HomeMy WebLinkAboutPRODUCT APPROVAL - METAL ROOFINGda Building Code Online
Page 1 of 5
ME
kt" —is
tt
.n,
BCIS Home Log In User Registration ^Hot Topics j Submit Surcharge Stats & Facts Publications FBC Staff i BCIS Site Map Links j Search
¢ Product Approval
Uj,i j�j, USER: Public User
Produc_.,t Ap,�roval Menu > Product or Application Search > Application List > Application Detail
FL # FL11651-113
Application Type Revision _
Code Version 2017
Approve
"
Application Status Approved f6_1 VL4.V`� ` v ��� ��S
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FILE COPY
Gulf Coast Supply & Manufacturing, LLC.
4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352) 498-0778
Info@gulfcoastsupply.com
Eng David
info@gulfcoastsupply.com
David Eng
14429 SW 2nd PI
Ste G30
Newberry, FL 32669
(352)498-0778
Info@gulfcoastsupply.com
David Eng
14429 SW 2nd PI
Ste G30
Newberry, FL 32669
(352) 498-0778
david.eng@gulfcoastsupply.com
Roofing
Metal Roofing
SCANNED
at Lucie County
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Daniel S. Kuhn
the Evaluation Report
Florida License PE-75519
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/12/2024
Validated By Locke Bowden P.E.
W! Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL11651 R3 COI CertofIndependenc� 2017-10-09,.pdf
Standard
Year
FM 4471
1992
TAS 100
1995
TAS 110
2000
TAS 125
2003
UL1897
2012
UL 580
2006
://www.floridabuilding.org/pr/pi_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2f r... 4/ 16/2018
Building Code Online
Page 2 of 5
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Go to Page °ie�'
Method 1 Option D
10/10/2017
10/12/2017
10/17/2017
12/12/2017
FL # IModel, Number or Flame
11651.1 0.032" Aluminum 5V Crimp
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.SPSF
Other: -108.5 psf @ 12" o.c. Install per manufacturers
details. Not for use in HVHZ Zones.
a Page 1/ 2 a It
Description
Min 0.032" 5 V Crimp Aluminum Roof Panel over 15/32"
Plywood
Installation Instructions
FL11651 R3 II FL11651 1 R3 Metal Roof Panel Detail-
signed.p_df
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 1 R3 0325vCnmp 15-
32Plywood NonHVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.2
0.032" Aluminum Gulf Lok
Min 0.032" Aluminum Gulf Lok 16" Wide Roof Panel over
15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 II FL11651 2 R3 Metal Roof Panel
Approved for for use outside HVHZ Yes
signed. A
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-116.OPSF
Created by Independent Third Party: Yes
Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0
Evaluation Reports
psf @ 5 3/16" o.c. fastener spacing. Install per
FL11651 R3 AE FL11651 2 R3 032Gulfl-ok 16 15-
32PIywood NonHVHZ-signed.pdf
manufacturers details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.3
1" 24ga. Gulf Snap
1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32"
Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/--131.OPS
Installation Instructions
F_1 _ R3 II FL11657 3 R3 Metal Roof Panel Detail -
si nq ed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Other: -67.3 psf @ 24" o.c. clip spacing. -131 psf @ 6" o.c.
clip spacing. Install per manufacturers details. For use in
Evaluation Reports
FL11651 R3 AE FL11651 3 R3 1 24GulfSnap 17 IS-
32P1 ood HVHZ-S! ngd.pdf
Created by Independent Third Party: Yes
HVHZ Zones.
11651.4
1" 24ga. VersaLoc
1" VersaLoc 24ga 16.5" Wide Roof Panel over 15/32"
Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Installation Instructions
FL11651 R3 II FLi1qq.1 4 R3 Metal Roof Panel Detail_
signed.pcif
Impact Resistant: N/A
Design Pressure: +N/A/-138.SPSF
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Other: -71 psf @ 24" o.c. clip spacing. -138.5 psf @ 6" o.c.
clip spacing. Install per manufacturers details. For use in
HVHZ Zones.
Evaluation Reports
FL11651 R3 AE FL11651 4 R3 24VersaLcc SR 1§.5 15-
32Plywood HVHZ-.siqugdt.pdf
Created by Independent Third Party: Yes
11651.5 1 1" VersaLoc .032" Aluminum
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-101.OPSF
1" VersaLoc min .032" Aluminum over 15/32" Plywood
Installation Instructions
ELS_1651_ R3I FL.11651 5__R3 _Metal 3oof Panel Detail_
si ned. d
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
p://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsk-1-r 2fTr... 4/16/2018
Florida Building Code Online
Page 3 of 5
Other: -63.3 psf @ 24" o.c. clip spacing. -'101.0 psf @ 6"
o.c. clip spacing. Install per manufacturers details. For use
in HVHZ Zones.
