HomeMy WebLinkAboutPRODUCT REPORT - UNDERLAYMENTPalm City, FL 34990 II DYNE® Co I� pliant with Florida Building Code 2017 (6�' ed.) C Co �l pliant with Florida Product Approval Rule # 61G20-3 St Lucie County Compliant: Keystone Certifications Pro duct: 5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ min. OA2 specific gravity with screws: 24" Coverage Rib Height 3/8" Cor P osion Resistant Compliant: FBC Sec.1507.4.3 Fas' �ener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to enetrate 3/1!�p" min, thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet Fastener 2 (Method 2,3, & 4 Attachment)::#10 x 1=1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru-deck or 5/8" embedment into wood plank. (*or sufficient length 11 to meet requirements) Unp,erlayment: To be compliant with FBC Sec. Chart 1507.1.1 Sloe: 11 Shall be in compliance with FBC Sec..1507. See Fastener attachment specifications above Inst ,11 Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESI,ON PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING 16" o.c. 16" o.c. 8" O.C. 6" o.c. FASTENER SPACING (ALONG Panel width) 22" o.c. 12" o.c. 12" o.c. 12" O.C. FASTENER SIZE #9 #10 #10 #10 UL 51 TAS *EQL Locke under Locke Data: ARCHITECTURAL TESTING, INQ TST ID#:1527 &.1897-041 Test Report 1015893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 3 Test Report D05893.02-450-18 07/22/14 NCY-UL 1897-04 Is equivalent to test standard UL 1897-�� f1� *Design pressure margin of safety 2:1 ..nn�... den, P.A. does not have, not will acquire a,f+nancial evaluation. den, P.E. Is not owned, operated, or controlled by i fr9 `�cq - rJf; m�iafacturieg or distributing products compa.ftimbbilfakturer, ori7stributing products under this • M f y ROP l / '�,c�S'r ' ... + • . ONAI. i-*'' 1. Und 2. Mini 3. Pro( 4. Engl 5. Fire 6. SupI Stru 7. This FL17O22.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details Ilayment to be compliance with current Florida Building. Code (FBC)2017 6th ed. um slope to be compliant with Florida Building Code 2017 611, ed., and per with Manufacturer's installation reference. cts are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D eering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. assification is not part of this acceptance. Shear diaphragm values are outside this report. ►rt framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for ural Loading. :port does not imply warranty, installation, recommended product use outside of this report. Fasteners - !9.1.01SI1,W-asher 1-117'Min. or 1-117' Min. perfibb 141 IorRow S-VCrimp Roof Panel acing and Design Pressures Head Wood Screws Dells: -15132' or greater Plywood. or • Wood plank 7}I" 1?" 316" Panel Profile Nominal 12" Nominal 12" O.C. O.C. Fasten 9 x 1-1/2" Min. or #10 x 1-1/2" Min. per able "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel VUdth Panel - Refer to Table "A" for Spacing Along Panel Overlap Length Deck-15/32" or greater Plywood, or -Wood plank