HomeMy WebLinkAboutEVALUATION REPORTTE-R
ST. L
REVI
REVI
DATE
PLAN
SITE
1''W CREEK
TECHNICAL SERVICES, LLC
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 6T" EDITION (2017)
Manufacturer: ATLAS ROOFING CORPORATION Issued September30, 2017
2000 Riveredge Parkway, Suite 800
Atlanta, GA 30328
(770) 612-6267
www.atlasroofing.com FILE C
Quality Assurance: UL LLC (QUA9625)
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBIU16Y OF THE
SCOPE CONTRACTOR OR RECORD
Category: Roofing SGANNEE)
Subcategory: Underlayments BY
Code Sections: 1507.1.1, 1518.4, 1523.1.1, 1523.6.5.2.1 4v`Y LUCjG Properties: Physical properties County
REFERENCES
Entity
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
PRI Construction Materials Technologies (TST6049)
UL LLC (TST1740)
UL LLC (TST1740)
UL LLC (TST1740)
UL LLC (TST1740)
UL LLC (TST1740)
IE COUNTY BUILDING DI��ON
ED FOR COMPLIANC51',, lmll-y
AND PERMIT MUST BE
R NO INSPECTION(S)
ATL14001.4A
%ON JOB
BE MADE
Report No.
ATL-033-02-01
ATL-068-02-01
ATL-068-02-01
ATL-068-02-01
ATL-069-02-01
ATL-090-02-01
ATL-149-02-01
ATLA 64-02-01
BWR-533-02-01
BWR-543-02-01
MSA-004-02-01
MSA-007-02-01
MSA-026-02-01
WRMI-011-02-01
MSA-007-02-01
MSA-030-02-01
02-NK40952
02-NK40952
02-NK40952
02-NK40952
02-NK40952
FL17322-R4
Standard
Year
ASTM D
226
2009
ASTM D
1970
2015a
ASTM D
4798
2011(2016)
TAS 110
2000
ASTM D
1970
2015a
TAS 103
1995
ASTM D
1970
2015a
ASTM D
1970
2015a
TAS 103
1995
ASTM D
1970
2015a
ASTM D
1970
2015a
UL 1897
2012
ASTM D
1970
2015a
ASTM 1970
2015a
UL1897
2012
ASTM D
1970
2015a
ASTM D
1970
2015a
ASTM D
226
2009
ASTM D
2626
2004(2012)E1
ASTM D
4869
2016
ASTM D
6380
2003 (2013)
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK ATLAS ROOFING CORPORATION
Roofing Underlayments
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
#15 Specification Felt ASTM D 226, Type I asphalt saturated organic felt underlayment for use in the
HVHZ and non-HVHZ.
#30 Organic Saturated Felt ASTM D 4869, Type II asphalt saturated organic felt underlayment for use in the
non-HVHZ only.
#30 Specification Felt ASTM D 226, Type II asphalt saturated organic felt underlayment for use in the
HVHZ and non-HVHZ.
#43 Base Sheet ASTM D 2626 asphalt saturated and coated, non -perforated, organic felt
underlayment for use in the HVHZ and non-HVHZ.
#90 Mineral Surface Roll ASTM D 6380, Class M asphalt -saturated organic roll roofing sheet for use in the
Roofing HVHZ and non-HVHZ.
Gorilla Guard® EVERFELT 30 Asphalt -saturated organic felt underlayment reinforced with glass fiber that meets
the performance requirements of ASTM D 226, Type I for use in the HVHZ and
non-HVHZ.
Slate/Tile Underlayment ASTM D 6380, Class M asphalt -saturated organic roll roofing sheet for use in the
HVHZ and non-HVHZ.
WeatherMaster® Ice and ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a
Water 100 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
installation.
WeatherMaster® Ice and ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a
Water 200 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a split -release film, which is removed during
installation.
WeatherMaster® Ice and ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a
Water 216 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a split -release film, which is removed during
installation.
