HomeMy WebLinkAboutSOIL NUCLEAR GAUGESoil
=rdamn�
Nuclear Gauge
Client:
Project:
- --- -
- -
- -
-
-
&'/As.SOClates, InC.:
_e _
Pe mit`# 1809-0122
_ _
Renar Deve nt Corp.
113=15 66=54346
G O� OJ�
�
Report Date: 215/2019.'
3725 S. fast Ocean. Boulevard, Suite 101
Momingside Residential Lots
o �0, '
Port SL Lucie Branch
Test'Method: ASTM D 6938
Stuart, FL 34996'
Fort Pierce
�o1�
Florida CA No. 5950
460 NW Concourse Place, Unil 1.
......
....... ...... ...
Fort Pierce, FL . .
..
10.
..
- . Port SL Lucie; FL 34986 ..
. .
" Phone:772-878-.0072
.. ....
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method `
Soil
Classification
Optimum
Moisture
(%) '
Maximum
Dry Density"
(pcf) "
In Place
. Moisture
(%)
In Place
Dry Density
(pcfj
Probe
Depth,
(in) '
Percent
Compaction
Min Comp.,
°k)
Remark
103 .
:
2/5H9
18-194
.. A
11.5
112.5
9.8
111.6
12
: 99
; ' 98
.. Pass ..
104 :
2/5/19
18-194
A
—
: 11-.5
112:5
10:0
110:4
12
" " 98
" 98
Pass
105
.2/5M9
.18-194
A,
—
11.5
112:5
9.2
110:9
12
99
'98
Pass .:
106
2/5/19
-18-194
A..
.....
11.5
.112:5
8.9
111:1
12
99
98
Pass
107
215/19 -
- : 18-194
A
—
11.5.
112.5.
11.1
110.6
12
98
98
:Pass
`' ...
Test
Information ' :... .
Test #
Test Location
Elevation
-
Reference
Gauge
Make / Model / SN / Calibrated
Field Technician "
103
Foundation: Foundation'for House Lot 68 at 68 Starboard Drive
SE Comer. - .
-1.0
Top of Pad
CPN [MC-3 / M330907151 !
Tech, Port St. Lucie
104 :
Foundation: Foundation for House Lot 68 at 68 Starboard Drive
NE Comer
-1.0.
Top of Pad
CPN I MC-3 ! M330907151 /
Tech, Port St: Lucie
105
Foundation: Foundation for House Lot 68 at 68 Starboard Drive
NW Comer.' .
-1.0
Top of Pad
CPN /,MC-3 / M330907151 /
Tech, Port St. Lucie
106
Foundation: Foundation for House Lot 68 at 68 Starboard Drive :
SW Comer _..
A.0
Top of Pad
_ . .
CPN MCA./ M330907151 !
Tech, Port St. Lucie:
107
Foundation: Foundation for House Lot 68 at 68 Starboard Drive
Center,
-1.0
Top of Pad
o
CPN / MC-3 1 M330907151 !
Tech, Port SL Lucie
Remarks ...
Comments.. -
Pass_ : Density Pass
Tests are .'Direct Transmission• (Method A) unless probe'depth is noted as
'Backsratter". Gauge calibration data on file with the testing agency.
AS A MUTUAL PROTECTION TO OUR.CLIENT, THE -PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY QF .:: Page 1 of
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR. EXTRACTS FROM OUR REPOb2TS IS RESE.nVED h\ , ` ' '
•
PENDING OUR WRITTEN APPROVAL.