Loading...
HomeMy WebLinkAboutDEPARTMENT OF HEALTH SEWAGE TREATMENT AND DISPOSAL SYSTEM 2-1-19►E- PERMIT #:56-SF-1863486 APPLICATION #:AP1355466 STATE OF FLORIDA •; ,j y; r t DEPARTMENT OF HEALTH DATE PAID: ONSITE SEWAGE TREATMENT AND DISPOSAL FEE PAID: SYSTEM ,ti iy RECEIPT # C "� DOCUMENT #: PR1127814 CONSTIIIIRUCTION PERMIT FOR: OSTDS Repair WANNER APPLICANT: Keith Isemia BY PROPERTY ADDRESS: 6001 Myrtle Dr Fort Pierce, FL 34982 51 Lucie County LOT: 25 BLOCK: 66 SUBDIVISION: Indian River Estates PROP RTY ID #: 3402-609-0523-000-4 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYST�jIM MUST BE CONSTRUCTED IN ACCORDANCE WITH ' SPECIFICATIONS AND STANDARDS OF SECTION 381.Ob65, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHIC SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE(� OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYS T [ A [ N [ K [ D [ R [ A T I C N' F L I E: E Bi L D F: 0 T H E IS. R DATE DH 41 DESIGN AND SPECIFICATIONS 900 ] GALLONS / GPD Seotic New - • CAPACITY 0 j GALLONS / GPD CAPACITY 0 ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ ] 200 ] SQUARE FEET Drainfield New SYSTEM 0 ] SQUARE FEET SYSTEM SYSTEM: [x] STANDARD [ ] FILLED [] MOUND IGURATION: [ ] TRENCH [X].BED [ ] FM TION OF BENCHMARK: Orange spot on SW corner of screen enclosure ATION OF PROPOSED SYSTEM SITE [ 2.00 ][ INCHES FT ](ABOVE BELOW BENCHMARK/REFERENCE POINT DM OF DRAINFIELD TO BE [ 22.001 INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT REQUIRED: [ 0.001 INCHES EXCAVATION REQUIRED: [ 45.001 INCHES system is sized for 2 bedrooms with a maximum occupancy of 4 persons (2 per bedroom), for a total estimated flow of 9pd• arming Lift Dosing. Is must be certified as suitable for distributing sewage effluent. licensed contractor installing the system is responsible for installing the minimum category of tank in accordance with E-6.013(3)(0, FAC. Required drainfield area based on rule 64E-6.015(6)(c)2. I a new drainfield to achieve Drainfield size requirement. CATIONS BY: Dianna S May TITLE: Environmental Specialist I D BY: !'% TITLE: Environmental Specialist I - Dianna S May SUED: 08/01/2018 EXPIRATION DATE 08/09 (Obsoletes all previous editions which may not be used) rated: 64E-6.003, PAC St. Lucie CHD �10/30/2018 P'ge 1 of 3 iSTATE' OF FLORIDA DEPARTMENT OF HEALTH u'_a`! ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM ':► �% CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLI T: Keith Isernia AGENT:I Benjamin Drew "s Plumbing & Drain Services PROPEF TY ADDRESS- 6001 Myrtle Dr Fort Pierce, FL 34982 LOT: �� BLOCK: 66 Indian River Estates ID#: 3402-609-0523-000-4 APPLICATION # : A-;-' ! ' -' PERMIT #:56-SF-1863486 DOCUMENT #:F11204028 DATE PAID:07/17/2018 FEE , PAID:315.00 RECEIPT #:56-PID-3620615 CHECKED [XI ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. I TANK INSTALLATION [ ] [01] TANK SIZE [1] 900.00 [21 [ ] [021 TANK MATERIAL Polyethylene ' [ ] [031 OUTLET DEVICE [ J (04] MULTI —CHAMBERED [ Y N ] [ ] [051 OUTLET FILTER Polylok PL-68 [ ] [061 LEGEND 1. 