HomeMy WebLinkAboutNOARECEIVED
SEP 1 2018
�MIAMI-DADE COUNTY
MIA I K
ST, 11-100 County, permitting
ODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DE TNT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BO. AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
N TICE OF ACCEPTANCE(NOA) www.miamidade.Eov/economv
In rwrap, Inc.
329' 3 Mission Way �11ANN®
MNV ion, BC, Canada V2V-6E4FILE COPY��
St Lucie County
SCOPE:
Thi NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
doc mentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
use in Miami Dade County and other areas where allowed by the Authority Having, Jurisdiction (AHJ).
Thi NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Sec ion (In Miami Dade County) and/or the AHJ (in areas other than Miami. Dade County) reserve the right to
M4 this product or material tested" for quality assurance purposes. If this product ormidterial fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and.the AHJ may immediately
rev ke, modify, or suspend the use'of such product or material within their jurisdiction. RER reserves the right to
rev 'eke this acceptance, if it is -determined by Miami -Dade County Product Control Section that this product or
in rial fails to meet the requirements of the applicable building code.
product is approved as described herein, and has been designed to comply with the Florida Building Code
ding the, High Velocity Hurricane Zone of the Florida Building Code.
Titanium® UDL-30 / Titanium® PSU-30, Titanium® UDL-25 PLUS / Titanium® PSU-30,
and UDL-MD (2 ply) / Titanium® PSU-30 Underlayment System
1G: Each unit shall bear a permanent label with the manufacturer's name'or logo, city, state and following
"Miami -Dade County Product Control Approved", unless otherwise noted herein.
�t�
EWAL, of this NOA shall be considered after a renewal application has been filed and there has been no change
in applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
ma 'erials, use', and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of i
, is NOA shall be cause for termination and removal of NOA.
A ,iVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
exf iration date may be. displayed in advertising literature. If any portion of the NOA is displayed, then it shall be. done
in i is entirety.
'ECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
be available for inspection at the j ob site at the request of the BuildingOfficial.
NOA renews and revises NOA# 13-0730.01 and consists.of pages 1 through 7.
submitted documentation was reviewed by Alex Tigera.
/r NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17
Page 1 of 7
PL
COMPONENT APPROVAL
Roofing
y; Underlayment
Polypropylene
NAMES OF PRODUCTS MANUFACTURED BY APPLICANT
TABLE 1
Product Dimensions Test Product
Specification Description
i® UD1-25 48" x 250' rolls ASTM D226 Woven synthetic polymer underlayment with one
-Type I & II side coated with UV protected and slip resistant
polymer stabilized polypropylene on both sides.
#1& #2
(2PIy system)
48" x 250' rolls ASTM D226
Woven synthetic polymer underlayment with a
Type I & II
chemical.slip resistant and UV protected coating on
wring
both sides.
#2
i® UDL-30
48" x 250' rolls ASTM D226
Woven synthetic polymer underlayment with two
Type I & II
sides coated with UV protected and slip resistant
!wring
polymer stabilized polypropylene on both sides.
#1& #2
i® PSU-30
36" x 72' rolls TAS 103
Unreinforced polymer modified bitumen material
adhered to the underside of a polymer -coated,
!wring
synthetic woven sheet. The underside is backed
#3 '
with a release film.
.NUFACTURING LOCATIONS:
1. ML 1
2. ML3
3. ML4
NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17
Page 2 of 7
E
:NCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Testing Services
#3031783
TAS 104
02/19/03
3124826-01
ASTM E108
02/19/08
3119607COQ-003B
ICC-ES AC48
02/20/08
3130639COQ-002A
ASTM D226
02/20/08
3124826MID-007
ASTM E108
02/25/08
3146738COQ-003B
ASTM D 1876/ TAS 117
03/28/08
3146738COQ-003A
ASTM D226
04/22/08
ERD
I35520.06.11
TAS 103 / TAS 104
06/15/11
I35520.06.11
TAS 103 / TAS 104
06/15/11
138010.08.11
ASTM D226
08/11/11
I35520.08.11-1.
TAS 114
08/12/11
I35520.08.11
ASTM D2523 / D1781
08/17/11
I44970.07.13-R1
ASTM D226, ASTM D1876
09/09/13
and TAS 114(C)
NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17
Page 3 of 7
10VED TITANIUM UNDERLAYMENT SYSTEM ASSEMBLIES:
Type 1: Wood
Description:. 19/32or greater plywood or wood plank .
m E(1): Base sheet mechanically fastened to deck, subsequent cap membrane self= adhered.
A111General and System Limitations shall apply..
sheet: One or more plies of Titanium® UDL-25 PLUS or Titanium® UDL-30 applied with
minimum 4" horizontal laps and minimum 6" vertical laps and mechanically fastened as
noted below.. .
Note: Titanium® UDL-30 shall be inverted to provide a smooth bonding surface. Primer is
not required when Titanium®. UDL-30 is installed inverted (printed side facing down)
Fa �tening: Miami -Dade -approved nails & metal/tin caps spaced 6" o.c. at the 4" horizontal laps and 8"
o.c. in a grid pattern having three, equally spaced, staggered rows in the field of the sheet..
Metal/Tin caps shall be primed with ASTM D41 primer
(Optional) Titanium® PSU-30, self -adhered with minimum 3" horizontal laps and minimum
6" vertical laps.
M �inbrane: Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6"
vertical laps. Place the first course of Titanium® PSU-30 parallel to the eave and field,
using a heavy pressure roller under safe conditions to further secure the membrane. -
Approved for asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal
roofing,, wood shakes& shingles or slate roof assemblies.
