Loading...
HomeMy WebLinkAboutMASTER PLAN SHEET SINGLE PAD_ 91VI I a, is r'repara Install the � - outdoors generator set, in lts protective enclosure, y where adequate cooling andyentllz�tlar..�_ atwa s ave;labl�-r-�:�- The cen ° The i - -­ ---=)•'onsider these fators: ,Q nsfaltatton of the strictly with i0C IFGC generator must ccomply, -- 38, and_NFPq 70 standards A 37, NFPA-64 NFPA - ° Install the unit where air Inlet and o will not become obstructed b outlet openings etc. !f Prevailing winds ,,III cause glass, snow, drifting, considar cause biounn. -- ° install the generator on high --- .., levels will not rise and end n ground where water not operate in or be sub g This unit should ° Allow sufficient roc lected to standing water. for maintenance and on all sides of the generator Installed in accordance cing. This unit must be national Gpd� Tor MInMI With any local, state, or structures. dEstences from other ° Clearance from the ends and must '93d fat 0.97 front ofthe generator bushestre s. Clearance frahis me shrubs, generator must be a ml rance from t back of the ��Isearanc@ at the fop should be !n (4S7 mm). m) front a minimum of . ft protections from the wall.Strerciure, overhang, or ° 00 NOT Install under wooden decks unless there is at least 6 tat �' structu above the generator. (�•52 m) °f res cisarance ° Install the unit where rain Sump run -Off, landscape Irrigatiogutter down spouts,roc€ P pump dtschar9e does not flood rinklers, or A the spray the enclosure, including any air inlet o outlet openings. A ° Install the unit where services m or obstructed. Includingwill not be affected Be or covered services such as electrical, underground, av air condffloninexc g, or Irrigation. Thfuel, phone, and warmly Coverage. could a�rect ° mere $h'on9 Prevailing direction, face the g winds blow from one the Prevailing windgenerator air inlet openings to ° Install the generator as close as supply to reduce the length ofPossible to the fuel THAT LAWS OR Col)eg MYpiping. REAMWBER DiSTANCe AND LOCAT10N, in the THE local codes regarding placernent or clearance, of lommend following these quid we face. The --• " "'w,'nsualled on a level sur- (,13 mm generator must be level within a 0.5 In all around. - The generator 'a-typicallyplaced o — - - -- compacted soil, crushed stone, or a ConcretePea gravel, Pad' Check local codes to see what required. if a concrete pad is required, Is cable codes should be followedQufred, all appli- d - Generators v ldellnes for Stationary.Air-0ooled Ggn$rators NFPA 37 is the Association's The National Fire Protection stationary standard for the Instal►atian Spacing ry combustion engines. Its requirements llm the a11(of an enclosed generator set from structure or welt of s.; m a NFPq 37, Section 4.1.E Engines, , Engines Located � es, and their wQa#herproef housings if � atdool�: that are installed outdoors shaft be located at least g i7.52 ►'n) from Provided from structuresroopenings in walls and at least 6 tat It separations having combustible waits. (1-52 m) conditions exist not b@ required A minimum where the fbIlowing • The adjacent wall of the structure has a fire resistance rating of at least one hour. 2• The weathe noncombustib @j roof enclosure Is constroew of demons materials and It has been notfrafed that a fire within the enclosure nctowill sunit combustible materials Outside the n" X,4 A — ExPlanato 4.9.4 (2) MeansOf ateriaf 2 e Criteria was to dte within the rrnlne the Worst case fire scenario generator and fo determine the t items outside the engine enclosure gnitability of The enclosure is eonshuof@d at various die bls rnaterlals, and the of non-c tlances. 