Loading...
HomeMy WebLinkAboutPRE BUILDING PERMIT DOCUMENTMA Le 2431 SE Dixie Highway 34996 CONCEALED FASTENERS OR ATTACHMENTS Stuart,(772) 28 -0525 Phone: (772) 287-0525 ARE THE RESPONSIBILITY OFTF nail: mathersengineers@bellsouth.net ENGINEERING CONTRACTOROFAECORD License: EB 0004456 'ORATION ING PERMIT DOCUMENT ALL MANUFACTURES TABLES SHOWING September 10, 2018 U FACTORS AND SHGC COMPLIANCE �� WITH FBC ENERGY CODE MUST St. Lucie County Building Depa ON ALL DOORS AND WINDOWS 2300 Virginia Avenue, Fort PierccUfjLj14 itONSAMAPPROVED �O %, y Mr. Dave DeFerrari 12863 South Indian River Drive, Jensen Beach, FL 34957 After the Fact Re -roof Permit for Main Residence and Guest House Located at 12863 South Indian River Drive, Jensen Beach, FL 34957 presentative from Mathers Engineering Corporation visited the above referenced residence to observe the iously installed reroof. The following observations were made: • Dry -in nailing was verified by visual observation of the underside of the existing sheathing. Dry -in nails could be verified visually. Areas observed were made accessible through an attic access port in the garage. Dry -in was one layer of PolyGlass USA, Inc.'s Polystick Underlayment (Miami -Dade NOA #17-0614.22) was attached to the existing plywood sheathing • Extreme Metal Fabricators, LLC "5V Crimp" Metal Roof System was installed in 2010. Metal roof anchoring as per the attached Florida Product Approval (FL #17022.1) was spaced at approximately 12- inches O.C. both at panel's edge seams and mid -seams. Metal roof panels were anchored at 6 inches O.C. at roof outside edge and 12 inches in the field as per the requirements of the Florida Product Approval FL 17022.1. • Drip edge: Drip edge is 2" x 2" galvanized aluminum flashing. As a spot check, areas were lifted to inspect the flashing. The edge flashing and seam attachments appeared to be in compliance with the requirements of FL 17022.1. ring final observations, and except for minor ware, the observed metal roofing panels and underlayment seared in substantial conformance with the Florida Product Approval (FL #17022.1), the 2017 Florida ilding Code (61h edition), and standard engineering practices. HTATIONS: professional services have been performed, our findings obtained, and our opinions prepared in accordance i generally accepted engineering principles and practices. This company is not responsible for the elusions, opinions or recommendations made by others based on this data. The opinions submitted in this >rt are based upon data obtained from Visual Field Observations made on August 21, 2018. The scope of services does not include any items or components not visually observed or mentioned in this document nor ironmental assessment or investigation for the presence or absence of hazardous or toxic material in the soil, xndwater, or surface water within or beyond the site studied. No\\11 I I I1///�// proved by: \���`�PM-J=M=ATti�:/i/ \v�,•��GENSF `•��'P % ST. IL'CIE C"OiT�"Tl' BUZLDP;C PE 19658 �;N _ C_ dZEVIE�\ ED Foff c REVIEWED y DATE STATE OF ; �� ` PL�,�S *O P R bN T BE KEPT ON SOB liam J. Mathers, PLC R� p. w O;t J iIrSPLCTIO NVILL BE � +DE. ida License #19658�//'��`S;' OR10 �G\���� "` �� Copy /����S/ONA l \\\�\