HomeMy WebLinkAboutPRODUCT APPROVAL - METAL ROOFINGBuilding Code Online
Page 1 of 3
60W or
i�
'Pr0 0 '•g o
BCIS Home Log In I User Registration I Hot Topics I Submit Surcharge Stats & Facts Publi tions ,j Contact Us BCIS Site Map Links Search
e
Product Approva��
PUSER: Public User LE Cr
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
CONCEALED FASTENERS OR AI ACHMENTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OR RECORD
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
FL20484-RI
Revision
2017
Approved
UNION CORRUGATING COMPANY
701 S. KING ST.
FAYETTEVILLE, NC 28301
(910) 483-0479 Ext 256
jstieby@unioncorrugating.com
John Stieby
jstieby@unioncorrugating.com
RECEIVED
SEP 072018
ST. Lucie County, Permitting
SCANNED
By
St Lucie County
TLI
WORK
-CORRECTIONS
PRSrlN A C OA
ARY IN ORDER TO
Roofing �11 I1 � LLAPP (CABLE ODES.
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Bala Sockalingam
PE-62240
Keystone Certifications, Inc.
09/07/2027
Yoosef Lavi, P.E.
R Validation Checklist - Hardcopy Received
Certificate of Independence FL20484 RI COI CertificateIndeoendence.odf
Referenced Standard and Year (of Standard) Standard Year
FM 4470 2012
TAS 125 2003
UL 1897 2012
UL 580 Q y� ri•� 2006
Equivalence of Product Standards �L.�"A.A
Certified By
ST. LUCIE COUNTY BUILDING D SSIG N
Sections from the Code REVIEWED FOR CQMPLIANCE„/��yA7
PLANS AND PEA2MV MUST BE K T JOB
SITE OR NO INSPECTION(S) V LL DE MADE
>://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJg... 9/3/2018
Building Code Online
r�
i
Page 2 of 3
Product Approval Method Method 1 Option D
Date Submitted 08/23/2017
Date Validated 08/28/2017
Date Pending FBC Approval 09/01/2017
Date Approved 12/12/2017
FL # Model, Number or Name
20484.1 5V
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-169
Other: Uplift load of 71.0 psf @ fastener spacing of 24" o.c.
& 169.0 psf @ fastener spacing of 6" o.c.
Description
Min 26 ga., 24" wide through fastened panel over 15/32"
thick plywood
Installation Instructions
FL20484 R1 II EvaluationReportC2175 I.Pdf
Verified By: Bala Sockalingam, P.E. 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL20484 R1 AE EvaluationReportC2175 i.odf
Created by Independent Third Party: Yes
20484.2
Advantage-Lok II
Min 26 ga., 16" wide concealed fastened panel over 7/16"
thick OSB & 15/32" & thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II Evaluation Rei)ortC2 175 2.1)df
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-116
Evaluation Reports
Other: Maximum uplift load of 116.0 psf @ seam fastener
FL20484 R1 AE Eva IuationRepo rtC2175 2.odf
spacing of 4-5/8" o.c. along seam into min. 15/32" thick APA
Created by Independent Third Party: Yes
rated plywood with retainer strap.
20484.3
Aluminum Advantage-Lok II
Max 16.375" wide, nom 0.032" thick (min.) aluminum
concealed fastener roof panel over min 15/32" thick plywood
deck or 7/16" thick OSB.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II Eva luationReportC2175 3.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-93.5
Evaluation Reports
Other: Uplift load of 22.5 psf at fastener spacing of 18.5"
FL20484 RI AE EvaluationReoortC2175 3.pdf
o.c. and 86.0 psf at fastener spacing of 4.63" o.c. in 15/32"
Created by Independent Third Party: Yes
plywood or 7/16" OSB. Uplift load of 93.5 psf at fastener
spacing of 4.63" o.c. with structural sealant in 15/32"
plywood.
20484.4
Aluminum SL150
Max 16" wide, nom 0.032" thick (min.) aluminum snap -lock
standing seam metal panel over min 15/32" thick plywood
deck or 7/16" thick OSB
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL20484 R1 II EvaluationReportC2175 4.1)df
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-86
Other: Uplift load of 45.0 psf at clip spacing of 24" o.c. and
Evaluation Reports
FL20484 RI AE EvaluationReportC2175 4.pdf
78.5 psf at clip spacing of 6" o.c. in 15/32" plywood or 7/16"
Created by Independent Third Party: Yes
OSB. Uplift load of 86.0 psf at clip spacing of 6" o.c. with
structural sealant in 15/32" plywood.
20484.5
MasterRib
Min 29 ga., 36" wide through fastened panel over 15/32"
thick plywood or 7/16" thick OSB
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II Eva luationReportC2175 5.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-124
Evaluation Reports
Other: Uplift load of 56.0 psf @ fastener spacing of 24" o.c.
FL20484 R1 AE EvaluationReportC2175 5.1)df
& 124.0 psf @ fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
20484.E i MasterRib
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-88.5
Other: Uplift load of 56 psf for Fastening System 1. Uplift
load of 88.5 psf for Fastening System 2.
Min 29 ga., 36" wide through fastened panel over 15/32"
thick plywood
Installation Instructions
FL20484 RI II EvaluationReportC2175 6.pdf
Verified By: Bala Sockalingam, P.E. 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL20484 RI AE EvaluationReportC2175 6.odf
Created by Independent Third Party: Yes
s://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJg... 9/3/2018
Building Code Online _
Page 3 of 3
20484.7
ML150
Max 16.5" wide, min 24 ga. steel standing seam panel over
15/32" thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 RI II EvaluatiollReoortC2175 7.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-124
Evaluation Reports
Other: Maximum uplift load of 124 psf @ clip spacing of 6"
FL20484 RS AE EvaluationReportC2175.7.pdf
o.c. with 180 seam, self -adhering membrane and fixed clip.
Created by Independent Third Party: Yes
20484.8
PBR or R Panel
Min 26 ga., 36" wide through fastened panel over 15/32"
thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II Eva luationReportC2175 8.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-161.5
Evaluation Reports
Other: Uplift load of 30.0 psf at fastener spacing of 48" o.c.
FL20484 R1 AE EvaluationReDOrtC2175 8.pdf
and 161.5 psf at fastener spacing of 6" D.C.
Created by Independent Third Party: Yes
20484.9
SL175
Max 18" wide, min 24 ga., snap -lock standing seam metal
panel over 15/32" thick plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R1 II EvaluationReDOrtC2175 9.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-93.5
Evaluation Reports
Other: Uplift load of 39.8 psf @ clip spacing of 36" o.c. and
FL20484 R1 AE Evaluation ReoortC2175 9.pdf
78.6 psf @ clip spacing of 8" o.c with felt. Uplift load of 93.5
Created by Independent Third Party: Yes
psf @ clip spacing of 12" o.c. with self -adhering membrane.
Back Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the offlce by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
click here .
Product Approval Accepts:
® ® ® eChtc4:
Credit Card
Safe