NOA is being issued under the applicable rules and regulations governing the use of"consir�i�t�cirii t�r�agGggS-
,Imentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
i in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
Thi NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Se ion (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
rev'ike, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
rev ke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
ma erial fails to meet the requirements of the applicable building code.
product is approved as described herein, and has been designed to comply with the Florida Building Code
ding the High Velocity Hurricane Zone of the Florida Building Code.
Titanium® UDL-30 / Titanium® PSU-30, Titanium® UDL-25 PLUS / Titanium® PSU-30,
and UDL-MD (2 ply) / Titanium® PSU-30 Underlayment System
TG: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
"Miami -Dade County Product Control Approved", unless otherwise noted herein.
NEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
T RMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for I' ales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
"ECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
be available for inspection at the job site at the request of the Building Official.
NOA renews and revises NOA# 13-0730.01 and consists of pages 1 through 7.
submitted documen-ta�tion was revie ed ylex T'gera
.4032,b
IIAMI•DADE COUNTY
� , • • •. � ST. L IE COUNTY gUIL Y G
REVIEWED FOR COMPLIANC /
REVIEWED BY (�
DATE
PLANS AND PERMIT MUST BE KEP/oA JOB
SITE OR NO INSPECTION(S) WI MADE
CONCEALED FASTENERS OR ATTACHMENTS
AR4,THE RESPONSIBILITY OF THE
CONThACTOR OR RECORD
NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17
Page 1 of 7
PL
FING COMPONENT APPROVAL
ory: Roofing
,ategory: Underlayment
-ial• Polypropylene
NAMES OF PRODUCTS MANUFACTURED BY APPLICANT
TABLE 1
Product Dimensions Test Product
Specification Description
L® UDL-25 48" x 250' rolls ASTM D226 Woven synthetic polymer underlayment with one
Type I & H side coated with UV protected and slip resistant
. polymer stabilized polypropylene on both sides.
#1& #2
(2P1y system)
48" x 250' rolls ASTM D226
Woven synthetic polymer underlayment with a
Type I & II
chemical slip resistant and UV protected coating on
`wring
both sides.
#2
i® UDL-30
48" x 250' rolls ASTM D226
Woven synthetic polymer underlaymentwith two
Type I & H
sides coated with UV protected and slip resistant
wring
polymer stabilized polypropylene on both sides.
#1& #2
i@ PSU-30
36" x 72' rolls TAS 103
Unreinforced polymer modified bitumen material
adhered to the underside of a polymer -coated,
Wring
synthetic woven sheet. The underside is backed
#3
with a release film.
UFACTURING LOCATIONS:
ML 1
ML3
ML4
NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17
Page 2 of 7
i
E ENCE SUBMITTED:
Test Agency
Irate Lek Testing Services
ini�y I ERD
Test Identifier
#3031783
3124826-01
3119607COQ-003B
3130639COQ-002A
3124826MID-007
3146738COQ-003B
3146738COQ-003A
I35520.06.11
I35520.06.11
I38010.08.11
I35520.08.11-1
I35520.08.11
I44970.07.13-R1
Test Name/Report
Date
TAS 104
02/19/03
ASTM E108
02/19/08
ICC-ES AC48
02/20/08
ASTM D226
02/20/08
ASTM E108
02/25/08
ASTM D 1876/ TAS 117
03/28/08
ASTM D226
04/22/08
TAS 103 / TAS 104
06/15/11
TAS 103 / TAS 104
06/15/11
ASTM D226
08/11/11
TAS 114
08/12/11
ASTM D2523 / D178.1
08/17/11
ASTM D226, ASTM D1876
09/09/13
and TAS 114(C)
NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17
Page 3 of 7
ROVED TITANIUM UNDERLAYMENT SYSTEM ASSEMBLIES:
Type 1: Wood
Description: 19/32" or greater plywood or wood plank
n E(1): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
All fyeneral and System Limitations shall apply.
sheet: One or more plies of Titanium® UDL-25 PLUS or Titanium® UDL-30 applied with
minimum 4" horizontal laps and minimum 6" vertical laps and mechanically fastened as
noted below.
Note: Titanium® UDL-30 shall be inverted to provide a smooth bonding surface. Primer is
not required when Titanium® UDL-30 is installed inverted (printed side facing down)
Miami -Dade approved nails & metal/tin caps spaced 6" o.c. at the 4" horizontal laps and 8"
o.c. in a grid pattern having three, equally spaced, staggered rows in the field of the sheet.
Metal/Tin caps shall be primed with ASTM D41 primer
Ply heet: (Optional) Titanium® PSU-30, self -adhered with minimum 3" horizontal laps and minimum
6" vertical laps.
brane: Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6"
vertical laps. Place the first course of Titanium® PSU-30 parallel to the eave and field,
using a heavy pressure roller under safe conditions to further secure the membrane.
Approved for asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal
roofing, wood shakes & shingles or slate roof assemblies.
Note: For tile roof assemblies, refer to RAS 118, 119 or 120 and the tile manufacturer's NOA. For
foam -on tile roof assemblies, approved use with ICP Adhesives Polyset AH-160 and Dow
TILE BOND Roof Tile Adhesive.
NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17
Page 4 of 7
Type 1: Wood
Description: 19/32" or greater plywood or wood plank
m. E (2): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
All
sheet:
Ply
N
and System Limitations shall apply.
One or more plies Titanium® UDL-30 applied with minimum 4" horizontal laps and
minimum 6" vertical laps and mechanically fastened as noted below.
Miami -Dade approved nails & metal/tin caps spaced 6" o.c. at the 4" horizontal laps and 8"
o.c. in a grid pattern having three, equally spaced, staggered rows in the field of the sheet.
Titanium® UDL-30 shall be primed on the printed side with ASTM D41 primer prior to
placement of cap sheet.
(Optional) Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum
6" vertical laps.
Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6"
vertical laps. Place the first course�of Titanium® PSU-30 parallel to the eave, using a heavy
pressure roller under safe conditions to further secure the membrane.
Approved for asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal
roofing, wood shakes & shingles or slate roof assemblies.
For tile roof assemblies, refer to RAS 118, 119 or 120 and the tile manufacturer's NOA. For
foam -on tile roof assemblies, approved use with ICP Adhesives Polyset AH-160 and Dow
TILE BOND Roof Tile Adhesive.
NOA No.: 14-0603.19
Expiration Date: O1/26/22
Approval Date: 02/02/17
Page 5 of 7
' I
Deck Type 1: Wood
De Ilk Description: 19/32" or greater plywood or wood plank
Sys l em E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
All General and System Limitations shall apply.
sheet: One or more plies of UDL-MD (2Ply system) applied with minimum 4" horizontal laps and
minimum 6" vertical laps and mechanically fastened as noted below.
Miami -Dade approved nails & metal/tin caps spaced 6" o.c. at the 4" horizontal laps and 8"
o.c. in a grid pattern having three; equally spaced, staggered rows in the field of the sheet.
Ply heet: (Optional) Titanium® PSU-30, self -adhered with minimum 3" horizontal laps and minimum
6" vertical laps.
Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6"
vertical laps. Place the first course of Titanium® PSU-30 parallel to the eave and field,
using a heavy pressure roller under safe conditions to further secure the membrane.
Approved for asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal
roofing, wood shakes & shingles or slate roof assemblies.
Note: For tile roof assemblies, refer to RAS 118, 119 or 120 and the tile manufacturer's NOA. For
foam -on tile roof assemblies, approved use with ICP Adhesives Polyset AH-160 and Dow
TILE BOND Roof Tile Adhesive.
NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17
Page 6 of 7
PERMIT REQUIREMENTS
for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly
evaluate the installation of this material.
1.
2.
3.
4.
5.
6.
7.
8.
M
ATIONS
Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
Titanium Synthetic Underlayments shall be applied to a smooth, clean and dry surface with deck free of
irregularities. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking
panels. Sweep the deck. thoroughly to remove any dust and debris prior to application.
Titanium® UDL-25 PLUS / Titanium® PSU-30, 'Titanium® UDL-30 / TitaniumS PSU-30, UDL-MD (2Ply
system) / Titanium® PSU-30 two-ply underlayment system, may be used in asphalt shingle, mechanically
fastened roof tile, foam -on roof tile, metal roofing, wood shakes & shingles or slate roof assemblies.,
The standard maximum roof pitch for the Titanium® UDL-25 PLUS / Titanium® PSU-30, Titanium® UDL-30
/ Titanium® PSU-30, UDL-MD (2Ply system) / Titanium® PSU-30 two-ply underlayment system shall be 5:12
for flat tiles and 6:12 on profiled tiles with lugs. For flat tile applications at slopes exceeding 5:12, flat tiles
shall be staged 2 base tiles perpendicular to slope behind a mechanically attached batten or toe board with
maximum 7 tiles high on the slope atop base tiles (Total of stack not to exceed 9 tiles). At roof slopes greater
than the above limitations, the use of loading battens or toe boards are required to load the roof tile.
Titanium Synthetic Underlayments shall not be applied over an existing roof membrane as a recover system.
Titanium(& UDL-30 / Titanium® PSU-30, Titanium® UDL-25 PLUS / Titanium® PSU-30, UDL-MD (2Ply
system) / Titanium® PSU-30 two-ply underlayment system shall not be left exposed as a temporary roof for
longer than 90 days of application.
Titanium Synthetic Underlayments are components used in roof system assemblies. Roof system assemblies are
approved under a specific Notice of Acceptance. Refer to Prepared Roofing System Product Control Notice of
Acceptance for listed approval of this product with specific prepared roofing products.
Titanium Synthetic Underlayments may be used with any approved roof covering Notice of Acceptance listing
Titanium Synthetic Underlayments as a component part of an assembly in the Notice of Acceptance. If
Titanium Synthetic Underlayments are not listed, a request may be made to the Authority Having Jurisdiction
(AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate
documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results.
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo
and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County
Product Control Seal as shown below.
MIAMI-DADE COUNTY
END OF THIS ACCEPTANCE
NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17