Loading...
HomeMy WebLinkAboutEVALUATION REPORTEXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 T"-rm 353 Christian Street IA�y ERD Oxford, CT.06478 (203) 262-9245 :VALUATION REPORT ` 1t Lucie rRl-BUILT Materials Group, LLC Evaluation ReportA42970.10.12-R2 'O Box 70 FL16027-R2 tutherford, NJ 07070 Date of Issuance:l0/23/2012 800) 516-1485 Revision 2: 09/15/2017 his Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of instruction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, .E. for use of the product .under the Florida Building Code. The product described herein has been evaluated for :)mpliance with the 6th Edition (2017) Florida Building Code sections noted herein. : TRI=BUILT Modified Bitumen Roof Systems : Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. . ADVERTISEMENT: The Evaluation Report number preceded by the words `Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official.. This Evaluation Report consists of pages 1 through 4, plus a 26-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 09/25/2017, This does not serve as anelectmnically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC: d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 1 TRINITY 1 ERD ) NG SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: TRI-BUILT Modified Bitumen Roof Systems, as produced by TRI-BUILT Materials Group, LLC, have demonstrated compliance with the following sections of the 1 th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2011 1504.7 Impact FM 4470 2012 1507,11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 3. REFERENCES: gniitl ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1861) Examination Physical Properties FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 Physical Properties FM 4470/4474 Physical Properties FM 4470/4474 Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470/4474 FM 4470/4474 FIVI 4470/4474 .Reference 1)10490.10.08-2 P13760.09:09 P13770.09.09 P30540.11.09-111 P30550.12.09 033960.12.10` P33970.03.11 P37590.03.13-3A P39680.03.1.3 P37590.03.13-1-R1 P37590.03.13-2-111 P37590.07.13-2 P37590.09.13-5-R1 P37590.07.13-1 P45940.09.13 P44970.10.13 2W7A7.AM OD3A3.AM 2DOAO.AM 2D5A9.AM 3006646 3001334 3001334 3000857 3004091 3006115 3012321 3014692 3014751 3007170 3019317 3020103 3018332 3023868 3024594 Date 10/30/2008 09/10/2009 09/10/2009 11/30/2009 12/02/2009 12/30/2010 03/15/2011 03/06/2013 03/04/2013 06/26/2013 07/01/2013 07/01/2013 07/01/2013 07/02/2013 09/04/2013 10/04/2013 08/04/1994 04/04/1957 12/23/1998 06/22/1999 01/04/2000 01/25/2000 02/15/2000 01/12/2000 01/12/2000 05/02/2001 07/29/2002 08/08/2003 08/27/2003 01/13/2004 06/30/2004 07/30/2004 01/31/2006 03/20/2006 05/23/2006 Exterlor Research and Design, LLC. Evaluation Report A42970.10.12-R2 Certificate ofAuthorization #9503 6TM EDITION (2017) FBC NON-HVH2 EVALUATION FL16027-112 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Revision 2: 09/25/2017 Page 2 of 4 � TRINIIYJERD EntitV Examination Reference Date FM Approvals(TST1867) FM 4470/4474 3023458 07/18/2006 FM Approvals(TST1867) FM 4470/4474 3030668 09/12/2007 FM Approvals(TST1867) FM 4470/4474 3032172 06/12/2009 PRI (TST5878) Physical Properties PUSA-062-02-01 12/.04/2007 PRI (TST5878) Physical Properties. PUSA-061-02-02 01/28/2008 PRI (TSTS878) Physical Properties PUSA-064-02-02 02/27/2008 PRI (TST5878) Physical Properties PUSA-062-02-02 12/04/2008 Miami -Dade (CER1592) HVHZ Compliance Various NOAs Various Miami -Dade (CER1592) Proposal for Review 10-0823 10/12/2010 UL LLC (QUA9625) Quality Control MI -Agreement 02/27/2012 UL LLC (QUA9625) Quality Control ML Correlation, R27202 08/20/2012 UL LLC (QUA9625) Quality Control Service Confirmation, R14571 Exp. 10/06/2018 4. PRODucr DESCRIPTION: This Evaluation Report covers TRI-BUILT Modified Bitumen Roof Systems installed in accordance with TRI-BUILT Materials Group, LLC published installation instructions and the Limitations / Conditions of Use herein.. The following membranes make up the subject systems. Table 1 Roll Goods for TRI-BUILT Modified`Bitulnen Roof Systems . Type Product Specification Reference Grade Type SBS Membranes, TriBuilt SA SBS Base ASTM D6163, Table 2 S I TriBuilt SBS Granular ASTM D6164 G 1 TriBuilt SA SBS Cap ASTM D6164 G I APP Membranes TriBuilt APP Smooth ASTM D6222 S I I TriBuilt APP Granular ASTM D6222 G I TriBuilt SA APP Cap ASTM D6222 G I S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity{ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Refer to a. current Approved Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance.with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 1.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. Exterior Research and Design, I.I.C. Evaluation Report A42970.10.12-R2 Certificate ofAuthorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL16027-R2 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Revision 2: 09/25/2017 Page 3 of 4 1 `•. TRINITY 1 ERD 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation,the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing. Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 121, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. 6. INSTALLATION: 6.1 TRI-BUILT Modified Bitumen Roof Systems shall be installed in accordance with. TRI-BUILT Materials Group, LLC published installation instructions, subject to the Limitations / Conditions of Use noted below. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY:. UL LLC— QUA9625; (314) 578-3406, k.chancellor@us:ul.com - THE 26-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT Exterior Research and Design, I.I.C. Evaluation Report A42970.10.12-R2 Certificate of Authorization#9503 6T"EDITION (2017) FBC NON-HVHZEVALUATION FL16027-112 TRI-BUILT Modified Bitumen Roof Systems, (800) 516-1485 Revision 2: 09/25/2017 Page 4 of 4 n/0 TRINITY I ERD L •APPENDIX;I: ATTACHMENT RECtUIREMENTS FOR;WIND UPLIFT.RESISTANCE .. Table Deck Application Type Description. Page SA-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4 1A-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5 1B Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 5 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 6 1D Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 6 1E-1 Wood New or Reroof (Tear --Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 7 3E-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 8 ---.u___Newor.-Reroof(Tear_Off),_ - _ F_ 4 Non-insulated,,eonded Roof Cover_- S ', 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 9 _ 2B Steel or structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 9 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached. Base Sheet, Bonded Roof Cover 10 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 11-14 3B Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 14 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 15-16 46 LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, BondedInsulation, Bonded Roof Cover 16 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 17-19 SA CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 20 5B CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 21 5C CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 22 SD CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 22 5E CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 22 6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 23 6B Gypsum New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 24 6C Gypsum New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 24 6D Gypsum New Reroof (Tear -Off) or Recover E Non -Insulated .Mech. Attached Base Sheet Bonded Roof Cover 24 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 25-26 78 Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 26 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-Inch penetration. y Steel: Minimum 0.75-Inch penetration and engage the top flute of the steel deck. ➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation Instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocya nu rate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the QA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when Installed with the roof cover. Exterior Research and Design, I.I.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization k9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 1 of 26 0 "I�TRINI-ry ERD 4. Minimum 200 psi, minimum 2-inch thick lightweight Insulating concrete may be substituted for rigid Insulation board for System Type D (mechanically attached base sheet, bonded roof'cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. S. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016). 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturers published Instructions.. ➢ HA (HA): Full coverage at 25-30 Ibs/square. ➢ Dow1NSTA STIK QuikSet Insulation Adhesive (D45): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-Inch wide ribbons,12-inch o.c. ➢ OMG OlyBond S00 (OB500): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ ICP Adhesive & Sealants CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c. ➢ Note: When mult/ple layers(s) of insulation and/or coverboard are Installed In ribbon -applied adhesive, adhesive ribbons shall be staggered from layer-to-loyer a distance of one-half the ribbon spacing. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the Insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'Increase' the MDP listings In the tables; rather if MOP listing below meets or exceeds that listed for a particular system In the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick) ➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-Inch thick Multi -Max FA-3) ➢ OMG OlyBond 500 (OB500): MOP -187.5 psf (Min_ 0.5-Inch thick ISO 95+ GL) ➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-Inch thick ENRGY 3) ➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam 11) ICP Adhesive & Sealants CR-20: MDP-117.5psf (Min. 1.0-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded Insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 10, For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard'TAS 105., 12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (forrecover) shall be capable of resisting project design pressures on Its own merit to the satisfaction of the Authority Having. Jurisdiction, as documented through field uplift testing In accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. 14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with, FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. Exterior Research and Design, I.I.C. d/b/a Trinity ( ERD Evaluation Report A42970.10.12-R2 for F1.16027-112 Certificate of Authorization If9503 67" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 2 of 26 `J TRINITY I ERD 15. Unless otherwise noted, refer to the following references for bonded base; ply or cap sheet applications. , ;, . • , . .. : •' . ` ' -, � ... 'TABLE 1tTRI-BUILTROOF COVeRs Reference Layer Material Application BP -AA Base Ply FBC Approved ASTM D4601, Type II (Base and Ply sheets, Asphalt -Applied) HA at 20-40 Ibs/square Ply FBC Approved ASTM D2178, Type IV or VI SBS-AA Cap Ply TriBuilt SBS Granular HA at 20-40 Ibs/square (5 BS,. Asphalt -Applied ). SBS-TA Cap Ply TriBuilt SBS Granular Torch -Applied (SBS, Torch -Applied) SBS-SA Base Ply TriBuilt SA SBS Base (SBS, Self -Adhering) Self -Adhering Cap Ply TriBuilt SA SBS Cap APP-TA Base Ply or Ply TrlBuilt APP Smooth (APP, Torch -Applied) Torch Applied Cap Ply TriBuilt APP Smooth, TriBuilt APP Granular APP-SA Cap Ply TriBuilt SA APP Cap Self -Adhering (APP, Self -Adhering) 16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations, The lesser of the'MDP listings below vs. those in Table 3A applies: VAPORBARRIER•OPTIONS,STRUCfURALCONCRETEDECI(;ADHEREOINSULATfON.PERTABLE3A;, ' Option k Primer Vapor Barrier Insulation Adhesive MDP (psq Type Attach VB-1. ASTM D41 TriBuilt SA SBS Base Self -Adhering Inta-Stik or CR-20,12-inch o.c. -60.0 VB-2. ASTM D41 TriBullt SA SBS Cap Self -Adhering Insta-Stik,12-inch o.c. -75.0 VB-3. ASTM D41 TriBUllt SA SBS Cap Self -Adhering. Millennium One Step Foamable Adhesive, 12-inch o.c. -157.5 VB-4. ASTM D41 TriBUilt SA SBS Cap Self -Adhering CR-20, 1271nch o.c. -270.0 V6-5. ASTM D41 TriBuilt SA SBS Base Self -Adhering Millennium One Step FoamableAdhesive, Mlllennlum PG-1 Pump Grade Adhesive, OlyBond 500 or CR-20,12-Inch o.c. -290.0 17. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements. 18. "MDP Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, LLC. d/b/a Trinity (ERD Evaluation Report A42970.10:12-R2 r FLf60Z9- Certificate of Authorization 09503 0' EDITION (1017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by; Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 3 of 26 TRINITY I ERD ti TABLE 1A-1:'WOOD DECKS -NEW CONSTRUCTION;oR REROOF (TEAR OeF) . SYSTEMTYRE A 21•;MECHANIGALLY LITTACHED ANCHOR SHEET, BOM1IDED INSULATION, BONDED'ROOF COVER, System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 1S) MDP No. (Note i) Type Fasteners Attach Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Min.0.25-inch Dens Polyglass G2 Base, 8-Inch o.c. in 4- Deck, Dens Deck Prime, 32 ga., 1-5/8- inch lap and 8- (Optional).FBC SECUROCK Gypsum - Min.19/32- CertainTeed Glasbase, inch diameter inch o.c, in Approved, Fiber Roof Board, Min. SBS-AA, W-1 inch plywood Firestone ME, Base, JM tin caps with 11 three, equally ASTM C1289, HA 0.75-inch FescoBoard HA BP -AA (Optional) SBS-TA, -60.0 at Max. 24- Perma-Ply 28, Tamko annular ringspaced, P a II of iso- type P Y (homogeneous) o� min. ( g ) BP AA APP-TA inch spans Glass Base or shank nails shank staggered cyanurate 0.5-Inch Structodek GAFGLAS #75 center rows High Density Fiberboard Roof Insulation Polyglass G2 Base, 8-inch o.c.In 4- MIn.19/32- CertalnTeed Glasbase, 32 ga., 1-5/8- inch lap and 8- (Optional) FBC Min. 0.25-inch Dens (Optional) SBS-SA, inch plywood Firestone MB Base, JM Inch diameter inch o.c. in Approved, Deck, -Dens Deck Prime, One or APP-SA, W-2 at max. 24- Perma-Ply 28, Tamko tin caps with 11 three, equally ASTM C1Z89, HA SECUROCK Gypsum- SBS-SA more 565- SBS-TA or 60.0 inch spans Glass Base or ga. annular ring spaced, type II polyis0- Fiber Roof Board SA or APP TA GAFGLAS #75 shank Halls staggered cyanurate APHA P-TA center rows 6-Inch c.c. in 4- Min. 2-inch D-IS, 09500, Min.19/32- 32 ga., 1-5/8- Inch lap and 6 ACFoam II, III, CR-20 or M- Min. 0.25-inch Dens D-IS, inch plywood Polyglass Elastobase Inch diameter Inch o.c. in H-Shield, H- OSFA, atop Deck, Dens Deck Prime OB500, (Optional) SBS-AA, W-3 at max. 24- or Polyglass tin caps with 12 four, equally Shield CG, fastener or SECUROCK Gypsum- CR-20 or BP -AA BP -AA SBS-TA, -60.0 * Inch spans Elastobase Poly ga. annular ring spaced, Multi -Max FA3 rows, 7-inch Fiber Roof Board M-OSFA APP TA shank nails staggered or.ENRGY-3 cc center "rows 6-inch o.c. in 4—Min. 2-inch D-IS, OB500, Min. 19/32- 32 ga., 1-5/8- inch lap and 6- ACFoam II, III, CR-20 or M- D-15, (Optional) SBS-SA, inch plywood Polyglass Elastobase Inch diameter Inch o.c. in H-Shield, N- OSFA, atop (Optional) Additional OB500, One or APP-SA, W-4 at max. 24- or Polyglass tin caps with 12 four, equally Shield CG, fastener layers of base insulation CR-ZO or SBS-SA more SBS- SBS-TA or -60.0* inchspans Elastobase Poly ga. annular ring spaced, Multi -Max FA3 rows, 7-Inch M-05FA SA or APP TA shank nails staggered or ENRGY-3 cc APP-TA center rows Exterior Research and Design, LLC. d/b/a Trinity( ERD Evaluation Report A42.970.10.12-R2 or FL16027-RZ Certificate of Authorization 99503 6n' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared. by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) S16-148S Appendix 1, Page 4 of 26 QTRINITYI ERD TABLtIA 2 WOOD DECKS NEW CONSTRUCTION, REROOF;(Teaa OFF) oR RECOVER - SYSTEM.TYP.E'A-2:"MECHANICALLYQTTACHEDANCHdRSHEET,:BONDEDIN5LILATION;BONDEDROOFCOVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP Type Fasteners Attach Type Attach Type Attach Base Ply Ply Cap Ply No. (Note 1) (Psf) 12-inch o.c. in 4- Min. 0.25-inch Dens Deck, Min.19/32- Polyglass OMG Flat Inch lap and 12- (Optional) FBC Dens Deck Prime, SECUROCK Inch plywood Elastobase or Bottom Plates inch o.c. in two, Approved, Gypsum -Fiber Roof Board, (Optional) SBS-AA, SBS- W-5 at inax. 24- Polyglass (square) with equally spaced, ASTM C1284, HA Min. 0.75-inch FescoBoard HA BP -AA BP -AA TA, APR -TA -60.0 inch spans Elastobase Roofgrip #12 staggered center type 11 polyiso- (homogeneous) or min. 0.5- Poly cyanurate inch Structodek High Density rows Fiberboard Roof Insulation Polyglass 12-inch o.c. in 4- (Optional) FBC (Optional) Min.19/32- Elastobase or OMG Flat inch lap and 12- Approved, Min. 0.25-inch Dens Deck, One or SBS-SA, APP- W-6 inch plywood Polyglass Bottom Plates Inch o.c. in two, ASTM C1289, HA Dens Deck Prime, SECUROCK HA SBS-SA more SBS- SA, SBS TA -60.0 at max. 24 Elastobase (square) with equally spaced, type II polyiso- Gypsum -Fiber Roof Board SA or APP- or APP-TA Inch spans Poly Roofgrip #12 staggered center cyanurate TA rows TABL E'1B WOOD:DECKS—NEW;CONSTRIICTLON, REROOF;(TeAa=OFF) oa RECOVER SYSTEM TYPE 13 .IVIECHANICALLXATTACHEDBASE INSUI A710N;,BONDEDTOP INSULATION, BONDEp'ROOF COVER System Base Insulation Layer. Top Insulation Layer Roof'Cover (Note 15) MDP No. Deck (Note 1) (Psf) Type Fasteners Attach Type Attach Base Ply Ply Cap Ply Min. 19/32-inch Min.1.5-inch Dekfast Hex with Min. 0.75-Inch FescoBoard (Optional if (Optional if using W-7 plywood at max. 24-inch ENRGY 3, H-Shield Dekfast#12 orTruFast 1 per z (homogeneous) or min. 0.5-inch HA using AA Ply) AA Base) One or SBS-AA; SBS-TA, -60.0 spans or Polytherm MP-3 with TruFast DP 1.33 ft Structodek High Density Fiberboard BP AA more BP -AA or APP TA Roof Insulation APP TA Exterior Research and Design, I.I.C. d/b/a Trinity ERD Eva luation ep-c or Certificate of Authorization 09503 6T" EDITION (2017) FBC NON-HVH2 EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 5 of 26 �1 1 KINITY I ERD .._ TABLE 1C: WOOD.DECKS_; NEW CC{NSTRILCT.PN, RERQOF.(TEAR-OFF) oR RECOVER SYSTEM TYPE C:"MECHANICALLYATTACHED.INSULATION, BONDED ROOF COVER System Deck (Note i) Base Insulation Top Insulation Layer Roof Cover (Note 15) MDP Type Fasteners Attach Base Ply Ply Cap Ply No. Layer (Psf) Min.19/32-inch (Optional) Min, 0.5-inch Structodek High Density Dekfast Galvalume (Optional if (Optional if using AA W-8 plywood at max. One or more layers, Fiberboard Roof Insulation or min, 0.25- Steel Hex with 1 per 1.33 Z using AA Ply) Base) One or more BP -AA SBS=AA, SBS-TA, APP- -82.5. 24-inch spans any combination, inch Dens Deck, Dens,Deck Prime or Dekfast #12 DP ft BP -AA or APP.-TA TA loose laid SECUROCK Gypsum=Fiber Roof Board (Optional) Dekfast Galvalume W-9 Min.19/32-Inch plywood at max. One or more layers, Min.1.5-inch ENRGY 3,,H-Shield or Steel Hex with Dekfast #12 DP or 1 per 1.33 SBS-SA (Optional) One or more SBS-SA, APP-SA, SBS- =B2.5 24-inch spans any combination, Polytherm TruFast MP-3 with 2 ft SBS-SA or APP-TA TA or APP l A loose laid TruFast DP TABLE 1D: WOOD,DECKS= NEIN CONSTRUCTION; REROOF (TeAR-OFF) ORRECOVER " SYSTEM TYRE DE PRELIMINARILY ATTACHED IN MECHANICALLY ATTACHED BASE•SHEET,.BONDEDBOOF COVER 4 System iJ Insulation Layers) Base Sheet Roof Cover (Note IS) MDP No. Deck (Note Type Attach Base Fasteners Attach Base Ply Cap Ply (psf) Polyglass Elastobase, Polyglass OMG Flat Bottom Plates Min.19/32-inch One or more layers, Prelim. Elastobase Poly, Polyglass G2 Base, (square) -with Roofgrip 12-inch o.c. In 4-inch lap and 12- (Optional) One SBS-AA, W-10 plywood at max. any combination Attached CertainTeed Glasbase, Firestone MB #14, Dekfast Hex with inch o.c. in two, equally spaced, or more BP -AA. SBS-TA, -52.5 24-inch spans Base, JM Perma-Ply 28, Tamko Glass Dekfast #14 or TruFast staggered center rows or APP-TA APP-TA Base or GAFGLAS #75 MP-3 with TruFast HD Min, 19/32-inch One or more layers, Prelim. Polyglass Elastobase or Polyglass Dekfast Hex with Dekfast 12-inch o.c. In 4-Inch lap and 12- One or more SBS-SA, APP-SA W-11 plywood at max. any combination Attached Elastobase Poly with poly top surface #14 orTruFast MP-3 with Inch o.c. in two, equally spaced, SBS-SA , SBS-TA or -52.5* 24-Inch spans TruFast HD staggered center rows APP-TA Min.19/32-inch One or more layers, Prelim. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates 12-inch o.c. in 4-inch lap and 12- {Optional) One SBS-AA, W-12 plywood at max any combination Attached Elastobase Poly (square) with Roofgrip #12 inch.o.c, in two, equally spaced, or more BP -AA SBS-TA, -60.0 24-Inch spans staggered center rows or APP TA APP-TA Min.19/32-inch One or more layers, Prelim. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates 12-inch o.c. in 4-inch lap and 12- One or more SBS-SA, APP-SA, W-13 plywood at max any combination Attached Elastobase Poly with poly top surface (square) with Roofgrip #12 inch in two,ed SBS-SA SBS-TA or 60.0• 24-inch spans er center rows rowsyspaced' stagger APP-TA Exterior Research and Design, I.I.C. d/b/a Trinity IERD Evaluation Report A42970.10.12-R2 for 27-R2 Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 6 of 26 �J\T'�.RINITYJERD TABLE 1E 1 WOOD DECKS _ NEW.CONSTRUCTION oR REROOF,(TEAR OFF) SYSTENITYRE E:.NON-INSULATED, MECHANICALLYATTACHED BASE SWEET, BONDED ROOF COVER System Base Sheet Roof Cover (Note 15) MDP No Deck (Note 1} Base Fasteners Attach Base Ply Cap Ply (Psf) W-14 Min.15/32-inch plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-Inch o.c. in two, (Optional) SP-AA or SBS-AA, SBS-TA -45.0 Inch.spans equally spaced, staggered center rows APP TA or APP-TA W=15 Min. 15/32-inch plywood atmax. 24- Polyglass Elastobase Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two, (Optional) BP -AA or SBS-AA, SBS-TA -52.5 equally spaced, staggered center rows APP TA or APP TA inch spans Min.19/32-inch Polyglass Elastobase, Polyglass Elastobase (Optional) one or W-16 plywood at max. Poly, Polyglass G2 Base, CertainTeed 32 ga.,1-5/8-ihch diameter tin caps 8-inch o.c. In 4-Inch lap and 8-inch o.c. In three, more BP -AA or SBS-AA, SBS- 60.0 24 inch spans G.lasbase, Firestone MB Base, JM Perma- with 11 ga..annular ring shank nails equally spaced, staggered center APP-TA TA, APP-TA Ply 28,Tamko Glass Base or GAFGLAS #75 Min.19/32-inch Polyglass Elastobase or Polyglass 32 ga., 1-5/8-Inch diameter tin caps 8-inch o.c, in 4-inch lap and 8=inch o.c. in three, (Optional) One or SBS-SA, APP- W-17 plywood at max. Elastobase Poly with poly top surface with 11 ga. annular ring shank nails equally spaced, staggered center rows more SBS-SA or SA, SBS-TA or -60.0 24-inch.spans APP-TA APP-TA W-18 Min,15/32-inch plywood at max, 24- Polyglass Elastobase Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two, (Optional) BP -AA or , SBS TA -90.0 Inch spans equally spaced, staggered center rows APP-TA or -TA or APPAPP Min.19/32-inch Polyglass Elastobase or Polyglass 32 ga., 1-5/8-inch diameter tin caps 4-inch o.c. in 4-inch lap and 4-inch o.c. in four, One or SBS-SA, APP- W-19 plywood at max. Elastobase Poly with poly top surface with 11 ga. annular ring shank.nails. equally