70-156-90DC3 2. [ ] 1071 WATERTIGHT [ ] [08] LEVEL [ ] R [091 DEPTH TO LID DRAINFIELD INSTALLATION [ ] [101 AREA [1] 525 [21 SQFT [ ] [11] DISTRIBUTION BOX HEADER X [ J [121 NUMBER OF DRAINLINES 1. 5.00 2. [ ] [131 DRAINLINE SEPARATION [ ] [141 DRAINLINE SLOPE [ ] [151 DEPTH OF COVER [ ] [161 ELEVATION [ ABOVE / BEIAW IBM 22.00 [ ] [171 SYSTEM LOCATION [ ] 118] DOSING PUMPS [ ] [19] AGGREGATE SIZE [ ] [201 AGGREGATE EXCESSIVE FINES [ J [211 AGGREGATE DEPTH FILL / EXCAVATION MATERIAL [ ] (22] £ILL AMOUNT [ ] (231 FILL TEXTURE [ ] (24] EXCAVATION DEPTH [ ] [251 AREA REPLACED [ ] [26] REPLACEMENT MATERIAL 'omme ts: Comments are on page 2, SETBACKS [271 SURFACE WATER FT [28] DITCHES FT [291 PRIVATE WELLS 78 FT [301 PUBLIC WELLS FT [311 IRRIGATION WELLS FT (321 POTABLE WATER 45 FT (33] BUILDING FOUNDATIONS•• 5 FT (341 PROPERTY LINES 8 FT FT [35J OTHER FILLED / MOUND SYSTEM [361 DRAINFIELD COVER [37] SHOULDERS 1381 SLOPES [391 STABILIZATION ADDITIONAL INFORMATION [ ] [40] UNOBSTRUCTED AREA [ ] [411 STORMWATER RUNOFF [ ] [421 ALARMS [ ] [431 MAINTENANCE AGREEMENT [ ] (441 BUILDING AREA [ ] [45] LOCATION CONFORMS WITH SITE PLAN [ ] [46] FINAL SITE GRADING [ ] (471 CONTRACTOR (Benjamin Drew s Plumbing [ ] [48] OTHER INFILTRATOR ARC 24 ABANDONMENT [ ] [ 4 9 ] TANK PUMPED 08/22/2018 [ ] [50] TANK CRUSHED & FILLED 08/22/2018 CONSTRUCTION FINAL YSTEM [ APPROVED DISAPPROVED ] ° [ APPROVED / DISAPPROVED ]: �St. Lucie cHD Environmental Specialist 1 Dia/nn�6`VMay (Florida Department of Health �i�9t^^—� St. LUCIe CHD Environmental Specialist 1 Dia a S May (Florida Department of Health DATE: 08/22/2018 DATE: 08/2?J�2018 (Explanation o£ Violations on following page) 1 DH 4016, Incorporated: III 08109 (Obsoletes all previous editions which.may not be used) 64E-6.003, FAC EN Database v I.0.1 AP1.155d66 1 page 2 of 3 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Comment APPLICATION PERMIT #:56-SF-1863486 DOCUMENT # : FI 1204028 DATE PAID:07/17/2018 FEE PAID :31 5.00 RECEIPT #:56-PID-3620615 The system is sized for 2 bedrooms with a maximum occupancy of 4 persons (2 per bedroom), for a total estimated flow of 200 ]pd- Vew ST�'Ld DF installed 5x7 chambers long. No violations observed, system ok to cover. Contractor notified by phone. Emailed to DH 4011i6, 08/09 (Obsoletes all previous editions which may not be used) Incor grated: 69E-6.003, FAC cIC'Ii:G3d$G EI•I Datalmse v 1.0.1 API. 55d66 Page 2 of 3 (-"A q -0 aj i i DOCUMENT H : PR1127814 b) bottom of the tank shall be opened or ruptured, or the entire tank collapsed so as to prevent the tank from retaining water, and( ) The tank shall be filled with clean sand or other suitable material, and completely covered with soil.Have the system a n d J( inspected by the health department after it has been pumped and ruptured but before it is filled with sand and covered. I