HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FL O IDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Flo'ida Department of Business and Professional Regulation - Residential Performance Method
Project
Name: ISERNIA ADDITION Builder Name:
Copy
6001 MYRTLE DRIVE Permit Office: SEO TY
City, Sta
eStreet:
, Zip: FT. PIERCE, FL, Permit Number..
Owner:
KEITH ISERNIA Jurisdiction:
Design L'
cation: FL, Fort Pierce County: St: Lucie (Florida Climate Zone 2 )
1. New co Istruction or existing Addition
9. Wall Types (320.0 sgft.) Insulation Area
2. Single f mily or multiple family Single-family
11
a. Concrete Block - Ext Insul, Exterior R=4.1 320.00 ft2
b. N/A
R= ft2
3. Numbei of units, if multiple family 1
c. N/A R= ft2
4. Numbe of Bedrooms(Bedrms In Addition) 1(1)
d. N/A R= ft2
5. Is this `worst case? No
10. Ceiling Types (290.0 sgft.) Insulation Area
Ined
a. Under Attic (Vented) R=30.0 290.00 ft2
6. Conditi floor area above grade (ft2) 290
b. N/A R= ft2
Conditi ned floor area below 0
_ z
c. N/Aucts R
grade (ft2)
Is(40.0
11 R ft2
7. Windo sgft.) Description Area
a. Sup: Attic, Ret: Attic, A .� ttic 6 58
�����
a. U-Flctor: Dbl, U=0.65 40.00 ft2
BY
SH SHGC=0.25
b. U-Fi�tor: N/A ft2
12. Cooling systemst �UCOe®�JIf9d� /hr Efficiency
SH C:
a. Central Unit 8.0 SEER:14.00
C. U-F, ctor: N/A ft2
SHGC:
d. U-Falctor: N/A
13. Heating systems kBtu/hr Efficiency
ft2
SHdQ:
a. Electric Strip Heat 27.0 COP:1.00
Area W.F" ighted Average Overhang Depth: 2.000 ft.
Area WlIbighted Average SHGC: 0.250
14. Hot water systems - None required
a
8. Floor Types (290.0 sgft.) Insulation Area
EFa 0.000
a. Slab ;On -Grade Edge Insulation R=0.0 290.00 ft2
b. Conservation features
b. N/A R= ft2
c. N/A i R= ft2
I
15. Credits CF, Pstat
Glass/F'I
or Area: 0.138 Total Proposed Modified Loads: 15.09 PASS
j
Total Baseline Loads: 15.58
I hereby
ertify that the plans and specifications covered by
Review of the plans and ST
this calc,
lation are in compliance with the Florida Energy
O�ZHE
specifications covered by this _ Off,
Code.
calculation indicates compliance ya„ ' _ -
- ````�•� "�
D Y:
with the Florida Energy Code. rn�„��: "`
PREP A
Before construction is completed r
DATE:
�_
this building will be inspected for y
compliance with Section 553.908 * "'
I hereby ,
ertify that this bui ng, as designed, is in compliance
Florida Statutes.
with the
lorida Energy de.�
COD we
OWNE
AGENT: t
BUILDING OFFICIAL:
Z
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certi4d factory -sealed in accordance with R403.3.2.1.
- Comp�,ance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelo i leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2)
RECEIVEp _
'FEB 1L 2019
2/8/20 9 9:13 AM EnergyGauge@) USA Section R405.4.1 Compliant Software � �0f1��r� age 1 of 4
II
GnQnn PA '-'n17
IKIDI IT CI IMMAPV rWI=f_I(I ICT RFPf)PT
1'
- PROJECT
Title: 1;
Building 'Type:
Owner Name:
# of Unib li
Builder Name:
Permit O ice:
Jurisdicti In:
Family Type:
New/Existing:
Comment:
ISERNIA ADDITION
User
KEITH ISERNIA
1
ST. LUCIE COUNTY
Single-family
Addition
Bedrooms: 1
Conditioned Area: 290
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 6001 MYRTLE DRIVE
County: St. Lucie
City, State, Zip: FT. PIERCE,
FL,
CLIMATE
II
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
I
Blockl
290 2320
SPACES
NumbipIr
Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled Heated
1
ADDITION
290 2320 Yes 1
1
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio ADDITION 72 ft 0
290 ftz
---_ 1 0 0
ROOF
/ I
�/
#
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt Emitt Deck Pitch
Tested Tested Insul. (deg)
1
Hip Composition shingles 314 ftz 0 ftZ Medium
0.6
No 0.9 No 0 22.6
ATTIC
V I,
#
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
I!
