BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescri tive and Performance Method
p
RECEIVED
APR '0 5 2019
Permitting Department
St. Lucie County
��Af�IlalE®
Permit #: l ROCI - o I,a 4 Y ounty
ractor: R ehA-R lia" i 10 —AS
lddress: 61-Ql RA-,M 1,2660 C _�
ction: (>Q New Construction — Complete ( ) Existing —After Addition
�e Infiltration Test Results SLC Climate Zone 2
(50) = lCIS Test Date:
me =
(50) = CFM (50) x 60 / Volume = . C) Mechanical Ventilation required less than 3 ACH
ng results must be & ACH (SO) or less 0 Pass ( ) Fail
The ' uilding or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding? air changes per
houi in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Sect on 553.993(5) or (1), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
i
app wed third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
they; al envelope.
Whe'le the air infiltration rate of a dwelling unit is less than 3 air changes,per hour when tested with a blower door at a
pres ure of 0.2 inch w. c. (50 Pa) in accordance with Section 11402:4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Company Name: Florlda Fna= Testing Address: I Od6 5 ty. PA-uti.= A& as/_ -3 �l�f
req
Pri
Lice
certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
tents in accordance with Section R402.4.1.2 Climate Zone 2.
Name: RUS,S21 I fs-- I 1Q4G )g A-