Loading...
HomeMy WebLinkAboutCERTIFICATION DEESIGN LOAD COMPLIANCEPlanning & Development Services Department i I Building & Code Regulations Division 4 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 4624SS3 Certification for Design Load Compliance SCANNED BY Project Name: 3600 Sq. Ft. Hangar c, a OUfrlty Project Address: 12366 Lear PI Port St Lucie, FL 34981 ccupancy Type: _—Construction Typ Permit #: 1809-0316 INSTRUCTIONS FOR USE: This certification must be completed, signed, and sealed the design profess) c• volving the following: Submit (2) copies for residential, (3) copies for commercial al with all permit applications involving • o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. terior structural elements are * Note: Form not required for interior renovationsprovided that no e he local building official. Contact the #above for questions. d an certain minor building permits at the discretion of t DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Code Fifth Edition with 20 Supplements using ASCE 7-10 x Enclosed Partially Enclosed X Open 2. Structure Designed as (check one): 3. Risk Category: —I B X C D X II III IV Exposure Category: ft 4. Design Wind Velocity 165 _mph ASD X LRFD End Zone Width: n/a _ 5. Mean Roof Height n/a ft Roof Pitch: n/a ;12 Parapet: Na ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 2: Zone 1: 49.3 n/a Zone 3: n/a Zone 4: n/a Zone 5: n/a Garage: n/a 7. Design Loads: Floor: n/a PSF Roof/Dead: n/a PSF Roof/Live: n/a Balcony: Na PSF Dock: n/a PSF Deck: n/a PSF Stairs: n/a PSF Fence: n/a PSF Railings: n/a PSF 8. Were Shear Walls Considered For Structure? Yes X Not Applicable Explain Why Not: Door is not a shear wall for the structure. 9. Is A Continuous Load Path Provided? Yes n/a Not Applicable Explain Why Not: Door is not part of the load carrying path for the building structure. 10. Design Soil Bearing Pressure: n/a PSF Soil Test Reports Submitted? n/a Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans &specifications have been designed to applicable structural portions of the building codes currently adopted and enforced by St. Lucie the a comply with pp n these lans provide adequate resistance to the design County. I also certify that structural elements depicted o p <a11ililk specified: PE License 73476 Jeff Bartoszek, P.E. s o a 9\! 73476 ®-0 ;. Signature , and Seal m S TE OF U ooi���< ®; ` e25/2014 Print Name P.O. Box 766, St. Joseph, MI 49085 Company Name & Address Cert # & Co. Cert Auth. IVEE DEC 14 2018 Permitting Departmer Cf- 1 . r1