1
Full attic
Vented 150 290
ftz
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
ADDITION 30 Blown
290 ftZ 0.11 Wood
I
2/8/20119 9:13 AM
III
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 2 of 4
I
PnQnn PA L,.?n 17 IAIPI IT CI IRfiRI ('-WI=r-LCI ICT RFPC)RT
III
WALLS
Adjacent
Space Cavity Width Height Sheathing Framing Solar
Below
1
2
3
N
N
N
Exterior Concrete Block - Ext InsLADDITION 4.0999 10 8 80.0 ftz 0 0 0.6
Exterior Concrete Block - Ext InsLADDITION 4.0999 20 8 160.0 ftz 0 0 0.6
Exterior Concrete Block - Ext InsLADDITION 4.0999 10 8 80.0 ftZ 0 0 0.6
0
0
0
DOORS
111 #
Ornt Door Type
Space Storms U-Value Width Height
Ft In Ft In
Area
1
N Insulated
ADDITION None .46 3 6 8
20 ftZ
WINDOWS
Orientation shown is the entered, Proposed orientation.
V #
Wall
Ornt ID Frame Panes
Overhang
NFRC U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
I'I
N 2 Metal Low-E Double Yes 0.65 0.25 N 20.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds
N 3 Metal Low-E Double Yes 0.65 0.25 N 20.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds
None
None
INFILTRATION
# Scli pe
Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000356 270.7 14.86 27.94 .2578 7
III
HEATING SYSTEM
#
System Type
Subtype Efficiency Capacity Block
Ducts
I'
1
Electric Strip Heat/Existing/co
None COPA 27 kBtu/hr 1
sys#1
COOLING SYSTEM
I,
#
System Type
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/Existing/confirme
None SEER: 14 28 kBtu/hr 840 cfm 0.75 1
sys#1
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume FEF
II
ftz
DUCTS
#
--- Supply ---
Location R-Value Area
--- Return -- Air CFM 25 CFM25 HVAC #
Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1
Attic 6 58 ftz
Attic 15 ftz Default Leakage Attic (Default) (Default)
1 1
2/8/20119 9:13 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4
INPI IT Al1MMARY CI-IFCKI IST REPORT
1�1
FORM R40.5-2017
I
TEMPERATURES
Program
able Thermostat: Y
Ceiling Fans:
Cooling
Heating
[ Jan Feb
f X Jan Feb
Mar
Xj Mar
Apr
Apr
f
May
j May
[X] Jun
r j Jun
[X] Jul
[ j Jul
[ ]Aug
rj Aug
Sep
JXJ Sep
[ Oct
[ ]Oct
[ ] Nov
[X] Nov
Dec
X Dec
Ventin
[[ Jan Feb
[rX Mar
rxl
A r
r
Ma
[ ] Jun
[ j Jul
[ ] Au
Se
[X] Oct
[X] Nov
r Dec
Thermosta
Schedule: HERS 2006 Reference
Hours
Schedule
pe
1
2
3
4
5
6
7
8
9
10
11
12
Cooling
i) AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (
H) AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
II)
78
78
78
78
78
78
78
78
78
78
78
78
Heating
AM
66
66
66
66
66
68
68
68
68
68
68
68
f PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating i
EH) AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
M
ss Type
Area
Thickness
Furniture Fraction
Space
D
I#ault 8 Ibs/s .ft.
0 ft2
O ft
0.3
ADDITION
Name:
Rating Compant:
D.
2/8/2019 9:13 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4
2017 - IR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
i
ProjeFlt Name: ISERNIA ADDITION Builder Name:
Street: 6001 MYRTLE DRIVE Permit Office: ST. LUCIE COUNTY
City, tate, Zip: FT. PIERCE, FL, Permit Number:
U
Own r: KEITH ISERNIA Jurisdiction:
w
Desi '� Location: FL, Fort Pierce
I
U
COM
i
ONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
require iients
Breaks or joints in the air barrier shall be sealed.
Ceiling/
ttic
The air barrier in an dropped ceiling/soffit /soffit shall be aligned with
y PP g g
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windo skylights
The space between window/doorjambs and framing, and
and do Ilrs
skylights and framing shall be sealed.
Rim joi 'ts
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(includi
` g
insulation.
maintain permanent contact with the underside of
above-
arage
subfloor decking, or floor framing cavity insulation
and ca
tilevered
shall be permitted to be in contact with the top side
floors)
I
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
j
members.
Crawl tace walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts
penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrov
cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garag
separation
Air sealing shall be provided between the garage and conditioned spac
Bs.
Reces
ed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumd
g and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind n M ping i1nd wiring-
Show/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on ext nor wall
tubs shall separate them from the showers. and tubs.
be insulated.
Electnpal/phone
box o
The air barrier shall be installed behind electrical or communication
exteri "I
walls
boxes or air -sealed boxes shall be installed.
HVAC`iregister
boots
HVAC register boots that penetrate building thermal envelope shall
li
be sealed to the sub -floor or drywall.
Con tiled
When required to be sealed, concealed fire sprinklers shall only be
sprink ers
sealed in a manner that is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be used to fill voids
between fire sp-r-in kler cover plates and walls or ceilings,
2/8/20 919:`
13 AM GLdIVII VI IVy wG11A .1'd'1 uEnergyGaug ® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home.
1. ew home or, addition
i
2. ingle-family or multiple -family -
3. o*
of units (if multiple -family)
4. qumber of bedrooms
1. Addition 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family b) Return ducts R 6.0
c) AHU location Attic/Attic
3. 1
4. 1
5.'I's
this a worst case? (yes/no)
5.
No
6.
i
t✓onditioned floor area (sq. ft.)
6.
290
7.
Windows, type and area
a) U-factor:(weighted average)
7a.
0.650
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
c) Area
7c.
40.0
8. Skylights
I a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. 1Floor type, insulation level:
j a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
1(
Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
13. Cooling system: Capacity 28.0
a) Split system SEER
b) Single package SEER
c) Ground/water source SEER/COP
d) Room unit/PTAC EER
e) Other 14.0
14. Heating system: Capacity 27.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%
g) Other
10B1.
10B2.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
Yes
11 a. 30.0
b) Cross ventilation
No
11 b.
c) Whole house fan
No
11 c.
d) Multizone cooling credit
11 d. No
e) Multizone heating credit
0 Programmable thermostat
Yes
required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
artify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
ring features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
play card will be completed base on installed code compliant features.
ilder Signature: Date:
dress of New Home: 6001 MYRTLE DRIVE City/FL Zip: FT. PIERCE, FL.
9:13:31 AM EnergyGauge@ USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
® Pro ect SummaryJob:
- rightsoft Entire House Date:
By:
QUICK CALCS, INC.
317 ST. UCIE LANE. FORT PIERCE. FL34946 Phone: 772-466-6799 Email: QUICKCALCSDAOL.COM
For:
Notes:
ISERNIAADDITION
6001 MYRTLE DRIVE, FT. PIERCE, FL
Weather:
Winter Design Conditions
Outside db 42 OF
Inside db 70 OF
Design TD 28 OF
Heating Summary
Structure
18133
Btuh
Ducts
3367
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
21499
Btuh
Infiltration
Method
Construction quality
Fireplaces
Fort Pierce, FL, US
Simplified
Average
0
Heatingg Coolingg
Area (ftz) 1196 1196
Wlume (fl3) 10764 10764
Air changes/hour 0.45 0.23
Equiv AVF (cfm) 81 41
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating Input
Heating output
Temperature rise
Actual airflow
Air flow factor
Static pressure
Space thermostat
Calculations
100 EFF
6.4 kW
21953 BFuh
400 cfm
0.019 cfm/Btuh
0.50 in H2O
SCANNED
BY
St Lucie County
Summer Design Conditions
Outside db
90
OF
Inside db
75
OF
Design TD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
grAb
Sensible Cooling Equipment Load
Sizing
Structure
18188
Btuh
Ducts
4598
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data
n
Rate/swingg multipplier
Equipmentsensible load
0.95
21647
Btuh
Latent Cooling Equipment Load Sizing
Structure
1724
Btuh
Ducts
1307
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
3031
Btuh
Equipment Total Load (Sen+Lat)
Req. total 0.70 SHR
24678
2.6
Btuh
ton
capacity at
Cooling Equipment Summary
Make Rheem
Trade EXISTING
Cond RAPC-030JAZ
Coil
AHRI ref
Efficiency 11.5 EER, 14 SEER
Sensible cooling
19600
Btuh
Latentcooling
8400
Btuh
Total cooling
28000
Btuh
Actual airflow
933
cfm
Air flow factor
0.041
cfm/Btuh
Static pressure
0.50
in H2O
Load sensible heat ratio
0.88
ACCAto meet all requirements of Manual J 8th Ed.
wrightsoft® PigN_Smote®Uriversal201818.0.16RSU08101
1Doamerts%WrightsoftWACVSERNIAADDMON.n{p Calc=MJ8 rrordDoor faces: NE
201 0—Feb-08 09:11.40
Page 1
-�+irightsoft, Right-M Worksheet ote:
Entire House
QUICK CALCS, INC.
317 ST. UCIE LANE, FORT PIERCE, FL34946 Phone:772-466-6799 Email: QUICKCALCS@AOL.COM
1
2
3
4
5
Room
cornname
sed wall
oom height
oom dimensions
area
Entire House
144.0 ft
9.0 ft
1196.0 ft=
NEW BEDROOM
28.0 ft
9.0 ft heaV000l
1.0 x 160.0 ft
160.0 fF
y
Construction
number
U-value
(Btuh/ft;°F)
Or
HTM
(Biuhtfl
Area (ft?)
or perimeter (ft)
Load
(Btuh)
Area (fF)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
I Cool
63
11
--
_
I _
I--v
I
�--G
it-
i
12B-_Osw-.------ -
13AAo s
1A-c1om
IA-clom
4A5-2ob
-11 DO ---- - - -
13A4ocs
4A5 lob
11D0 _-._ _-
13AAocs
IA-clom
IA-c1om -_ - ..___.
I3A
-IA-Glom---.--
1613-30ad-__
__ _- -_-
--- 0.097
0.143
1.270
1.270
0.560
---0390
0.143
0.560
-.---0.390
0.143
1.270
__-- 1.2-
0.143
_-_1.270
0.032
_ne_
ne
ne
ne
ne
_ ne_
se
se
_se-
sw
sw
sw
rnv
._nw_
.
_._.2.72
4.00
35.56
35.56
15.68
_ 10.92
4.00
15.68
_-JO.92
4.00
35.56
-_35,56
4.00
-35.56
-0.90
_- 2:34.
2.19
70.43
70.43
33.75
- 10.34
2.19
25.15
---10.34_
2.19
53.01
- 57.75
2.19
_-70.43:
1,60,
'0.
----90-
324
30
20
20
- -21
234
20
__-
__21_
414
20
_ 41
234
-___ 40.
_- _ 1196
----
-- --_90-
233
0
0
0
- - 21
193
10
_ 21.
353
10
_ _ _ 15
194
_-___ 0.
__ __ _ 1196
-- 244_
933
1067
711
314
--- 229
773
314
-_-229
1414
711
,__1451_
777
----1422
_ 1072
---210
510
2113
1409
675
-- 217
422
503
- .--217
773
1060
_ -2356
424
-_-2817
_ 1914
- 90.
0
0
0
20
- - 0
162
20
..__- . --0
0
0
--_ __-0
0
_.__-____0
_ 160
---- 90
-20
0
0
0
-- -- 0
142
10
----0
0
0
_ - - 0
0
----_0
_ 160
---_ 244.
-80
0
0
314
---- 5
569
314
-,_-0
0
0
-___ _ 0
0
--_-_0
____
-44
0
0
675
- - -0
311
503
0
0
-------0
0
- ___-0.
- 256
_ - 143,
--.
- __
--
---
--
-
-
---
6
li c) AED exarsion
118881
57
j1 Envelope lossigain
15649
17508
2279
1969
12
i
a) Infiltration
b) Room ventilation
2484
0
680
0
483
0
132
0
13
Internal gains Ooorpants@ 230
Applianoesrother
0
0
0
0
0
0
Subtotal (lines 6 to 13)
18133
18188
2762
2101
14
15
i
Less extemalload
Lesstransfer
Redistribution
Subtotal
Ductloads
19%
25%
0
0
0
18133
3367
0
0
0
18188
4598
19%
25%
0
0
0
2762
513
0
0
0
2101
531
Total room load
Air required (dm)
21499
400 1
22786
933
3275
61
2632
108
Calculations
�- wrigF�tsoTt®
Right-Suite®Uriversal 2018 18.0.16 RSU08101
1Doamerts\WrightsoftHVACVSERNIAADDITION.rup Calc=MJ8 Front Door faces: NE
of Manual J 8th Ed.
2019-Feb-08 09:11.40
Page 1
Irightsoft, Right-J® Worksheet Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST. UCIE LANE, FORT PIERCE, FL34946 Phone:772-466-6799 Email: QUICKCALCS@AOL.COM
1
cornname
NEW BATH
LAUND.
2
v✓all
14.0 ft
4.0 ft
3
oom height
9.0 ft heat/000l
9.0 ft heaUcooi
4
5
oom dimensions
Room area
6.0 x 8.0 ft
48.0 ft2
4.0 x 8.0 ft
32.0 T
d
y
Construction
U-value
Or
HTM
Area (ftz)
Load
Area (ft�
Load
number
(BtuhffL'F)
(Btuh/ft)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W
- -
12B Osw - -- -
13A-4ocs
- - -0.097
0.143
-ne
ne
- 2.72
4.00
_ _ _ 2.34
2.19
- 3
0
- -0
0
--Q
0
0
0
0
- 0
0
-- - - 0.
0
1A-clom
1.270
ne
35.56
70A3
0
0
0
0
0
0
0
0
1A-clom
1.270
ne
35.56
70A3
0
0
0
0
0
0
0
0
11
4A5-2ob
0.560
ne
15.68
33.75
0
0
0
0
0
0
0
0
_---_11D0---
ne_
10.92
10.34
0
0
--_----
13A-4ocs
_-- _0.390
0.143
_
se
__
4.00
2.19
-
72
___--
51
__-- _ __-0.
264
--
112
0
0
0.
0
4A5-2ob
0.560
se
15.68
25.15
0
0
0
0
0
0
0
0
,11D0--_-__._-
--_- 0.390
-_se_
__ JO.92
_- 10.34_
-____.21
-_. 21_
229
217
_-_---
-_- ._ _ 0
_�.•_- - _
WI
13A-46cs
1A�Iom
0.143
1.270
sw
sw
4.00
35.56
2.19
53.01
54
0
-- _
54
0
216
0
_-_
116
0
-0
38
0
-- -_--0
36
0
144
0
79
0
I--G
16-1om _ _-_--- -
-- 1.270
35,56
57.75,
0.
4.
0
P
13A-4ocs
__
0.143
._sw
riw
-_._-
4.00
-. _
2.19
.-__ _ _
0
_-_.__-
0
__
0
- --.
0
. -.-- ____0
0
0
0
0
IA-clom.- _-_.. ___ _.
_____ 1.270
_ riw.
--_35.56
___ -70.43.
- _ _ _ _0
.___ _ ._ ___ 0...____-.
-.0.
___ __ -0
__ _. ---0
__ ____-_0
_ ___ _ - 0
_ _ . _ _._._ 0.
-
-
16B 30ad - -
1 60
48
A8
43
n
32
32
29
--
- --0A32
--_
- ----- -
_ 27B
. -
-_ 0.00
- - -
48
-
- - _ 14
--
_ - - -368
- -
_-- - 0
-_.-
---- --
4
- - -
-- -51
6'
, c) AED
exarsion
---
-- ------
---- -- --
-16
----- ----
-
-------
--- ----
- -- -
---- -----
------
-- -
-------- -
--- - -4
Envelope loss/gain
1080
5081
284
126
12
a) Infiltration
11 b) Room ventilation
242
0
66
0
69
0
19
0
13
Internal gains Oocupants@ 230
Applianoes/other
0
0
0
0
0
0
Subtotal (lines 6 to 13)
1322
574
353
145
14
15
Less extemalload
Less transfer
Redistribution
Subtotal
Duct loads
19%
25%
0
0
0
1322
245
0
0
0
574
145
19%
25%
0
0
0
353
65
0
0
0
145
37
Total room load
Air required (cfm)
1567
29
719
29
418
8
182
7
Of
-rk- wrwotvtsoft-
Right-SuteOUniversal 201818.0.16 RSU08101
1Doamerts\WrightsoftWACUSERNIAADDITION.rup CaIc=MJ8 Front Door faces: NE
2019-Feb-08 09:11.40
Page 2
i II
- Irightsofte Right-J® Worksheet Job:
Enure House Date:
By:
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-466-6799 Email: QUICKCALCS@4OL.COM
1
2
3
4
5
oom name
wall
�o-omm height
oodimensions
cornarea
EXISTING HOUSE
98.0 ft
9.0 ft heatcool
36.0 x 26.0 ft
936.0 1t'
CLST.
0 It
9.0 ft heat/cool
5.0 x 4.0 ft
20.0 ft2
i
y
Construction
number
U-value
(Btuhtft;°F)
Or
HTM
(BWW)
Area (it)
or perimeter (ft)
Load
(Btuh)
Area (ff)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
11
-JI
----------
13A-flocs
1A-c1om
1A-c1om
4A5-2ob
13A-4ocs
4A5-2ob
13A•4ocs
1Ac1om
1A-dom __- _.---•--
13A-0ocs
-1A-c1om---.---.
1613_30ad
22A-tp1__. __- ---
-- - --- -- -- - ---
- - -- - - -
----
0.143
1.270
1270
0.560
0.143
0.560
- 0.390
0.143
1.270
----1.270
0.143
-- -1.270
-_ 0.032
_-- 0.989
- - - - - - -
- ---
-----
_ne_
ne
ne
ne
ne
se
se
_w-
sw
sw
, sw
nw
-nw_
__ _
_
---
--
__- 2.72
4.00
35.56
35.56
15.68
- 10.92
4.00
15.68
- 10.92
4.00
35.56
- 35.56
4.00
-_-_35.56
0:90
-_27.69
------
-- - -
_-_2.34:
2.19
70.43
70A3
33.75
-1Q-
2.19
25.15
10.34.
2.19
53.01
- 57.75
2.19
.-._7.0.43
1.60
- _0.00:
-- - ---
- -
-----___0
324
30
20
0
---21
0
0
-° --0
324
20
----- 41
234
_ 936-
_ ._ ---936.
--------
- ----
_ __0
253
0
0
0
----�1--__-
0
0
-- _ __
263
10
- ---- - 15-
194
936
_. _ 98.
-- ------
- - -
_- 0•
-
l-- -
1067
711
0
229
Q
0
-_..0.
1054
711
-1451-
777
- 839
- 2714-
-- - ----
-- - - -
-----_0
554
2113
1409
0
----217
0
0
---- 0
576
1060
- ---- _2356
424
_ 1498
--- -- --0
- - ---
---- -
=__- __-0
0
0
0
0
--0-----0---4----0
0
0
- - �.
0
0
----- 0
0
_ 20
_-_.. 20
-- - ---- -
- - -
_.-_
0
0
0
0
6
0
-._-_ --0,---
0
0
__------_ 0
0
20
----- --p
- -- ---
- -
----Q
0
0
0
0
0
0
-0
0
0
_--r- - 0
0
---- ---_A-
0
0
0
0
6
0
0
0
--- -- - 0-
0
_ 32
- - -- --0
-- - -- --
-
_.---11D0--------0.390_ne
1.
_ _
.,-G
-F.._
it-- -- --
- ...
I
_--_ 18
-• -- - �-
------ ---
-- -
-
-
- - -
--- -
-
--------
-----
-
-
-
- - -- -
--
- -
-----
-
6
I;I c) AED excursion
1851
1
�r Enwlope loss/gain
1 11988
148741
118
31
12
a) Infiltration
b) Room ventilation
1691
0
463
0
0
0
0
0
13
Internal gains: Occupants@ 230
Appliances/other
0
0
0
0
0
0
Subtotal (lines 6to 13)
13679
15337
18
31
14
15
Less extemalload
Lesstransfer
Redistribution
Subtotal
Dudloads
19%
25%
0
0
0
13679
2540
0
0
0
15337
3877
19%
25 0
0
0
0
18
3
0
0
0
31
8
Total room load
Airrequired (dm)
1
1
16218
3011
19214
7871
21
01
39
2
/ACCA to meet al I rec
-�'I't' wrFigF�tsoft�
Right-SuiteO Universal 201818.0.16 RSU08101
\Doamentss\WrightsoftHVACVSERNIAADDITION.rup Calc=MJ8 Front Door faces: NE
2019-Feb-08 09:11 A0
Page 3
® Duct System Summary Job:
- rightsoft y ry Date:
Entire House By:
QUICK CALCS, INC.
317 ST.'� UCIE LANE, FORT PIERCE, FL34946 Phone:772-466-6799 Email: QUICKCALCS@40L.COM
For. ISERNIAADDITION
6001 MYRTLE DRIVE, FT. PIERCE, FL
Exterrn�al static pressure
Pressure losses
Avail 'ble static pressure
Supp y / return available pressure
Lowekfriction rate
Ac"I airflow
Total letfective length (TEL)
Heating
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.456
in/100ft
400
cfm
110 ft
Cooling
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.456
in/1 00ft
933
cfm
Design
Htg
Clg
Design
Diam
H x W
Duct
Actual
Ftg.Egv
Name
(Btuh)
(cfm)
(dim)
FR
(in)
(in)
Mat
Ln (ft)
Ln (ft)
Trunk
CLS f�
c 39
0
2
0.475
4.0
Ox 0
VIFx
15.2
90.0
st1
EXIST NG HOUSE-D
c 19214
301
787
0
0
Ox 0
VIFx
0
0
LAU D.
h 418
8
7
0.456
4.0
Ox0
VIFx
19.5
90.0
st1
NW 1BATH
c 719
29
29
0.458
5.0
Ox 0
VIFx
19.1
90.0
st1
NE ,PEDROOM
c 2632
61
108
0.478
ZO
Ox0
VIFx
14.6
90.0
st1
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
N 11me
Type
(cfm)
(cfm)
FR
(fpm)
(in)
(in)
Material
Trunk
st1
PeakAVF
98
146
0.456
268
10.0
0 x 0
VinIFIX
Grille
Htg
Clg
TEL
Design
Veloc
Diam
H x W
Stud/Joist
Duct
Na ,I a Size (in)
(cfm)
(cfim)
(ft)
FR
(fpm)
(in)
(in)
Opening (in)
Matl
Trunk
rb1�i Ox0
400
933
0
0
0
0
Ox 0
VIFx
Boldlrtalic values have been manually ovemdden
wrightsoft® 2019-Feb-08 09:11:41
.M.t�•�,k�..�,e. «w, Right-SuteOUriversal201818.0.16RSU08101 Page
1Doameris\WrigtboftHVACVSERNIAADDITION.rLp Calc=MJ8 Front Door faoes:NE