Evaluation Reports
0L11651 R3 AE FL11651 5 R3 Lin 032VersaLoc
SR 16 15-32PIy HVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.6
1.5" 24ga. Gulf Snap
1.5" Gulf Snap 24ga. 16" Wide Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL_11651 R3 II FLlj_W51 6 tal Roof Panel Detail -
signed.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-116.OPSF
Created by Independent Third Party: Yes
Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
Evaluation Reports
o.c. clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install
FL11651 R3 AE FL11651 6 R3 1_5 24GuIfSnap 16 15=
per manufacturers detals. For use in HVHZ Zones.
329iywood HVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.7 1 1.5" 24ga. Versal-oc
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-123.5PSF
Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. For use
in HVHZ Zones.
11651.8 12" 24ga. MegaLoc
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.SPSF
Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
o.c, clip spacing. Install per manufacturers details. Not for
use in HVHZ Zones.
1.5" VersaLoc min 24ga. 16" wide Roof Panel over 15/32"
Plywood
Installation Instructions
FL11651 R3 II FL11651 7 R3 Metal Roof Pane Det@il-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11657,_R3 AE FL11651 7 R3 1.5 2_4VersaLoc 16 1$=
32Plvwoad HVHZ-signed.pdf
Created by Independent Third Party: Yes
Min 24 Ga. 2" MegaLoc 18" wide Roof Panel over 15/32"
Plywood
installation Instructions
FL11651 R3 II Fl_11651 8 R3 Metal Roof Panel Detail-
signed_.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 8 R3 24Ve-M-4 c 18 15-
32PIy.wood NonHVHZ-signedpdf
Created by Independent Third Party: Yes
11651.9
24 Ga. Gulf Lok
Min 24 Ga. Gulf Lok 16" Wide over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL11651 R3 II FL11651 9 R3 Metal Roof Panel Detail -
sianed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-96.7PSF
Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76
psf @ 5-1/8" o.c. fastener spacing.-121.75 psf @ 5-1/8"
fastener spacing. -161 psf @ 5-1/8" fastener spacing. Install
per manufacturers details. Not for use in HVHZ Zones.
Evaluation Reports
FL11651_R3 AE_FL11651 9 R3 24GulfLok 16 15-
32Plywood NonHVHZ-signed,pdf
Created by Independent Third Party: Yes
11651.10 124 Ga. Gulf Seam
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-93.5PSF
Other: -93.5 psf @ 18" o.c. Install per manufacturers
details. Not for use in HVHZ Zones.
Min 24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood
Purlins over 15/32" Plywood
Installation Instructions
FL11651_R3 II FL11651 19 R3-Metal Roof Panel Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 10 R3 24GuIf5eam 16 ix4 15-
32Plywood Non HVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.11
24 Ga_. Gulf Seam
Min 24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof
Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL11651 R3 II FL11651 11 R3 Metal Roof Panel Detail -
signed.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-108.5PSF
Created by Independent Third Party: Yes
Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. Not for
Evaluation Reports
FL11651 R3 AE FL11651 11 R3 24GulfSeam 18 15-
32Plvwood Non HVHZ-sf
use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.12 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood
//www. flori dabuil ding. org/pr/pr_app_dtl . aspx?param=wGE VXQwtDgsQFc5K%2fTr... 4/16/2018
Building Code Online
Page 4 of 5
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-156.SPSF
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf
@ 6" o.c. fastener spacing. Install per manufacturers details.
For use in HVHZ Zones.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-131.PSF
Other: -94.25 psf @ 16" o.c. fastener pattern. -131.0 psf
@ 16" o.c. fastener pattern. Install per manufacturers
details. Not for use in HVHZ Zones.
installation Instructions
FLi1651 R3 II FLi16-j 12 R3 Metal Roof Panel Detail-
,
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 12 R3 265vCrimp 1S=
32Plywood HVHZlsigned,.pdf
Created by Independent Third Party: Yes
Installation Instructions
FL11651 R3 II FL11651 13 R3 Metal Roof Panel Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 13 R3 265vCrimp 15-
32Plkwood Nor�HVHZ=signed,pdf
Created by Independent Third Party: Yes
11651.14
26 Ga. 5V Crimp
Min 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over
15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Detail -Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-156.SPSF
Installation Instructions
FL11651 R3 II FL11651 14 R3 Metal Roof Panel -
s_gned.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf
@ 6" o.c. fastener spacing. Install per manufacturers details.
