HomeMy WebLinkAboutMOBILE HOME INSPECTION REPORTAll
All
St Lucie County Building & Zoning
2300 Virginia Avenue
Ft Pierce, FL 34982
Mobile Home Inspection Report �Q y
P p �tLuc/e cou,,t
y
for permits to place or replace used Mobile / Manufactured homes must be accompanied by this
Inspection Report and copies of both sides of the Title to the home.
Mobile homes must be Wind Zone II certified.
WYNNE SLID& CORP Date: a oZ �pb
(Print or type) I 5 ,0.410 I S 14 LAKES
Address: & T/.,
Year'
Manufacturer
Width ;L ! ,
C = I , Compliance
POT-, roR-r Ptcwu � cn R �/AY�js, NI ttP
(Physical Loca ion of Home) FLHM6S PytG3Rso5A FLI,'t� e&16 9
99a Or ° Serial #I'LWBSP'ij021r05&UD Plate # ri.A 4ib&q 90
i
Length 3 Single
N = Not in Compliance
Doubley Wind Zone
Fire Safety / Electrical
C'v r-`."
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR COMPLIA
REVIEWED BY
DATE .g /z5 I/S3
1. Smoke Detector: Installed Missing
PLANS AND PMIT
MUST BE KEPT OOB OR
r
2. Electrical System Checked: Exposed Wiring Other
NO INSPECTION WIBE MADE
3. Distribution Panel: Missing Loose Main Missing
Breaker Missing
Unplugged Opening Other
4. Electrical Fixtures: Missing Installed Improperly
THESE PLANS AND ALL PROPOSED WORK
Improperly Wired Loose Wire
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED SY FI LU IRSREC TORS THAT
GFCI receptacles not where required
MAY DE NECESSARY IN ORDER TO
5. Electrical Ground: Chassis Main Panel Gas Pipe
COMPLY WITH ALL APPLICABLE CODES.
3/9/05
Page 1 of 3
COWAN PAIIINMI Oq ArfaMENTS
ARE THE RESPONSIRIITY OF THE
CONTRACTOR OF RECORD
, a :'" •',� �h
t
Construction
1. Exit Doors Operable: Front Back Other
�.
2. Exit Door Locks: Missing Inoperable
Egress windows: Missing Inoperable
G
4. Windows: Broken Glass Inoperable
Screens: Missing Damaged
Floor System: Joist Decking Area Damaged
7. Interior Paneling: Missing Loose Damaged
8. Rodent Proofing: Bottom Board Pipe openings Other
II
. Leaks Apparent: Ceiling Doors Floor Roof
G
10. Vertical tie -down straps: Missing Short Damaged
11. Structural modifications since manufactured: YES_ NO�
L
12. Walls: Structurally Unsound Loose Weather tight
Piumbing
Trap: Missing Not connected Other
Plumbing fixtures: Missing Not installed Not Vented
Relief Valve: Missing Inoperable Other
Drain Waste and Venting Piping: Missing Not supported
Clean outs Use of fittings Not capped
Heating and Air Conditioning
1. Heating Appliances: Missing Not Connected Other.
Deleted Heating/AC system: Not installed Other.
3. Thermostat: Missing Inoperable
Air registers: Missing Inoperable,
5. Ducts: Not sealed Missing Collapsed
Page 2 of 3
�6. Gas furnace Water heater vent: Missing Loose
Z. Return Air: To Furnace To A/C From rooms
. Range: Vent Hood
G. Gas Valve: Accessible Installed improperly
G f
Sumr
0. Gas lines: Not capped Not supported Kinked
Not bonded
0
1. Is ubject structure found to be fifty (50%) or more damaged or deteriorated? YES NO
2. W �I a remodeling permit be required? YES NO
The pr visions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent
than t se standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be
limitedto, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232
IF ANiI RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO
I
BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY,
A SEPARATEI PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS
MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT.
NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE-
LOC TED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN
SUB ITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED.
A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX
11 THEIR SEAL.
Date i ,spected:
� fxmu(-;-
p 7, q 9`
Inspected By: I .�� License # ✓ � 3 Jy
Sign t rra required
Phone Number: ((I/�1
Page 3 of 3
7y-
,S;t Al v
Engineers Seal
STEVEN G. WOOD, P.L.
pL LICENSE 34398
9SULTAN
�DR,
FORry�S LUCIE, FL