing in the flat of the panel or approved equal, 1/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Substrate Description: Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017. Design Uplift Pressures: 11651.13 R3 e OCTOBER 5, 2017 Table "A" Maamurri )c�tal Up(iDest Pssure 1`25 psf' 131'O psr �, Ja Fastener Pattern 12"-12" 9.5"-2"-9.5" t'asterer Pattrn Spang E 16' O C P ; YAl b'0 Design Pressure includes a Safety Factor = 2.0. 0 �. c rc--�.'}{..,x}.fit--�;za—`"y { _{_�''u=^�-}.+` j• y r ��';F e�'`'� '1- �,. Gulf SUPPLY & A.9AitiUFACTURlPlG • GA,Sy • PR •• • ••s Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: v UL 580-06 - Test for Uplift Resistance of Roof Assemblies UL 1897-12 - Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 117-0053T-05 & 117-0331 T-08 2. Certificate of Independence By Dan Kuhn, P.E. (FL# 75519) ® Kuhn Engineering, LLC (FBC Organization # ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details_ Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. 11651.13 R3 • OCTOBER 5, 2017 Is Gulf SUPPLY & n$,itNU,ACTUR.RJ& Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 ' using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High.Velocity Hurricane Zone. 11651.13 R3 u OCTOBER 5, 2017 Gu f -7T 'INfj SUPPLY & MANUFACT1,11, Id ENG`NEER LOAD TABLE 26 Ga. 5VCrlmp Roof Panel over 15/32" Plywood `2oriip,Rdpf; V�/rtd Speeds 120 ' Ings Fiauin$ga Raaf�Mean HIght`�;20' U";rRoof''Slope 2"/.1 ` 1' 18C? ph,.Expostlre C, Ris. Cate 'a!Y"l "• -Rc osed Building; bafsed orr Florida Bultdmg Cotle 2037 5 ^ .i 130 140 150 160 170 180 W�120 'Np FASTENER SUBSTRATE SPEED (MIN. 1/4" (MIN. 15132") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING f E 1 #9�15x1 5" ' � 16" Tl(PE 1 1!6" TYPE 1 � 96 TYPE 1 TYPE�1 16"TYPE 1, 76" TYPE 1 76 TVPE 1: ' Z4 t r IV,,._, Plywoodk�-`' r ,16" ZONE 2 #9-15x1.5" Plywood 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16 TYPE 1 ,,I{{ 3 #95X1 5" PI`yWood 1G TYPE 1 ifi' T)fPE t "1 1bTYPE- IS TYPE 1 1b". TYPE 1 ib TYPE 2 96" TYPE 2 ZfJ�tE � 1.) PANEL DESCRIPTION: 5V CRIMP, MIN. 26 GA., GRADE 80, 24"COVERAGE. i 2.) P11 NEL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER W/ MIN, 1/4" PENETRATION. 3.) IIIIAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: -94.25 PSF@ 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN, -131.0 PSF Ci 16" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.) Pfy'iYWOOD DECKING: MIN. 75/32" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. 5.) �?OF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 7-10 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING 6.) LDAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE (KD = COD 2017. 2 HIP ROOF ZONE 14-1 Note: Dimension (a) is defined as 10% of the minimum width of the building or a 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be less than either 4% of the minimum width of the building or:) feet. I RIDGE i � I � l ; ZONE 1 \ ti f ------------- ti- EAVE ZONE 2 GABLE ROOF =— �-----------------.— ,a � � I \ /--RIDGE------------ j +------ -----------------4- �fa - I ZONE 1 I \ I —ZONE3 '—EAVE 11651.13 R3 a OCTOBER 5, 2017 TYPE FASTENER PATTERN (1) #9-15 x 1-1/2" HWH w/Sealing Washer 1211 1211 At Panel Lap TYPE 2 FASTENER PATTERN (1) #9-15 x 1-1/2" HWH w/Sealing Washer t21I�9.5" �'�-9.511 2"1 - - `` fir.✓ r�"'y y''r-�-tr� �` '� 63UIf suprLY & MAD!UFACT€lRING TYPE 1 FASTENER PATTERN (1) #9-15 x 1-1 /21' HWH W/Sealing Washer -- 1211 1 211 At Panel Lap TYPE 2 FASTENER PATTERN -(1) #9-15 x 1-1 /2" HWH W/Sealing Washer 2" - 9.5" 11 9.5'° --- 2111 �1 G E NScc = * • No. 75519 STATE OF : Q ip • • �� o 10 11651.13 R3 u OCTOBER 5, 2017