'dependent testing results and conclusjonsomhe lab indicated that any fire within the inatailation Guidelines For 8D HzAlr-Cooled Generators generator enclosure would not nearby oor»h►fQf,�,�,._ _ pose personnel r-- "ue, ccures, With or without fire pons K;R;J�) 57 M11 Low JW. sT it IdAM— W£ 4 No ominoCK us a m erc fture 3- •-J::;•r�_2t Sote�yy�,i,,�earchlhsgtu%li�arking Based on this, �u testin Sec 4.1.4, the, th requirements of . listed above are dean staliation of the NFPA 37, back side of the ene ged to 18 in (457 mm9enerators (�)• Far ad g rater to a statlona ) from the the are equate malntan ry wall or building a above the generator should be te and lea cl m) with a minimum of 3 ft at least 5� 62 Of the enclosure, (0-91 m) at the front and ends bushes. This includes trees, shrubs clearance Vegetation not in contpifance , and exhaust peters could obstruct air flow, Jaddition, growth, fumes from fee generator See is -f _; _ could Inhibit plant within the owner's manual for d the installation details, drawlnr Autornatl0 start-up* Disconnect ufflity render unit Inoperable before work! power and Failure to do so will result In death or serious Ind g on unit. ry. (00019?) �phyxiallon- Runnln . Poisonous noxtde, a colorless, ines produce avoidedCarbon mono odorless wisar�suli death or serious injury, NOTE; If the (000103) start as soon e►enerator is not set to arFeF:j kancl utili as fee battery cables b nectedntf the at power supply is not turned off, the battery posts and cause .an a sparking can occur xplosion. 1n9tallaHo I Guldellnes For 80 Hz Atr-Cooled Generators C Site Selection and Me Preparation ° Locate the mount! ng - the frahsfer switch a d fuel assu close as possible f( ° Leave adequate room access araundpthe area forservice k(check local to ecode), and place keep rising water from reachlne_tr,e_ enough e_�h..---- -- and UnobstructedNspace that Will n airflow provide adequate ° 218cletahveesun't soairvents wo, grass, $now, won't become clogged exhaust fumes , or debris, Verify that eaves will not enter any building through windows,` verntHation fans, or other intakes (see ° Select the �•'�• air to tYpe of base, such impacted soil, gravel, or concrete, not limited or as required by local taws or codes. as desired local requirements before seleciicng• Verify Your Material Sufficient for Level ins ° Prepare a re installation rem) deep*nguler area approximately, , In (.127 longer (A) and approxtmat g and Wider (a) than iee� s In (152 mm) generator verify that foofprint of fee generator will be mounted 1s compacted, rfaee weer@ the and will not erode over time. A concreteerted Poured if desired or releveled, , , required. p2d can be Figs Compacted►Sol/ or 0rMt 1Pad �OTZ,' If a concrete pad Is r federal, state, or local codes, squired, follow all applicable 13 ` \ \ GENERATOR CO PAD THICKNESS ISOMETRIC VIEW PADDIMENSIONS: D ENSIONS: CONCRETE GENERATOR r� = I GENERATOR UNIT BY o SEPARATE SUBMITTAL 3 (SEE SCHEDULE FOR N MINIMUM WEIGHT REQUIRED) �- 54"LENGTH PLAN VIEW CONCRETE PAD ROAD MESH MASTERFIBER 3" MIN MAC100 �4" MIN GROUNDS :.•i:: :.w:ar, r--,ic.i;, 50" 54" GENERATOR TABLE: (ON -GRADE APPLICATIONS ONLY) AMERICAST frww®meh�5�y mrrt 'MADH INAMIDR "vi TeL 713-9714939FM m464C69 Emil: "e�IGdJ.a[.4tl� µ«eeeh.Aaded[Ol wha •aa HVHZ OR NON-HVHZ RISK EXPOSURE (EXP) RISK EXPOSURE (EXP) RISK EXPOSURE (EXP) COUNTY I C D II C D III, IV C D P. BEACH 150 MPH 30.44 Psf 36.94 Psf 170 MPH 39.09 Psf 47.44 Psf 180 MPH 43.83 Psf 53.19 Psf BROWARD 156 MPH 32.92 Psf 39.95 Psf 170 MPH 39.09 Psf 47.44 Psf 180 MPH 43.83 Psf 53.19 Psf MIAMI-DADE 165 MPH 136.83 Psf 44.69 Psf 175 MPH 41.43 Psf 