Loading...
HomeMy WebLinkAboutLETTER ABOUT ROOFING SPECIFICATIONSit Architect66"Ic Inc September 14, 2018 RECEIVED ,Saint Lucie County Building Department/ SCP 7..013 4ttn. Roof Permit Plan Review `uC� II C� ST. Lade COUnty, Permitting 2300 Virginia Avenue 4n---- Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County'Building Dept. for the structure located at 128 SE Castana Court, Saint Lucie County, Florida Manufacturer: Polyglass USA rofiles: Modified Bitumen Roof System, FL 41654-1122 ode: FBC 2017; Section 1507 Vind Speed: 160 MPH; Ultimate Design Wind Speeds xposdre: C lean Roof Height: 20' Maximum itch: 1.5/12 Minimum equired Design Pressure: Zone1; -31.46 Zone 2: -49.61 Zone3: -68.97 laximum Uplift Pressure: -90 psf ase: SBS-SA (self- adhering) ly Sheet: (Optional) One or more SBS-SA, (self -adhering) SBS-TA, APP-TA ap: SBS-SA, APP-SA, SBS-TA, APP-TA oof Decking: Existing 5/8", plywood sheathing to be nailed w/8d x 2" ring shank @ 6" O.C. thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2, and 4" O.C. thru out zone 3. above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, the Manufacturer's recommendations. �spe'ctfully subm f{ 0 I`i^hhael eal ,rk� FILE COPY �$ec, onic Ing,.-',j.�� TFRE® PRG Delaware Avenue Tel: 772 460 7151 www.architectonicinc.com Pierce, Florida 3495o Fax: 772 460 4244 FL Reg #AA26003348 1 of 1