No e: For tile roof assemblies, refer to RAS 118, 119 or 120 and the tile manufacturer's-NOA. For
foam -on tile roof assemblies, approved use with ICP Adhesives Polyset AH-160 and Dow_
TILE BOND Roof Tile Adhesive.
NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17
Page 4 of 7
All
Type 1: Wood
Description: 19/32" or greater plywood or wood plank
n E (2): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
and System Limitations shall apply.
sheet: One or more plies Titanium® UDL-30 applied with minimum 4" horizontal laps and
minimum 6" vertical laps and mechanically fastened as noted below.
Miami -Dade approved nails & metal/tin caps spaced 6" o.c. at the 4" horizontal laps and 8"
o.c. in a grid pattern having three, equally spaced, staggered rows in the field of the sheet.
Titanium® UDL-30 shall be primed on the printed side with ASTM D41 primer prior to
placement of cap sheet.
(Optional) Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum
6" vertical laps.
brane: Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6"
vertical laps. Place the first course of Titanium® PSU-30 parallel to the eave, using a heavy
pressure roller under safe conditions to further secure .the membrane.
Nolte:
Approved for asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal
roofing, wood shakes & shingles or slate roof assemblies.
For tile roof assemblies, refer to RAS 118, 119 or 120 and the tile manufacturer's NOA. For
foam -on tile roof assemblies, approved use with ICP Adhesives Polyset AH-160 and Dow
TILE BOND Roof Tile Adhesive.
NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17
Page 5 of 7
: Type 1: Wood
L Description: 19/32" or greater plywood or wood plank
am E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
Teneral and System Limitations shall apply.
sheet: One or more plies of UDL-MD (2Ply system) applied with minimum 4 horizontal laps and
minimum 6" .vertical laps and mechanically fastened -.as noted below.-.
Miami -Dade approved nails & metal/tin caps spaced 6" o.c., at the 4" horizontal laps and 8"
o.c. in a grid pattern having three, equally spaced, staggered rows in the field of the sheet.
(Optional) Titanium® PSU-30, self -adhered with minimum 3" horizontal laps and minimum
6" vertical laps.
brane: Titanium® PSU-30, self -adhered, with minimum 3" horizontal laps and minimum 6"
vertical laps. Place the first course of Titanium® PSU-30 parallel to the eave and field,
using a heavy pressure roller under safe conditions to further secure the membrane.
Approved for asphalt shingle, mechanically fastened roof tile, foam -on roof tile, metal
roofing, wood shakes & shingles or slate roof assemblies.
No e: For tile roof assemblies, refer to RAS 118, 119 or 120 and the tile manufacturer's NOA. For
foam -on tile roof assemblies, approved use with ICP Adhesives Polyset AH-160 and Dow
TILE BOND Roof Tile Adhesive.
NOA No.: 14-0603.19
Expiration Date: O1/26/22
Approval Date: 02/02/17
Page 6 of 7
PERMIT REQUIREMENTS
Ap 'lication for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly
evaluate the installation of this material.
LI " ITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. Titanium Synthetic Underlayments shall be applied to a smooth, clean and dry surface with deck free of
irregularities. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking
panels. Sweep the deck thoroughly to remove any dust and debris prior to application.
4. Titanium® UDL-25 PLUS / Titanium® PSU-30, Titanium® UDL-30 / Titanium& PSU-30, UDL-MD (2P1y
system) / Titanium® PSU-30 two-ply underlayment system, may be used in asphalt shingle, mechanically
fastened roof tile, foam -on roof tile, metal roofing, wood shakes & shingles or slate roof assemblies.
5. The standard maximum roof pitch for the Titanium® UDL-25 PLUS / Titanium® PSU-30, Titanium® UDL-30
/ Titanium® PSU-30, UDL-MD (2Ply system) / Titanium® PSU-30 two-ply underlayment system shall be 5:12
for flat tiles and 6:12 on profiled tiles with lugs. For flat tile applications at slopes exceeding 5:12, flat tiles
shall be staged 2 base tiles perpendicular to slope behind a mechanically attached batten or toe board with
i maximum 7 tiles high on the slope atop base tiles (Total of stack not to exceed 9 tiles). At roof slopes greater
than the above limitations, the use of loading battens or toe boards are required to load the roof tile.
6. Titanium Synthetic Underlayments shall not be applied over an existing roof membrane as a recover system.
7. Titanium® UDL-30 / Titanium® PSU-30, Titanium® UDL-25 PLUS / Titanium& PSU-30, UDL-MD (2Ply
system) / Titanium® PSU-30 two-ply underlayment system shall not be left exposed as a temporary roof for
longer than 90 days of application.
8. Titanium Synthetic Underlayments are components used in roof system assemblies. Roof system assemblies are
approved under a specific Notice of Acceptance. Refer to Prepared Roofing System Product Control Notice of
Acceptance for listed approval of this product with specific prepared roofing products.
9. Titanium Synthetic Underlayments may be used with any approved roof covering Notice of Acceptance listing
Titanium Synthetic Underlayments as a component part of an assembly in the Notice of Acceptance. If
Titanium Synthetic Underlayments are not listed, a request may be made to the Authority Having Jurisdiction
(AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate
documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results.
10 All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo
and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County
Product Control Seal as shown below.
CMAMIMADECIUMNO
END OF THIS ACCEPTANCE
NOA No.: 14-0603.19
Expiration Date: 01/26/22
Approval Date: 02/02/17
Page 7 of 7