50.28 Psf 186 MPH 46.80 Psf 56.80 Psf BRAND &MODEL CAPACITY WIDTH LENGTH HEIGHT WEIGHT ALLOWABLE PRESSURE COMMENTS Generac 005871 & 005883 10 KW 25.00" 48.00 " 29.00 " 387 Ibs 41.43 Psf EXP C 175 MPH & D 156 MPH Generac 005872 & 005894 14 KW 25.00 " 48.00 " 29.00 " 439 Ibs 47.44 Psf EXP C 186 MPH & D 156 MPH Generac 6459, 6461, 6462 16 KW 25.00 " 48.00 " 29.00 " 513 Ibs 47.44 Psf Generac 006721 16 KW 25.00 " 48.00 " 29.00 " 448 Ibs 47.44 Psf Generac 005873 & 005885 17 KW 25.00 " 48.00 " 29.00 " 455 Ibs 47.44 Psf Generac 005874 & 005886 17 KW 25.00 " 48.00 " 29.00 " 421 Ibs 47.44 Psf Generac 005875 & 005897 20 KW 25.00 " 48.00 " 29.00 " 451 Ibs 47.44 Psf Generac 006729 & 006730 20 KW 25.00 " 48.00 " 29.00 " 516 Ibs 47.44 Psf Generac 006551 & 006552 22 KW 25.00 " 48.00 " 29.00 " 526 Ibs 47.44 Psf Kohler 14RES & 20RES 14-20 KW 26.00 " 48.00 " 29.00 " 5001bs 47.44 Psf GE 40323GE & 40324GE 13 KW 35.00 " 39.40 " 39.00 " 540 Ibs 39.09 Psf EXP C 170 MPH & D 156 MPH GE 04038215KW 15 KW 33.00 " 48.00 " 30.50 " 484 Ibs 43.83 Psf EXP C 180 MPH & D 156 MPH GE 04037817KW 17 KW 33.00 " 48.00 " 30.50 " 484 Ibs 43.83 Psf GE 40330GE & 40331GE 20 KW 33.00 " 48.00 " 30.50 " 600 Ibs 43.83 Psf Briggs & Stratton 040243-0 10 KW 31.00 " 32.00 " 34.00 " 430 Ibs 43.83 Psf Briggs & Stratton 040302-2 12 KW 33.75 " 50.00 " 31.60 " 507 Ibs 41.43 Psf EXP C 175 MPH & D 156 MPH Briggs & Stratton 040303-1 15 KW 33.75 " 49.00" 31.60 " 562 Ibs 43.83 Psf EXP C 180 MPH & D 156 MPH Briggs & Stratton 040304-1 18 KW 33.75 " 49.00 " 31.60 " 568 Ibs 44.00 Psf Briggs & Stratton 040305-1 20 KW 33.75 " 49.00 " 31.60 " 570 Ibs 44.00 Psf Generac 7035, 7036, 7037 16 KW 25.00 " 48.00 " 29.00 " 406 Ibs 47.44 Psf EXP C 186 MPH & D 156 MPH Generac 007038 & 007039 20 KW 25.00 " 48.00 " 29.00 " 448 Ibs 47.44 Psf Generac 007042 & 7043 22 KW 25.00" 48.00 " 29.00 " 466 Ibs 1 47.44 Psf GENERATOR MOUNTING CONFIGURATION: GENERATOR ATTACHMENT BASE OR SIMPSON A24 ANGLE BRACE W/ (4) #10 SS 316 SELF -DRILLING SCREWS _ TO GENERATOR T_ r F F (SEE GENERATOR SPECS) THICK GALVANIZED _= GENERATOR WASHER& RUBBER H (SEE CONCRETE PAD VIBRATION PAD SCHEDULE FOR DIMENSIONS & WEIGHT � REQUIRED) 4" T� 32" WIDTH 54" LENGTH SIDE VIEW FRONT VIEW GENERATOR ANCHOR TO PAD SCHEDULE SUBSTRATE DESCRIPTION CONCRETE: (2)-3/8"0 TITEN HD (6000 PSI OR EQUIVALENT, MIN.) 2-3/4" FULL EMBED O CONCRETE, 3" MIN EDGE DISTANCE, 6" MIN. SPACING TO ANY ADJACENT ANCHOR. NOTES: 1. ANCHOR QUANTITY PER LONG SIDE 2. EMBEDMENT AND EDGE DISTANCE EXCLUDES FINISHES, IF APPLICABLE. 3. ENSURE MINIMUM EDGE DISTANCE AS NOTED IN ANCHOR SCHEDULE. 4. ENSURE MINIMUM SPACING TO ANY ADJACENT ANCHORS. 5. FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS TO INSTALL ANCHORS. GENERATOR ATTACHMENT BASE, VARIES WITH MODEL SEE GENERATOR SPECS %" SIMPSON TITEN HD, SEE ANCHOR SCHEDULE 2"X3"X3%" GALV. STEEL - WASHER RUBBER VIBRATION PAD - J CONCRETE PAD 6,000 PSI LIGHTWEIGHT CONCRETE PAD X CONCRETE MIX 6,000 PSI LIGHTWEIGHT MASTERFIBER MAC 100 CONCRETE MIX & ROAD MESH NOTES: FOAM CORE 1. Y DISTANCE DEPEND ON GENERATOR BASE LENGTH, NO LESS THAN 2". 2. X DISTANCE 3" FROM UNIT EDGE TO CLIP. 