HomeMy WebLinkAboutDRAWING'
JOB: NESTE, 6201 SPRING LAKE TERR, FT PIERCE ,FL 34951150MPH EXP C
EDEN SCREEN. 772-216-6171 EDEN68@AOL.COM
Z�
;
.
1
i z 3 nz
�'
iM TAsI.S VS A BPS Tro?�V��
Z to 2-43 D"3
SIBS �?�Z
i
)(Z
-17
F
AS
In the event of a Conflict in member sizes shown on
the plans and the general notes, the contractor must
utilize the more stringent members 47requirements,
Engineer: Michael Tompson, P.E.
4—�r."40
.
Z.X3
i
EXTRUDED FASCIA IS ATTACD
3" C CHANNEL IS
D TO BLOCK STRUCTURE
ALUMINUM SCREEN DESIGNY INSULATED ROOF WITH # 0011' 6T0 6" FROM ENDS NDS 24"�O.C. &ITO 3" INSULATED ROOF WITH 6H#10/1" ER SIDE
.
FROM ENDS 24" O.C.
EXTRUDED GUTTER IS ATTACHED
3" INSULATED ROOF WITH 910 1" 6"
FROM ENDS 24" O.C.
ROOF IS ATTACHED TO FRONT WALL
WITH (4) #10 4" PER PANEL
2X3 FRONT WALL TOP PLATE
2X2 POST .046 OR GREATER
HINGE LOCATIONS
SCREEN DOOR FULL Z OR
DOOR JAM STANDARD DETAIL
0" to 36"
2 HINGE DOOR
EACH DOOR IS SCREWED INTO UPRIGHTS WITH #10 1" 6" FROM ENDS 24" O.0
KICK PLATE IS ATTACHED TO STRUCTURE
WITH 910 1" 6" FROM ENDS 18" O.C.
ALUMRR UMSCREENDESIGN.COM
ALUMEN UMSCREENDESIGN
@YAHOO.COM
PHONE: 407-734-1470
FAX: 407-734-1790
UPRIGHTS ARE ATTACHED WITH:
BLIND SCREWED WITH (3) 910 3",
CAPRI CLIPPED WITH (4) 910 1" PER CLIP
BLIND CLIPPED WITH (4) #10 1" PER CLIP
1X2 IS ATTACHED TO FRONT WALL
WITH #10 2" 6" FROM ENDS 24" O.C.
CHAIR RAIL IS ATTACHED TO UPRIGHTS
WITH EITHER:
BLIND SCREWED WITH (3) 910 3" OR,
CAPRI CLIPPED WITH (4) #10 1" PER CLIP OR
BLIND CLIPPED WITH (4) #10 1" PER CLIP
UPRIGHTS ARE ATTACHED WITH:
BLIND SCREWED WITH (3) #10 2" OR,
CAPRI CLIPPED WITH (4) #10 1" PER CLIP &
BLIND CLIPPED WITH (4) #10 1" PER CLIP
DESIGN STATEMENT
METAL IS .046 THICKNESS OR GREATER, ALLOY IS 6005-T5
ALL TAPCONS SHALL PROVIDE MINIMUM OF 1 1/8" CONCRETE EMBEDMENT DEPTH
" INSULATED ROOF IS ATTACHED TO
,LUMINUM STRUCTURE WITH 910 4"
11 vn nT If vi me 1)A If n r
SIDE WALL TOP PLATE
SCANNED
BY
St Lucie County
1X2 IS ATTACHED TO BLOCK STRUCTURE
WITH 2-1/4" X 1/4" TAPCONS 6" FROM
ENDS 24" O.C.
2X6 SIDE WALL UPRIGHTS
2" X 2" X 1/8" ANGLE IS ATTACHED TO
UPRIGHT W/ (2) #10 1" & INTO CONCRETE
W/ 2-1/4" X 1/4" TAPCON
2X3 CHAIR RAIL
1X2 IS ATTACHED TO CONCRETE
WITH 2-1/4" X 1/4" TAPCONS
(5" X 1/4" IF THRU PAVERS)
6" FROM ENDS 24" O.C.
THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2017 (6TH EDITION)
FLORIDA BUILDING CODE FOR OPEN AND SEMI -OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND SPEEDS OF 150 MPH
(FOR 3 SECOND GUSTS) NOMINAL SPEED 117 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY 1.
CONTRACTOR SHALL FIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL PURCHASE, FABRICATION AND CONSTRUCTION
CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SHOULD SITE CONDITIONS DIFFER FROM CONSTRUCTION PLANS
MICHAEL THO
4401 VINELA.ND LOAD.
SUITE A6
ORLANDO,, FL 32811
FJ.* 47509
-• CA#30930
ALUMINUM SCREEN DESIGN
SCANNED
BY
81 Lucle County
d 4 1:MME-1 l I i—I I I —I
G
CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING:
�- VAPOR & TERMITE PROTECTION (IF REQUIRED)
CONCRETE SHALL BE A MINIMUM OF 3000 PSI
FOR COVERED STRUCTURES, CONTRACTOR SHALL
SECURE COLUMN BASE DIRECTLY TO THICKENED EDGE
ALUMINUMSCREENDESIGN.COM MICHAEL, THOMPSON
ALUNIINUMSCREENDESIGN 4401 VINELAND LOAD
@YAHOO.COM ' SUITE A6
ORLA , O, FL 32811
PHONE: 407-734-1470
P.E. # 47509
FAX: 407-734-1790
CA#30930