Loading...
HomeMy WebLinkAboutELECTRICAL LINE DIAGRAMCALCULATIONS SOLAR ARRAY (9.86 kW -DC r I I I I I I I I I I I F-I I II I I I I NECTABLE31ai5(B)(16) 2014NECTABLE310.15(B)(2)(a) NUNIBEEC10. NOU(TORS INVERTER : #1 zo14:NEc31a15(a)(�)(a) (1) STRING OF 12 MODULES CONNECTED TO MPPT #1. P"v-cao4- 75°C (ON ROOF)(&) (1) STRING OF 11 MODULES CONNECTED TO MPPT#2. to AwG m 4-6 - (3)-STRING-OF—I I-MODULES_CONNECTED TO_MP_P_T_#3.—__ _.—_35]AMPS_ 1 i_x_l— o.8 PV MODULE NOTE: RAPID SHUTDOWN CONTROLLER 1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE MOUNTED OUTSIDE IN ACCESSIBLE REQUIREMENTS OF THE NEC 2014, AND THOSE SET FORTH BY THE LOCATION NEXT TO ELECTRICAL METER FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDING OR OPTIONAL PV AC DISCONNECT MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OF MODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURER AND MODEL NUMBER, INVERTER MANUFACTURER AND MODEL NUMBER, AS APPLICABLE. 2 RAPID SHUT DOWN BOX IS A COMBINER BOX WITH GROUND (3) #10 AWG USE-2/PV WIRE +Red EGC #6 BARE CU IN FREE AIR #10 AWG USE-2/PV WIRE -Black FAULT PROTECTION AS PER NEC 690.5, ARC FAULT PROTECTION AS PER NEC 690.11, RAPID SHUT DOWN PROTECTION AS PER NEC 690.12, AND MANUAL DISCONNECT AS PER NEC - 690.17. LI noo ------------------------ • I (4) #18 AWG THWN-2 IN 1/2" PVC CONDUIT RUN INTERCONNECTION (N) SMA RAPID SHUTDOWN BOX I I I I I I I I I I I L--------- (3) #10 AWG THWN-2 + RED (3) #10 AWG THWN-2 - BLACK EGC #10 AWG THWN-2 IN 3/4" PVC OR CONDUIT RUN " USE METAL RACEWAYS FOR ANY DC CIRCUITS ENTERING BUILDING PRIOR TO INVERTER DC DISCONNECTING MEANS PER 690.31 1 ELECTRICAL LINE DIAGRAM E-01 SCALE: NTS 120% RULE - CEC 705.12(D)(2)(3)(b) UTILITY FEED + SOLAR BACKFEED 200.0 A + 40A = 240A BUSS RATING x 120% (N) INVERTER: #1 200.0 A X 120% = 240A SB7.7-1 SP-US-40 OUTPUT: 240 VAC, 32A 97.2% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT (N) AC DISCONNECT: ti (N) PV METER 240V, 60AMP FUSED (SMUD/GRIDLEY ONLY) NEMA 3R, UL LISTED P — + — F61 G G FINI FL LII, (IF REQUIRED) WITH 60A FUSES I I I I I I I L — — — (3) #8 AWG THWN-2 (1) #10 AWG THWN-2 GND IN 3/4" PVC CONDUIT RUN INVERTER #1 SPECIFICATIONS MANUFACTURER SUNNY BOY INVERTER MODEL # SB7.7-1SP-US-40 NOMINAL AC POWER 7.7KW NOMINAL OUTPUT VOLTAGE 240V NOMINAL OUTPUT CURRENT 32 A (3) #8 AWG THWN-2 IN 3/4" PVC CONDUIT RUN RAPB)SHUMOWN BOXTOBJYERTER " WIREAMPACITY2014 THERMAL BERATE FAdOR NUMBER OfCONbUCTORS NEC TABLE31a]Sj8)(16)` 2014NECTABIE31015(B)(2)(a)' 2014NEC31a151811311a1 DESIGNED TO PERMIT' CASTILLO ENGINEERING SERVICES, LLC -- COA928345 --- 2925 W. STATE ROAD 434, SUITE 111 LONGWOOD, FL 32779 TEL (407) 474-9181 ERMOCRATES E. CASTILLO - FL PE 52590 DESCRIPTION I DATE WIREAMPAaTY2014 7HERMALDERATEFACTOR NEC TABLE 31a15(B)(16) NUMBER OF CONDUC(ORS 2014 NECTABLE31015(B)(2)(a) 2014 NBC310.15 (B$3)(a) THWN-2-75°t (c.) PROJECT INSTALLER 8 AWG" 30 0-3 50 AMPS X1 1 x 1 TO UTILITY GRID BI-DIRECTIONAL UTILITY METER o 1-PHASE, 240V L1 L2 N (E) MAIN DISTRIBUTION PANEL, 200A RATED, 240V. L1 L2 N LINE SIDE TAP USING POLARIS TAPS OR INSULATION PIERCING IN COMPLIANCE WITH NEC 705.12(a) (E) MAIN BREAKER 240V, 20OAl2P ,•Siiggpffir "th Seal e 0 vo pF Qq 01 0 %• ••, PROJECT NAME uyov 1 2 2018 U W >� (� > Co 40A/2P (p i�j� sly LL Z W L1 Ll��le �'®�(� U L2 Z W SOLAR MODULE SPECIFICATIONS MANUFACTURER SOLARWORLD MODEL # SOLARWORLD SW-290 PMAX 29OW VMP 31 AV IMP 9.33A VOC 39.9V ISC 9.97A MODULE DIMENSION 65.95'L x 39.4"W x 1.26"D (In Inch) LEXISTING GROUNDING ELECTRODE SYSTEM PROVIDE GROUNDING ELECTRODE CONDUCTOR FROM THE INVERTER ` TO AN EXISTING SERVICE GROUNDING ELECTRODE PER 690.47(B) COPYRIGHTED BY CAS ENGINEERING SERVICE J J I"- Q U) (%) W W Lo Of m w SHEET NAME ELECTRICAL LINE DIAGRAM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS I ADC1 I 11l.ATIl - DC DISCONNECT, INVERTER (PER CODE: NEC 690.35(F)) [To be used when inverter is ungrounded] ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: NEC 690.35(F)) [To be used when inverter is ungrounded] ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC 690.17(E), CB --LABEL-LOCATION` AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC690.54) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC690.15, 690.13(B)) ADHESIVE FASTENED SIGNS: • THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING]. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.31 LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] AWARNING DUAL POWER SOURCE ` SFC(ONf) 1;C]I1RCF IS PHr]TOV()i TAIL SYSTEM LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC 705.12(D)(4)) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC690.15, 690.13(B)) INVERTER #1 LABEL LOCATION. DC DISCONNECT, INVERTER (PER CODE: NEC690.53) AC DISCONNECT, DC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC690.56(C)) DESIGNED TO PERMIT-- CASTILLO ENGINEERING SERVICES, LLC SUITE 111 LONGWOOD. FL 32779 TEL (407) 474-9151 ERMOCRATES E. CASTILLO - FL PE 52590 REVISIONS PROJECTINSTALLER 00►11111//IB ♦ I 0 . �Slgnatare I O �� C [ I 0 e 5 590 v S ATE r� s � P. PROJtf11I`, ME00 UNOV 12 201 z >Qq M 0 > LL^ W w Z W z co w� _] J Q H U) V) W W w m M CL 0 SHEET NAME SYSTEM LABELING SHEET SIZE ANSI B 11" X 17" COPYRIGHTED BY CASTILLO SHEET NUMBER ENGINEERING SERVICES, LLC E-02 TUV Power controlled: TovanelDl�a°a Lowest measuring tolerance in industry N� Every component is tested to meet 3 times IEC requirements J ® Designed to withstand heavy accumulations of snow and ice �J Sunmodule Plus: Positive performance tolerance 'J 2S25-year linear performance warranty and 10-year product warranty %Maw Glass with anti -reflective coating World -lass quality Fully-autorriated production lines and seamless monitoring of the process and material ensure the quality that the company sets as its benchmark for its sites worldwide. SolarWorld Plus -Sorting Plus -Sorting guarantees highest system efficiency. SolarWorld only delivers modules that have greater than or equal to the nameplate rated power. 25-year linear performance guarantee and extension of product warranty to 10 years SolarWorld guarantees a maximum performance digression of 0.7% p.a. in the course of25yea rs,a significa nt a dd ed va lue corn pared to th e two-p h a s e wa rra nti es com mo n in the industry, along with our industry -first 10 year product warranty." Solar cells manufactured in U.S.A. or Germany. Modules assembled in U.S.A. 'in accordance with the applicable SolarWorld Limited Warranty at purchase. www.sc)larworld.com/warranty solarworld.com •SafeHlmlea. , -1 ranamaalax.lEcsooEa-zse • Ammonia rtsisd�, IK 6If 16 • Salt m ill aaamsim,, IFC fi1101 .ea,lo&cimpttuan C US MZ&,pedod'uimpttnon UL 1703 • em„a.,nnwu.a Umi C \ eaainGiiinamiio_ 0_/ DVE GS MADE IN UISA OFUS&PHORRTFDPams Sunmodule% Plus SW 285-300 MONO (5-busbar) PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC)' SW 285 SW 296 sw 295 SW 300 Maximum power P,,,, 285 Wp 290 Wp 295 Wp 300 Wp Open circuit voltage V. 39.7 V 39.9 V 40.0 V 40.1 V Maximum powerpoint voltage Vmm 31.3 V 31A V 31.5 V 31.6 V Short circuit current Iu 9.84A 9.97A 10.10A 10.23A Maximum powerpoint current I 9.20A 9.33A SIASA 9.57A Module efficiency nm 17.00 % 17.30 % 17.59 % 17.89 % °STC:1000W/m; 25'C, Ah1L5 PERFORMANCE AT 800 W/Mt, NOCT, AM 1.5 SW 285 SW 290 SW 295 sW 300' Maximum power Pm„ 213.1 Wp 217.1 Wp 220.5 Wp 224.1 Wp Open circuit voltage V. 36A V 36.6 V 363 V 36.9 V Maximum powerpoint voltage v, 28.7 V 28.8 V 28.9 V 313 V- Short circuit current Ix 7.96 A 8.06 A 837 A 6.27 A Maximum powerpoint current 1, 7.43 A 7.54 A 7.64 A 7.75 A Minor reduction in efficiency under partial load mndtions at 25 °C: at 200 W/m', 100%of the STC efficiency (1000 W/m) is achieved. 'Preliminary values• subject to change. COMPONENT MATERIALS IY 1060 W/W Celispermodule 60 Front Low -iron tempered glass B00 W/W with ARC (EN 12150) g 600 W/mz Monocrystalline Cell type 5-bulbar Frame Clearanodizedaluminom 400 W/W 6.17inx6.17in Celldimensions (156.75 x 156.75 mm) Weight 39.71bs (18.0 kg) 20 THERMAL CHARACTERISTICS ADDITIONAL DATA 100W1rrP rn2 _ NOCT 46'C Powersorting -0 Wp/+5 Wp modal-d;geM TC1. 0.04%/'C l-Box IP65 TCV_ -0.30%/°C Connector PV wire per UL4703 378 (961) with H4/UTx connectors 420 00 Modulefireperformance (UL1703)Typel 006.65)= 4x-1- Operatingtemp -40to+85'C 7.12 00.26(6.6) 080.85)1 PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION a 00.35(g) Maximum system voltage 5Cll/NEC 1000v Maximum reverse current 25 A o Number of byposs diodes 3 o Design loads' Two rail system 113 psf downward, 64 psf upward m 1 Design loads' Three rail system 178 psf downward, 64 psf upward Design loads' Edge mounting 178 psfdownward, 41 psf upward ' Please referto the Sunmodule installation instructions for the details associated with these load cases aaanll - Compatible with both "Top -Down' .0. fdo.35(9) T I •1 and'Bottom" mounting methods Grounding Locations: 11.32 (28750) LmI L -4locations along the length ofthe module in the extended flange. 39.40001) t 1.3o (33) I II All units provided are imperial.51 units provided in parentheses. SolarWorld AG reserves the rightto make specification changes without notice SW-01-751OU5160324 DESIGNED TO PERMIT-' CASTILLO ENGINEERING SERVICES, LLC 2925 W. STATE ROAD 434, SUITE 111 LONGWOOD, FL 32779 TEL: (407) 474-9181 ERMOCRATES E. CASTILLO - FL PE 52590 REVISIONS I PROJECT INSTALLER I F a'fNC45�JeE 19�� SQ °•J 9 No 5 i< •tr i S T E i PROJE v NOV 1 2 2 Z 0) M > W w� Z LL! Z J W J W U) F- w Uri m CO a W SHEET NAME DATA SHEET SHEET SIZE ANSI B 11r1 X 1711 SHEET NUMBER DS-01 - Castillo cpk Engineering DESIGNED TO PERMIT-` CASTILLO ENGINEERING SunnyBoy6.0115 Sunny Pay 7.0-US` Technical data Sunny Boy7.7-US'' SERVICES, LLC SUNNY F� ♦ BO� - - 208V 240v 208V __ __z4DV __ _ _ Input(DC) - -- - __ 2oa v_ ____ _ _ _ _24Dv _ _ - - -- conuze3gO _ ___ 2925W.SUTEE111 434, _ _ oy 1 % - -- -- _ - J Ry-1 n J ®� Max usable DC power SSOO W 6300 W 6900 W 7350 W 6950 W 8100 W LONGWOOD, FL 32779 • 0-g c� �N ` g 7 a 0-U S e -n 3.8- U S 5 c 0-U S 1 pal l�J% �I / (�F 6• S Maz.DCVoltage 600V TEL(407)474-91e7 Rated MPP Voltage range" . 220 "- 480 V 245. 480 V 270 - 480 V ERMOCRATES E. CAST LLO - FL PE 52590 r ------- '- MPPToperating 'voltage range .. 100:550.V .. REVISIONS j Min. DC voltage / start voltage 100 V / 125 V P Max operating input current per MPPi - - - - - DESCRIPTION DATE REV tit%3 " - - - - - - -- - - -_-- - Mks ortcir�uit current per MPPr 18 A Number of MPPTtracker/ string per MPPT tracker 3/1 44 t n Output (AC) AC nominal 5206 W 6006 W 6660 W 7000 W 6660 W 7680 W s power Max. AC apparent power 5200 VA 6000 VA 6660 VA 7000 VA 6660 VA 7680 VA rk t ' Nominal voltage / adjustable 208 V / •" 240 V / • 208 V / ! 240 V/ 0 208 V-/ • 240 V / • s AC voltage range 183 - 229 V 211 - 264 V 183 - 229 V 211 - 264 V 'grid 183 - 229 V 211- 264 V i AC,frequency 601iz/50Hz Max. output current 25.0A 25.0A 32.0A- 29.2A 32.0A 32.0A PROJECTINSTALLER (i "-_ I -C7 ` � � { Power factoi (cos W) 1 Output phases / line connections 1/2 '- Harmonic c4 % \y Efficiency 7 n M= efficiency' 97.2 % 97.6 % 07.1 %' 97.2 % ' ' • 97.1 %' 97.2 % • `j1111111 ` 1 CEC efficiency 96.5 % 97 % 96.5 % 96.5 % 96.5 % 96.5 %' \(,AST J� �r Protection devices disconnect device �°• • DC Myth Sea I � �G DC reverse poloriy protection • � f _ _ _ _ - Ground Fault monitoring / Grid monitoring • - AC .. �a 0 5 9 O short circuit protect on • = Allpole sensitive residual current monitoring tmW (RCMU) • _ f a sy Arc fault c_ircuit interruptei (AFCI) - • a 'z Protection class / oveivoltage category I / lV s LLJ General data STAT r`�_,� Dimensions _, /H/D)inmm(in)_ 535x730x198(21,1x28.5x7.8) Packaging Dimensions H D) in 800"x 300 31.5 ® 0 • � ,,; SPS (W / / mm (in) 600 x (23.6 x x 11.8) 0• R " L Weight 26 kg,(5714) Packaging weight 30 kg (66 Ib) . , S' / r Operating temperature range - 25'C ...+60'C , O N A�-� �� t WORLD S FIRST Noise emission(typical) 26dB(A) 30dB(A)' PROJECT NAME SECURE POWER SUPPLY �. ' Internal power consumption at night <5 W Ali - - Topology Transfonnedess Cooling concept Corrver7ion Fan 7 o ,; �� .,t. ;, Features Secure Power Supply • FJ N O U °' N z } Lo - - .. "Display 16 (2 x characters) • _ - .. w Q Interfaces: Ethernet MAN • / • 0 M • ` Sensor module / Extemal WIAN antenna 0/0 ?• Warranty 10 / 15 / 20 years •/o/o U) LL Value -Added Improvements ; ' Reduced Labor Unmatched Flexibility Trouble Free Servicing„Standard Certificates and approvals _ UL 1741, UL 1998, UL 1699111, IEEE1547, FCC Part 15 (Class A & BJ, CAN/CSA V22.2 107.1-1 - features o Optional features - Not available Data at nominaF conditions NOTE US inverters ship with gray lids, ' Preliminary, data, ul pending W ' ! World's first Secure Power Supply New Installation Assistant with SMA's proprietary OptT-p roem ' Two -port enclosure concept Type designation - 586.a15P-US-0O SB7.0.15P-US40 SB7.7-15P-US40 j)� Z now offers up to 2,000 W direct access via smoriphone Global Peak technology mitigates allows for simple, expedited. Z W • Full grid management capabilities minimizes time in the field shade with ease servicing L LI J J ensures a utility -compliant solution Integrated disconnect simplifies Multiple independent MPPTs Enhanced AFCI technology reduces For any market equipment stocking and speeds accommodate hundreds of false hipping While improving installation stringing possibilities sensrtiviy Mal al arts, greatly W CD W reducing unneeded service cans w SUNNY BOY M CO 3.0-US / 3.8-US / 5.0-US / 6.0-US / 7.0-US 7.7-US elf SAME NAME, NEW GAME Reduce costs across your entire residential business model The Sunny Boy 3.0-US through 7.7-US are once again raising the SHEET NAME The residential PV market is changing rapidly, and we understand that your bottom line matters more than ever. That's bar by offering improved performance, enhanced features, and most why we've designed a superior residential solution that will help you decrease costs throughout all stages of your importantly, an economical approach to residential solar. Your business DATA SHEET business operations. The Sunny Boy 3.0-US/3.8-US/5.0-US/6.0-US/7.0-US/7.7-US join the SMA lineup of field -proven model is a value chain. The new Sunny Boy -US series can help you stay solar technology backed by world's #1 service team, along with a wealth of improvements. Simple design, improved stocking and ordering, value driven sales support and streamlined installation are just some of the ways that SMA is working to help your business operate more efficiently. competitive in an increasingly price sensitive residential market by driving down costs across all of your business operations. SHEET SIZE ANSI B www.SMA-America.com - 1 1 tr X 17" SHEET NUMBER DS-02