FL O �'IIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Flor �� a Department of Business and Professional Regulation - Residential Performance Method
Project N ile:Lot027 F1833 B LHG Den - W
Builder Name: Ryan Homes
Street: 5274 OAKLAND LAKE CIR
Permit Office: St. Lucie
Shad's NNEO
City, Stat ' Zip: FT. PIERCE , FL ,
Permit Number:
By
Owner:
Design L��Ication: FL, Fort Pierce
Jurisdiction: 661000
County:: St. Lucie (Florida Climate
Zone 2 ) �� ���,� ������
1. New corLtruction or existing New (From Plans)
9. Wall Types (1707.3 sqft.)
Insulation Area
2. Single f 'mily or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1365.00 ft2
lof
b. Frame - Wood, Adjacent
R=11.0 342.33 ft2
3. Numbe units, if multiple family 1
c. N/A
R= ft2
4. Numbe of Bedrooms 3
d. N/A
R= ft2
(worst
10. Ceiling Types (1833.0 sqft.)
Insulation Area
5. Is this case? No
a. Under Attic (Vented)
R=30.0 1833.00 ft2
6. Conditi !ned floor area above grade (ft2) 1833
b. N/A
R= ft2
Ilned
RDuc
Conditi floor area below grade (ft2) 0
11. s
R ft2
7. Windo s(170.8 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 366.6
a. U-F ctor. Dbl, U=0.54 117.51 ft2
SH C: SHGC=0.31
b. U-F � ctor: Dbl, U=0.63 53.33 ft2
12. Cooling systems
kBtu/hr Efficiency
SH C: SHGC=0.32
a. Central Unit
28.0 SEER:14.00
c. U-F ctor: N/A ft2
SH C:
13. Heating systems
kBtu/hr Efficiency
d. U- ctor: N/A ft2
a. Electric Heat Pump
27.8 HSPF:8.20
SH, C:
Area Weighted Average Overhang Depth: 1.000 ft.
Area eighted Average SHGC: 0.313
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor types (1833.0 sqft.) Insulation Area
EF:0.900
a. SI -On-Grade Edge Insulation R=0.0 1833.00 ft2
b. Conservation features
b.N/AI R= ft2
None
c. N/ R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 57.70
Glass/ loor Area: 0.093
PASS
,
Total Baseline Loads: 58.36
i
I hereb certify that the plans and specifications covered by
Review of the plans and
a Sri
this cal ulation are in com lance with the Florida Energy
specifications covered by this
,y��� _ �0�,
Code:
calculation indicates compliance
Code.
ski` �,,, ' =_' � -
h :;: O
with the Florida Energy
;�-;:�•"���„
rrp,��.;
PREP RED BY:
Before construction is completed
DATE
this building will be inspected for
compliance with Section 553.908
l
I here y certify that this building, as designed, is in compliance
Florida Statutes.
, 5�
COD
with th ,I Florida Energy Code. ^
OWN R/AGENT: �•..�, .�` J
BUILDING OFFICIAL:
WE
DAT 'i �i-� "1 - a
DATE:
i
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
cert fied factory -sealed in accordance with R403.3.2.1.
- Co pliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envel pe leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Co pliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
test in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 On for whole house.
