Loading...
HomeMy WebLinkAboutMOBILE HOME INSPEACTION REPORTAll com All u St Lucie County Building & Zoning 2300 Virginia Avenue Ft Pierce. FL 34982 Mobile Home Inspection Report eCott, gists for permits to place or replace used Mobile / Manufactured homes must be accompanied by this �d Inspection Report and copies of both sides of the Title to the home. Mobile homes must be Wind Zone 11 certified. Year / anufacturer I Width a / C = In Compliance LD& (Print or type) Tt gC S I 99ji*ghysical Loc, CDR t Length &Q Single N = Not in Compliance Date: 8/;z` l$ 5 fANW4 ILAK255 f-ORT NERCO 1- FAIRWAYS M KV 1e' FLi4MSOQ105&3 F4 534317 Serial #FL•l-fMBM30#2 UD Plate # FLA 534 3 q6 Double V/ Wind Zone_: /9001 -c7zf -,� Fire Safety / Electrical 1. Smoke Detector: Installed f✓: Missing C 2. Electrical System Checked: Exposed Wiring Other ST. LUCIE COUNTY BUILDING DIVI REVIEW FOR COM IA REVIEWED BY DATE I IVS / PLANS ANDPERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE Distribution Panel: Missing Loose Main Missing Breaker Missing Unplugged Opening Other 4. Electrical Fixtures: Missing Installed Improperly THESE PLANS AND ALL PROPOSED WORK Improperly Wired Loose Wire ARE SUBJECT MANY CORRECTIONS GFCI receptacles not where required REQUIRED BY FIEU INSPECTORS I HiAT G Electrical Ground: Chassis Main Panel Gas Pipe fi�Y DE NECESSARY IN ORDER TO CODAY WITH ALL APPLICAM- CODES. Revised 4 CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE Page 1 of 3 CONTRACTOR OF RECORD Construction 1. Exit Doors Operable: Front Back Other 2. Exit Door Locks: Missing Inoperable i 3. Egress windows: Missing Inoperable 4. Windows: Broken Glass Inoperable 5. Screens: Missing Damaged 6. Floor System: Joist Decking Area Damaged 7. Interior Paneling: Missing Loose Damaged 8. Rodent Proofing: Bottom Board Pipe openings Other G 19. Leaks Apparent: Ceiling Doors Floor Roof 10. Vertical tie -down straps: Missing Short Damaged C 11. Structural modifications since manufactured: YES_ NO_je!�' 12. Walls: Structurally Unsound Loose Weather tight r iumbiing Trap: Missing Not connected Other Plumbing fixtures: Missing Not installed Not Vented Relief Valve: Missing Inoperable Other Drain Waste and Venting Piping: Missing Not supported Clean outs Use of fittings Not capped Heating and Air Conditioning Heating Appliances: Missing Not Connected Other G . Deleted Heating/AC system: Not installed Other I. Thermostat: Missing Inoperable. C. Air registers: Missing Inoperable �pl i. Ducts: Not sealed Missing Collapsed Page 2 of 3 6. Gas furnace Water heater vent: Missing 7. Return Air: To Furnace To A/C 8. Range: Vent Hood ti Loose From rooms Gas Valve: Accessible Installed improperly 0. Gas lines: Not capped Not supported Kinked Notbonded Sum ary 1. Is ubject structure found to be fifty (50%) or more damaged or deteriorated? YES NO_—V/— 2. W I a remodeling permit be required? YES NO$V/_ The pr visions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than th se standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be limitedly o, standards for structural adequacy, plumbing, heating, electrical systems, and fire and fife safety. FS 320.8232 IF ANYi'IlRENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PE FORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEP'IILIRATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST' liTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MCI BILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCAIIITED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A RE ISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX THEIR SEAL. Date in clad: A � ' •. ' p 33g8 Inspect � By: V J I . �, License # signitture required ._ a 4 0 Phone umber: 3 C� Engineers seal Page 3 of 3 STEVEN G. WOOD, P.E. FL LICENSE 34396 goo SULTAN DR FORT ST LUCIE, EL