Loading...
HomeMy WebLinkAboutMOBILE HOME INSPECTION REPORTAll rei comp All us Owne Addre Year / Width_ C=In St Lucie County Building & Zoning 2300 Virginia Avenue Ft Pierce. FL 34982 SCANNED BY Mobile Home Inspection Report St Lucie County ests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this id Inspection Report and copies of both sides of the Title to the home. Mobile homes must be Wind Zone II certified. \AIY/U/ E & D& COR P Date: l�J (Print or type) 519M iM L-AkV5 &TOO SPAN16H Limei 154,vD. Fr R Q q Ena FL rA IRWAYS M.HP (P sLocationo�aA� f M8SP4a&317 9A FiA74429 Aanufacturer ! / Serial #FLmSSPyN1 7.Z98 HUD' Plate # LA 176 6 30 Length (00(07 Single Doubleye Wind Zone N = Not in Compliance Fire Safety / Electrical 1. Smoke Detector: Installed V : Missing 2. Electrical System Checked: Exposed Wiring Other 3. Distribution Panel: Missing Loose Main Missing Breaker Unplugged Opening Other jj�oti —o(2 ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIAN REVIEWED BY DATE of NA51jO 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire THESE PLANS AND ALL PROPOSED WORE; GFCI receptacles not where required ARE SUBJECT TO ANY CURECTIONS Gui 5. Electrical Ground: Chassis Main Panel Gas Pipe REQUIRE0 DY Fi= INSPECT ORS THAT UAYBE NECESSAW IN ORDER TO OOPLYWITH A! L APPMAKUP CODES, CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE 3/9105 Page 1 of 3 CONTRACTOR OF RECORD i l Construction 0 Exit Doors Operable: Front Back Other _�. Exit Door Locks: Missing Inoperable �91 G Egress windows: Missing Inoperable Windows: Broken Glass Inoperable 5. Screens: Missing Damaged 6. Floor System: Joist Decking Area Damaged i 7. Interior Paneling: Missing Loose Damaged Rodent Proofing: Bottom Board Pipe openings Other Leaks Apparent: Ceiling Doors Floor Roof �'ih 0. Vertical tie -down straps: Missing Short Damaged 11. Structural modifications since manufactured: YES_ NO_[ 12. Walls: Structurally Unsound Loose Weather tight �j riumbing 'll G 1. Trap: Missing Not connected Other G '12. Plumbing fixtures: Missing Not installed Not Vented I w i 3. Relief Valve: Missing Inoperable Other Drain Waste and Venting Piping: Missing Not supported Clean outs Use of fittings Not capped i Heating and Air Conditioning 1. Heating Appliances: Missing Not Connected Other. 2. Deleted Heating/AC system: Not installed Other, 3. Thermostat: Missing Inoperable 4. Air registers: Missing Inoperable Cif 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 0 . Gas furnace Water heater vent: Missing Loose lil , % Return Air: To Furnace To A/C From rooms I r it Range: Vent Hood . Gas Valve: Accessible Installed improperly ICI 0. Gas lines: Not capped Not supported Kinked I,I Not bonded u Sum ary 1. Is Ilsubject structure found to be fifty (50%) or more damaged or deteriorated? YES NO V 2. Will a remodeling permit be required? YES NO Y The pr 4lvisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than thlolI se standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be limited'to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PE:� FORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPI'Il RATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUSTCOBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO AAIIIIiOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX THEIR SEAL. Date i Inspected: p 3`�3J8 Inspe ted By: V I . , License # Sign ure required 2 � / a0 8 Phone Number: � 3 a Engineers Seal Page 3 of 3 STEVEN G. WOOD, P.E. FL LICENSE 34398 960 SULTAN DR FORT ST LUCIE, FL