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN ANCHOR REQUIREMENTS FRANK L BE ARD , P.E. PE# 0046549 03,E0120 18 _ Off.CI�D, CERTI +V.E. APDEAR's eBOW_ _ -_ __ ORDON M. OI TTISTO, P.E. SHEET IS PART OF A DIGITALLY SIGNED FILE, SHALL REMAIN IN DIGITAL FORMAT, & PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED L _ AND SEALED. IF THERE IS NO WIND DESIGN REQUIREMENTS_ DIGITAL SIGNATURE ONSHEET I OR THIS SHEET DOES NOT CONTAIN AN ENGINEER'S ORIGINAL SIGNATURE & SEAL, ( BASED ON ASCE 7-10 & FLORIDA BUILDING CODE SIXTH EDITION (2017)) THIS SHEET IS A COPY DRAPT. AT -GRADE SIGN METHOD rrnn rV ULTIMATE DESIGN WIND SPEED Vult = 186 mph U p NOMINAL DESIGN WIND SPEED Vasd = 144 mph zo RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A mm ® W M M U i m U) O EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= g� lllH LL uJ H �y JYinV0.85 rv^, LL vi W ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND 1u1J E: (n ` V) LU GUST EFFECT FACTOR = 0.85 PRESSURE AT HEIGHT H qh = 77.56 Ib/ft2 lLJ O 2 Cw7 ce _ Z W W" vZ'a` 5 FORCE COEFFICIENT SCANNED Q Q < LULL w W LL Cf = 1.44 �11 n W WIND PRESSURE: BY u`xj DQ _wt7 O OZ m o�� }} P= qh G Cf = 56.80 Ib/ft2 (ASD) �6 LIICIE County 11, W O r4 W W v W f-) UJ %v @ Z GENERAL NOTES M W 6=W 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE % W w 0 SIXTH EDITION (2017). -- n 2. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A -4 CD JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. N O SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH M d THE APPLICABLE BUILDING CODE SHALL BE LESS THAN OR EQUALTO THE O Oz DESIGN PRESSURE'ASD" CAPACITY VALUES LISTED HEREIN FOR ANY J ASSEMBLY AS SHOWN. 3. DIMENSIONS AND WEIGHT OF UNITS SHALL CONFORM TO SPECIFICATIONS ILI (/� Q 0 W Y STATED HEREIN. 4, UNITS MUST BE CENTERED ON PAD WITH OPPOSITE SIDES HAVING EQUAL • :j Ln Q C1 01 N CLEARANCE. A MINIMUM DISTANCE FROM UNIT TO PAD EDGE IS SPECIFIED. 5. CALCULATIONS MADE USING LIGHTWEIGHT CONCRETE 125 PCF LLI U d M 6. THE AREA UNDER CONCERETE SLAB ON GROUND SHALL HAVE ALL VEGETATION, STUMPS, ROOTS, AND FOREIGN ri I-i 2: W n C DzI W W O0 = LU n U) MATERIALS REMOVED PRIOR _J 8 TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS. 7. RESISTANCE TO SLIDING OF THE PAD ON THE GROUND IS NOT d N W n p z PART OF THIS DOCUMENT AS SOIL CHARACTERISTICS AND PAD PLACEMENT d Z It g 0OLL VARIES. C' L p 8 8. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY M Y . OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) a Ln W SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE .r^j N m EXPRESS RESPONSIBILITY OF THE CONTRACTOR. p 9. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES O INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL u FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT 1U r` m o z WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. P 10. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL CI RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS CI = LL in in RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE LL 13 PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY t) LL z " Z O O 0 WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING g CONTRACTOR. THE OF THIS p 5 3 g 11. ROLE ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE u� o INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BY c P BE COORDINATED THE PERMITTING CONTRACTOR. o F o 12. THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN TO ANY SPECIFIC PROJECT SITE. INFORMATION CONTAINED HEREIN IS BASED ON W Y w w a Tu z z CONTRACTOR -SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS k SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS 12 wo DVD A o gq OR INACCURATE DATA OR MEASUREMENTS. DIMENSIONS ARE SHOWN TO aa U, z - ' ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. COPYRIGHT ENGINEERING EXPRESS® WORK SHALL BE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO 17-3961.1 REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS SCALE: NTS UNLESS NOTED AND FABRICATION AND INSTALLATION OF MATERIALS. ALTERATIONS OR OF ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. 13. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED.