Loading...
HomeMy WebLinkAboutLETTER ABOUT ROOFING SPECIFICATIONrchit¢ctanic Inc ptember 7, 2018 SC Y® jYki ESS VED �f Lucie Count int Lucie County Building Department y tn: Roof Permit Plan Review 2018 00 Virginia Avenue Pierce, FL 34982 EY, t ymltting Re:. Roofing specification prepared.for the St. Lucie County Building Dept. for the structure located at 8101 Coquina Avenue, Saint Lucie County, Florida anufacturer: Polyglass USA. ofiles; Modified Bitumen Roof System, FL #1654-R22 de: FBC 2017; Section 1507 ind Speed: 160 MPH; Ultimate Design Wind Speeds posure; C Ban Roof Height: 30' Maximum ;ch: 2/12 Minimum quired Design Pressure: Zone1: -31.46 Zone 2: -49.61 Zone3: -68.97 Rximum Uplift Pressure: -90 psf se: SBS-SA (self- adhering) r Sheet: (Optional) One or more SBS-SA, (self -adhering) SBS-TA, APP-TA p: SBS-SA, APP-SA, SBS-TA, APP-TA of Decking: Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank @ 6" O.C., thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2, and 4" O.C. thru out zone 3. The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. �. ......' G 4 1 Eo 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1