spaced, staggered center rows more S(Optional) more BS-SA or SA, SBS TA or -97.5 24-inch inch spans APP-TA APP-TA W-20 Min. 15/32-Inch plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-Inch o.c. in three, (Optional) BP -AA or SBS-AA, SBS-TA -105.0 inch spans equally spaced, staggered center rows APP-TA or APP-TA Min.19/32-inch Polyglass Elastobase or Polyglass 32 ga., 1-5/8-Inch diameter tin caps 6-inch o.c. in 4-inch lap and 6-inch o.c. ih four, (Optional) One or SBS-AA, SBS- W-21 plywood at max. Elastobase Poly with 11 ga. annular ring shank nails equally spaced, staggered center rows more BP -AA or TA, APP TA -112.5 24-inch spans APP TA 32 ga., 1-5/8-inch diameter tin caps Min. 19/32-inch Polyglass Elastobase or Polyglass with 11 ga. annular ring shank nails, 6-Inch o.c. in 4-inch lap and 6-Inch c.c. In four, (Optional) One or SBS-SA, APP- W-22 plywood at max. Elastobase Poly with poly top surface Note: Tin caps are to be primed with equally spaced, staggered center rows more APP TA SA, SBS-TA or -112.5 24-inch spans ASTM D41 primer. APP TA Exterior Research and Design, U.C. d/b/a Trinity I ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 0 EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Revision 2: 09/25/2017 Appendix 1, Page 7 of 26 �TRINITY I ERD TABLE•lE 2 WOOQ DECi(S NEW CONSTRIICTION,:REROOF (TEAR OFF OR'RECO,VER • SYSTEM TYPE E: ,NON -INSULATED, MECHANICALLY ATTACHED'BASE SHEET, BONDED ROOF COVER System Base Sheet Roof Cover.(Note 15) MDP No. Deck (Note 11 (psi) Base Fasteners Attach Base Ply Cap Ply MIn.19/32-inch Polyglass Elastobase, Polyglass Elastobase OMG.FIat Bottom Plates (square) with 12-inch o.c, in 4-inch lap and 12-inch (Optional) One or W-1 plywood at max. Poly, Polyglass G2 Base, CertainTeed Roofgrip #14, Dekfast Hex with Dekfast #14 o.c. In two, equally spaced, staggered more BP -AA or SBS-AA, SBS- -52.5 24-inch spans Glasbase, Firestone MB' Base, JM Perma- or TruFast MP-3 with TruFast HD center rows APP-TA TA, APR -TA Ply 28, Tamko,Glass Base or GAFGLAS #75 Min. 19/32-Inch Polyglass Elastobase or Polyglass Dekfast Hex with Dekfast.#14 or TruFast MP -One 12-inch o.c. in 4-Inch lap and 12-inch or more SBS- SBS-SA, APP- W-2 plywood at max. Elastobase Poly with poly top surface 3 with TruFast HD o.c. in two, equally spaced,,staggered SA SA, SBS TA or -52.5* 24-inch spans center rows APP-TA Min. 19/32-inch Polyglass Elastobase or Polyglass OMG Flat Bottom Plates,(square) with . 12-Inch o.cin 4,Inch lap and 12-Inch (Optional)One or SBS-AA, SBS- W-3 plywood.at.max. Elastobase Poly Roofgrip #12 o.c. in two, equally spaced, staggered more BP -AA or TA, APP-TA -60'.0 24-inch spans center rows APP-TA Min. 19/32-inch Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) with . 12-inch o.cin 4-inch lap and 12-inch One or more SBS- SBS-SA, APP- W-4 plywood at max. Elastobase Poly with poly top surface Roofgrip #12 o.c. in two, equally spaced, staggered SA SA, SBS-TA or -60.0* 24-inch spans center rows APP TA TABLE 1F :WOOD DECKS NEW CONSTRUCTION odREROOF (fiiA OFF). • ' SYSTEM TYPE F:HON-INSULATED, BONDED ROOF COVER System Deck Primer Roof Cover (Note 15) MDP Joint Treatment Base Ply Ply Cap Ply No (Psi) IVhn-15/32-Inch plywood - , -� D4D — None, ional)'S i OptBS-SA 6r3 ( SBS PP _SA,.A_SA;.SBS-TA- - - at:max�24;(nch pans, _.(Optional):ASTM W 6 Min.15/32-inch plywood (Optional) ASTM D41 Plywood joints are covered with 4-inch wide strips of TriBuilt SA TriBuilt SA SBS Base (Optional) SBS-SA or SBS-SA, APP-SA, SBS-TA '9T5 at max. 24-inch spans SBS Base, rolled into place to create continuous bond. APP.TA or APP-TA Exterior Research and Design, I.I.C. d/b/a Trinity ERD Evaluation Report A42970.10.12-R2 for FL16027-RZ Certificate of Authorization#9503 C" EDITION (2017) FBC NON.HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems, (800) 516-1485 Appendix 1, Page 8 of 26