HomeMy WebLinkAboutSOIL NUCLEAR GAUGE:-
' ...
. Soil. Nuclear. Gauge:.: ClProject•:....
_ ::.�►rdam��:n
lent•
&' Asstaclates; inc:,
Report�Date: 10/30/2018 Renar Development Corp.:: :1.13-15-1i6=54346
Test Method: ASTM D 6938 3725 S. East Ocean' Boulevard; Suite 101 Momii igside Residential Lots
Pon si Le�ie Branch Stuart,; FL 34996' :: Fort: Pierce
Florida CA No. 5950 .... :. , • Fort; Pierce F
460 NW Concourse Place, Unit 1
Port St. Lucie, FL 34986 '
Phone:772-878-0072 - I
A561
�—
�ILE
COPY
'Test Results:
Test #
Retest
Of
Test
:. Date
Proctor ID _ ::
Method.
Soil
Classification
Optimum
Moisture
e )
( /a .: ; .
Maximum
Dry Density:
(pcf) :.
In Place
Moisture
(% ) :.
'In:Place :
Dry Density
(pcf) -
Probe
Depth_
(In)
Percent
Compaction
Min Comp.
o )
(/o
Remark
47
10/25/18
18-193
A
--
12.0
115.5
6.5
113.8
12 :
99
95
Pass
48
10/25/18
: 18-193 :
A
--
12.0:
: 115.$ .
6:9
11$:1 :
12
100 .
95
: Pass.
.49
...
10/25/18..
'18-193.
A...
--.
12.0
115.5,
.4.7
114.2
12
99
95.. ..
Pass
50
10/25/18
18-193
A
--
..12.0
.. 115.5
6.3
113.4
12
98
95
Pass
51
10/25/18 :
18--193
A
=-
12:0
: 115.5
4.0
116.2
12
101
95
:Pass
Test
Information
Test #
Test Location p
Elevation
Reference
Gauge .
Make /Model / SN /Calibrated
Field Technician
47
Building -'Slab on Grade: Permit# 1809-0125. Southeast Comer'of House Pad at 45
Seaspray Drive
-1.0
Top of House Pad
. Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
48
Building - Slab on Grade: Permit# 1809-0125. Southwest Comer of House Pad, at 45
Seaspray Drive ....
:-1.0
Top of House Pad:
Troxler /-T-3430 121330 /
Tech, Port St. Lucie
49
Building -Slab. on Grade: Permit# 1809-0125. Center of House Pad at 45 Seaspray
Drive
4.0 . -
Top of. House Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie :.
50
Building - Slab:on Grade: Permit# 1809-0125. Northwest Comer of House Pad at 45
seaspray Drive
-1.0
Top of House Pad
Troxler / T-3430 / 21330 /
Tech,' Port_ St. Lucie:. "
51
Building - Slab on Grade: Permit#1809-0125. Northeast Comer of. House Pad at 45
Seaspray Drive
-1.0
Top of House Pad
Troxler) T-3430 / 213301
Tech, Port St. Lucie
Remarks: ::
•....... ._.... Comments: .
..
.....
Pass:: Density Pass
Tests are "Direct -Transmission" (Method A) unless probe depth; is noted as :
"Backscatter". Gauge.calibration data on file with the.testing agency.. ...
:.
r /
Pe
S U 9 Oepa
c� ��� ty enr:
A-MUTUAL=P-RE)TEC—TI6W—T"UF;F-CEIEN3 fHE PtJBtiC=A1VD OURSELVES; ALTREPO tTS ARE SUB(1AITTED AS TFiE.CONFIDENTIAL PROPERTY OF Paige.1 of 1
THE: CLIENT, ANDAUTHORIZATION. FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS' FROM OUR REPORTS IS RESERVED