Re: Roofing specification prepared for the St. Lucie County'Building Dept. for the structure
located at 128 SE Castana Court, Saint Lucie County, Florida
Manufacturer: Polyglass USA
rofiles: Modified Bitumen Roof System, FL 41654-1122
ode: FBC 2017; Section 1507
Vind Speed: 160 MPH; Ultimate Design Wind Speeds
xposdre: C
lean Roof Height: 20' Maximum
itch: 1.5/12 Minimum
equired Design Pressure: Zone1; -31.46 Zone 2: -49.61 Zone3: -68.97
laximum Uplift Pressure: -90 psf
ase: SBS-SA (self- adhering)
ly Sheet: (Optional) One or more SBS-SA, (self -adhering) SBS-TA, APP-TA
ap: SBS-SA, APP-SA, SBS-TA, APP-TA
oof Decking: Existing 5/8", plywood sheathing to be nailed w/8d x 2" ring shank
@ 6" O.C. thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2,
and 4" O.C. thru out zone 3.