WeatherMaster® Flexible Ice ASTM D 1970 SBS modified, self -adhering underlayment with plastic film surface
and Water for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a
split -release film, which is removed during installation.
WeatherMaster® Pro -Grade ASTM D 1970.SBS modified, self -adhering underlayment with a fiberglass mat
Ice and Water reinforcement and a poly -fabric surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
installation.
WeatherMaster® Tile TAS 103 SBS modified, self -adhering underlayment with a fiberglass mat
reinforcement and a poly -fabric surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
installation.
ATL14001.4A FL17322-R4 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
ATLAS ROOFING CORPORATION
Roofing Underlayments
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
Exposure of the underlayments shall be limited to a maximum 30 days except as follows:
a) #15 Specification Felt, #30 Specification Felt, and #40 Base Sheet — exposure for than 24 hours may
adversely affect product performance
b) WeatherMaster@ Ice and Water 100, WeatherMaster@ Ice and Water 200, and WeatherMaster@ Ice
and Water 216 — maximum 30 days
c) WeatherMaster@ Pro -Grade Ice and Water and WeatherMaster@ Flexible Ice and Water — maximum
30 days
d) WeatherMaster@ Tile — maximum 90 days
Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
Roof coverings shall be mechanically fastened through the underlayment to the roof deck except as follows (or as
indicated in other current FBC product approval documents): I
a) WeatherMaster@ Pro -Grade Ice and Water or WeatherMaster@) Tile — ICP Adhesives Polyset AH-160
b) Slate/Tile Underlayment or #90 Mineral Surface Roll Roofing — Convenience Products Touch n' Seal
StormBond Roof Tile Adhesive, Dow TileBond, or ICP Adhesives Polyset AH-160
Allowable Roof Coverings:
Metal Roof
Composite or
Wood
Asphalt
Panels and
Photovoltaic
Shingles and
Slate
Clay and
Underlayment
Shingles
Shingles
Shingles
Shakes
Shingles
Concrete Tile
#15 Specification Felt
Y
Y
Y
YZ
Y
N
#30 Organic Saturated Felt
Y
Y
Y
Y
Y
N
#30 Specification Felt
Y
Y
Y
Y
Y
Y
#43 Base Sheet
Y
Y
Y
N
Y
Y
#90 Mineral Surface Roll Roofing
Y1
N
N
N
N
Y
Gorilla Guard® EVERFELT 30
Y
Y
Y
YZ
Y
N
Slate/Tile Underlayment
Y'
N
N
N
N
Y
WeatherMaster@ Ice and Water
Y
Y
Y
N
Y
N
100
WeatherMasterO Ice and Water
Y
Y
Y
N
Y
N
200
WeatherMaster@ Ice and Water
Y
Y
Y
N
Y
N
216
WeatherMaster@ Flexible Ice and
Y
Y
Y
N
Y
N
Water
WeatherMaster,& Pro -Grade Ice
Y
Y
Y
N
Y
N
and Water
WeatherMaster@ Tile
Y
Y
Y
N
Y
Y
Notes: 1) Open valley applications per 1507.2.9.2
2) Wood shingles only
ATL14001.4A FL17322-R4 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
0 CREEK ATLAS ROOFING CORPORATION
Roofing Underlayments
TECHNICAL SERVICES, LLC
WIND RESISTANCE (NON-HVHZ ONL
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
Underlayment System No.1 — WeatherMaster® Tile only
Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c.
Underlayment: WeatherMaster® Tile shall be fully adhered to the optionally primed plywood deck.
Maximum Design -52.5 psf
Pressure:
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Roof slope limitations shall be in accordance with FBC requirements.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Products described within this report may be used as described in other current FBC product approval
documents.
5) Roof coverings shall not be adhered directly to the underlayment unless otherwise approved in this or other
current FBC product approval documents.
6) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the Florida Building
Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
No 74021
'. S TAT E O F
Al
�//llnll�
CERTIFICATION OF INDEPENDENCE
2017.09.30
12:44:22
04'001
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
ATL14001 AA FL17322-R4 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.