For use in HVHZ Zones.
Evaluation Reports
FL111 51 R3 AE FL11651 14_R3 265vCrimp lx4 15-
32Plywood NonHVHZ—signed_pdf
Created by Independent Third Party: Yes
11651.15
26 Ga. Gulf Lok
Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32"
Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-161.OPSF
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
psf @ 5 3/16" spacing. -161.0 psf @ 5 3/16" o.c. fastener
spacing. Install per manufacturers details. For use in HVHZ
Zones.
Installation Instructions
FLi_1651 R3_II_FL11651 15 R3 Metal Roof Panel Detail_
991ed_pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3_AE FL11651_15 R3 26GulfLok 16 15-
32Plywood HVHZ=signed.pdf
I Created by Independent Third Party: Yes
11651.16
26 Ga. Gulf Lok
Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32"
Plywood
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL11651 R3 II FL11651 16 R3 Metal Roof Panel Detail -
aigned.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-63.5PSF
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
psf @ 5 3/16" fastener spacing. -161 psf @ 5 3/16" fastener
spacing. Install per manufacturers details. Not for use in
HVHZ Zones.
Evaluation Reports
FL11651 R3 AE FL11651 16 R3 26GulfLok 16 15-
32PIywood NonHVHZ-sped pdf
Created by Independent Third Party: Yes
11651.17
26 Ga. GuIfPBR
Min 26 Ga. Gulf PBR Roof Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL11651 R3 II FL11651 17 R3 Metal Roof Pane_ Detail -
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-154.7PSF
qigned.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Other: -59.25 psf @ 24" o.c. fastener pattern.-154.75 psf
@ 12" o.c. fastener pattern. Install per manufacturer details.
Evaluation Reports
FL11651 R3 AE FI 11651 17 R3 26GuIfPBR 15
Not for use in HVHZ
32Plywood NonHVHZ-signed,pdf
Created by Independent Third Party: Yes
11651.18
26 Ga. GuIfPBR
Min 26 Ga. GulfPBR Roof Panel over 1x4 Wood Purlins over
15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Installation Instructions
FL11651 R3 II FL11651 18 R3 Metal Roof Panel Detail -
signed.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-151.7PSF
Created by Independent Third Party: Yes
Other: -100.5 psf @ 24" o.c. fastener spacing.-151.75 psf
@ 12" fastener spacing. Install per manufacturer's details.
Evaluation Reports
FL11651 R3 AE FLSZ651 18 R3 26GuIfPBR 1x4 15-
32Plywood HVHZlsigned.pdf
For use in HVHZ Zones
Created by Independent Third Party: Yes
//www.floridabuilding.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgsQFc5K%2f]Fr... 4/16/2018
Fl
Building Code Online
Page 5 of 5
i
11651.19 126 Ga. GuIfPBR
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-154.7PSF
Other: -60.5 psf @ 24" o.c. fastener spacing.-154.75 psf
@ 12" o.c. fastener spacing. Install per manufacturer's
details. For use in HVHZ Zones.
11651.20 126 Ga. GuIfPBR
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-151.7PSF
Other: -94.25 psf @ 24" o.c. fastener spacing.-151.75 psf
@ 12" fastener spacing. Install per manufacturer's details.
Not for use In HVHZ Zones
Go to Page =
Min 26 Ga. GuIfPBR over 15/32" Plywood
Installation Instructions
FL11651 R3 II_ FL11651 19 R3 Metal Roof Panel Detail-
signed:pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 19 R3 26GuIfPBR I
3vwood HVHZ=sig
2Plned—pdf
Created by Independent Third Party: Yes'
Min 26 Ga. GuIfPBR over 1x4 Wood Purlins over 15/32"
Plywood
Installation Instructions
FL11651 R3 II FL11651 20 R3 Metal Roof Panel Detail-
sianed:pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3_AE FL11651_20 R3 26GulfPBR 1x4 IS-
32Plywood NonHVHZ-signed,.pdf
Created by Independent Third Party: Yes
Back Ejjt
eJ b Page 1/ 2 a 6
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida ::Privacy statement:: Accessibility Statement:: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
Credit Card
Safe
f m
://www. floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2fr... 4/16/2018