C ®C'v
P
8/1 12018 10:01 AM EnergyGauge® USA FlaRes2017 Section R405.4.1 Co plialLE Age 1 of 4
i
FnRM Ran -9n17
!I
PROJECT
Title:
Building T pe:
Owner N e:
# of Units I
Builder N me:
Permit O ice:
Jurisdicti �:
Family T e:
New/Exis `ng:
Commen l
Lot 027 F1833 B LHG Den - Bedrooms: 3
User Conditioned Area: 1833
Total Stories: 1
1 Worst Case: No
Ryan Homes Rotate Angle: 180
St. Lucie Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Street Address
Lot # 027
Block/Subdivision: Oakland Lake Es
PlatBook:
Street: 5274 OAKLAND LAKE
County: St. Lucie
City, State, Zip: FT. PIERCE,
FL,
it
CLIMATE
/
v Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299 62 Low
BLOCKS
Numb r
Name
Area Volume
1
Blockl
1833 15947.1
SPACES
Num 'er
Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled Heated
1
Main
1833 15947.1 Yes 4
3
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 157.5 ft 0
1833 ft2
---- 0.29 0 0.71
ROOF
#
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt Emitt Deck Pitch
Tested Tested Insul. (deg)
i
1
Gable or Shed Composition shingles 1985 ft2 382 ft2 Dark
0.5
N 0.5 No 0 22.6
jl
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300 1833 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1833 ft2 0.1 Wood
8/15/,2018 10:01 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4
I
FORM R4n' -Pnl7
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
Ft In Et In Area R-V:;Ilje Fraction Ahqnr (33 0
1
2
3
4
5
>S Exterior Concrete Block - Int Insul Main
>W Exterior Concrete Block - Int Insul Main
1 >N Exterior Concrete Block - Int Insul Main
=>E Exterior Concrete Block - Int Insul Main
'>SE Garage Frame - Wood Main
4.1 48 0 8
4.1 30 6 8
4.1 28 6 8
4.1 50 6 8
11 39 6 8
8 416.0 ft2 0
8 264.3 ft2 0
8 247.0 ft2 0
8 437.7 ft2 0
8 342.3 ft2 0
0 0.5
0 0.5
0 0.5
0 0.5
0.25 0.5
0
0
0
0
DOORS
Ornt Door Type Space
# p
yp
Storms
U-Value Width
Ft In
Height
Ft In
Area
1 E=>W Insulated Main
2 -=>SE Wood Main
None
None
.4 3
.46 2 8
6 8
6 8
20 ft2
17.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 180 degrees).
/
V
Wall
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Overhang
Area Depth Separation
Int Shade
Screening
1, N=>S 1 Metal Law-E Double Yes
e=>W 2 Metal Low-E Double Yes
S=>N 3 Metal Low-E Double Yes
w=>E 4 Metal Low-E Double Yes
W=>E 4 Metal Low-E Double Yes
0.54 0.31 N
0.54 0.31 N
0.54 0.31 N
0.54 0.31 N
0.63 0.32 N
3.1 ft2 1 ft 0 in 2 ft 0 in
49.0 ft2 1 ft 0 in 2 ft 0 in
16.3 ft2 1 ft 0 in 2 ft 0 in
49.0 ft2 1 ft 0 in 2 ft 0 in
53.3 ft2 1 ft 0 in 2 ft 0 in
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
None
None
None
None
None
None
II
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1 411 ft2 411 ft2
64 ft
8.7 ft
1
INFILTRATION
#
S
ope Method SLA
CFM 50 ELA EgLA ACH ACH 50
1 Who ehouse
Proposed ACH(50) .000387
1860.5 102.14 192.09 .2825
7
HEATING SYSTEM
jl
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
HSPF:8.2
27.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type Subtype
Efficiency
Capacity Air Flow
SHR Black
Ducts
1 Central Unit/ Split
SEER: 14
28 kBtu/hr 840 cfm
0.75 1
sys#1
8/15/2018 10:01 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4
i
FORM R40 -2017
HOT WATER SYSTEM
System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric None
Garage
0.9 50 gal 60 gal
120 deg
None
SOLAR HOT WATER SYSTEM
Collector
Storage
J�'FSEC
,�ert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
/
Supply ----
---- Return----
Air
CFM 25
CFM25
HVAC #
v
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN RLF
Heat Cool
1 Attic 6 366.6 ft
Main
91.65 ft Proposed Qn
Main
--- cfm
73.3 cfm 0.04
0.50
1 1
TEMPERATURES
Program
° ble Thermostat: Y
Ceiling Fans:
Coolingj
Heatin
i
j Jan [ jFeb jj jj Mar
f, j Jan [Xl Feb [X] Mar
E
Apr
Apr
Ma Jun Jul
f May 4 Jun 4 Jul
Au
Au4
Xj Se
]Sep
E
Oct
Oct
Nov
Nov
Dec
Dec
Venting[x�]
Jan [ ] Feb [[XX]] Mar
[X]
Apr
[ May [ Jun [ Jul
Aug
[ ] Se
[X]
Oct
Nov
Dec
Thermost
Schedule: HERS 2006 Reference
Hours
dule
Scheype
. 1
2
3
4 5 6
7
8
9
10
11
12
Cooling (
D) AM 78
78
78
78 78 78
78
78
80
80
80
80
PM 80
80
78
78 78 78
78
78
78
78
78
78
Cooling (
EH) AM 78
78
78
78 78 78
78
78
78
78
78
78
PM 78
78
78
78 78 78
78
78
78
78
78
78
Heating (
D) AM 66
66
66
66 66 68
68
68
68
68
68
68
PM 68
68
68
68 68 68
68
68
68
68
66
66
Heating (
EH) AM 66
66
66
66 66 68
68
68
68
68
68
68
PM 68
68
68
68 68 68
68
68
68
68
66
66
8/15/2018 10:01 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4
Florida Building Code, Energy Conservation, 6th Edition (2017)
atory Reauirements for Residential Performance, Prescriptive and ERI Methods
ADDRES : 5274 OAKLAND LAKE CIR Permit Number: I
FT. PIERCE, FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
SECTION R401 GENERAL
R401!3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL)
displ�y card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Sec,on 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
insta �ed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and "pecifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD.
Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
;tions R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing
methods between dissimilar materials shall allow for differential expansion and contraction.
R40 .4.1.1 Instal lation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with 4he manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required
by t °e code official, an approved third parry shall inspect all components and verify compliance.
R4 '2.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
cl ges
per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
acc rdance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
offi 'jal. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
n: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended
weatherstripping or other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond
intended infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the
ce. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907.
.3 Fenestration air Ieakage.Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or
WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. -
Exception: Site -built windows, skylights and doors.
5/2018 10:02 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
111402.4 $4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open c mbustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclos d in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Tab[' R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be
fully g keted and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passe jthrough conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
R402.4. ! Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more th 0 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminair s shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 ontrols.
R40 I.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R40 .1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
at, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R40 .3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3.3.
R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the
manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test.
Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the
entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
R403. ?5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
R403. Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 1050F (41 `C)
or belo N 55°F (13°C)shall be insulated to a minimum of R-3.
R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in
accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return
pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
5/2018 10:02 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complian Page 2 of 5
MAND'!,�►TORY REQUIREMENTS - (Continued)
R403.5.5 eat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat 1; aps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 1/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible
to thgl storage tank.
R403II'5.6 Water heater efficiencies (Mandatory).
R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
setting range shall be from 100°F to 140°F (38°C to 60°C).
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of
combustion types of service water -heating systems to be turned off.
R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water -heating systems. . Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
orida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
cluding: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
cse when the ventilation system is not operating.
R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be
powered by an electronically commutated motor.
R403.6.2 Ventilation air. When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
7 Heating and cooling equipment (Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that
affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFM/WATT)
AIRFLOW RATE MAXIMU
(CFM)
Range hoods
Any
2.8 cfm/watt
Any
In -line fan
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
<90
Bathroom, utility room
90
2.8 cfm/watt
Any
_ I
or SI: 1 cfm = 28.3 L/min.
8/15/2018 10:02 AM
I'
a. When tested in accordance with HVI Standard 916
EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 3 of 5
MAN 'ATORY REQUIREMENTS - (Continued)
R403.7.1 'I1I Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than he calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Secti; n 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
equi �ent shall not be less than the calculated latent load.
The publ shed value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's
expande I performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temperat' re for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance ce data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature.
Design v lues for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of
equipment may be sized in accordance with good design practice.
R40 L7.1.2 Heating equipment capacity.
403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
3.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
and C404 of the IECC—Commercial Provisions in lieu of Section R403.
Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building,
II include automatic controls capable of shutting off the system when the pavement temperature is above 50IF (101C), and no
:ipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.81C).
i 10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
(shall be in accordance with Sections R403.10.1 through R403.10.5.
R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
5/2018 10:02 AM EnergyGauge® USA - FlaRes2017 - FBC 6th Edition (2017) Complia Page 4 of 5
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
,with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 ortable spas (Mandator90he energy consumption of electric -powered portable spas shall be controlled by the
requirem' nts of APSP-14.
SECTION R404
LECTI ICAL POWER AND LIGHTING SYSTEMS
R404.1 L fighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be
high-effic cy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps.
Exception: Low -voltage lighting.
R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
8/1 /2018 10:02 AM Ener Gau eO USA - FlaRes2017 - FBC 6th Edition 2017 Com lia Page 5 of 5
9Y 9 i ) P 9
FORM
1. New co
2. Single
3. Numbe
4. Numbe
5. Is this
6. Conditi '
7. Windo
a. U-F4
b. U-
S!,
c. U-
S1
d. U-
Area wI
Area W
8. Floor
a. Slab
b. N/A
c. N/A
I certify
Constrt
in this f
based c
Builder
Address
17
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
struction or existing
imily or multiple family
of units, if multiple family
of Bedrooms
worst case?
ned floor area (ft2)
Description
;tor: Dbl, U=0.54
SHGC=0.31
;tor: Dbl, U=0.63
SHGC=0.32
:tor: N/A
N/A
Average Overhang Depth:
Average SHGC:
Edge Insulation
5274 OAKLAND LAKE CIR, FT. PIERCE, FL,
New (From Plans)
9. Wall Types
Single-family
a. Concrete Block- Int Insul, Exterior
b. Frame - Wood, Adjacent
1
c. N/A
3
d. N/A
10. Ceiling Types
No
a. Under Attic (Vented)
1833
b. N/A
Area
c. N/A
117.51 ft2
11. Ducts
a. Sup: Attic, Ret: Main, AH: Main
53.33 ft2
12. Cooling systems
ft2
a. Central Unit
ft2
1.000 ft.
0.313
Insulation Area
R=0.0 1833.00 ft2
R= ft2
R= ft2
13. Heating systems
a. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
it this home has complied with the Florida Energy Efficiency Code for Building
:)n through the above energy saving features which will be installed (or exceeded)
le before final inspection. Otherwise, a new EPL Display Card will be completed
nstalled Code compliant features.
Inature: j�,� , �� Date:
f New Home: 5 Z 'ILA nJ-/'&V'A \- C ,o C V.r, City/FL Zip: }-�.�►PrcA , FL.
3%10f&1
Insulation
Area
R=4.1
1365.00 ft2
R=11.0
342.33 ft2
R=
ft2
R=
ft2
Insulation
Area
R=30.0
1833.00 ft2
R=
ft2
R=
ft2
R ft2
6 366.6
kBtu/hr Efficiency
28.0 SEER:14.00
kBtu/hr Efficiency
27.8 HSPF:8.20
Cap: 50 gallons
EF: 0.9
Pstat
y00�IiE ST.grAoo
6
if
�oD WE��
*No 'e: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mo gage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
tec �upport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
cert fied Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Co ,,mission's support staff.
required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
8 10:01 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project
Name: Lot 027 F1833 B LHG Den - W Builder Name: Ryan Homes
Stre
#: 5274 OAKLAND LAKE CIR Permit Office: St. Lucie
City,
Mate, Zip: FT. PIERCE, FL, Permit Number:
Own
I
r: Jurisdiction: 661000
Desii
in Location: FL, Fort Pierce
COM
il
ONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
require
ents
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
Ceiling/
ttic
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windom
s, skylights
The space between window/doorjambs and framing, and
and do
rsd.
skylights and framing shall be seale
Rim joi
is
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(includi
g
insulation.
maintain permanent contact with the underside of
above
'arage
subfloor decking, or floor framing cavity insulation
and car
tilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space
walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls
Shafts,
penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
(cavities
cavities shall be filled by insulation that on
Narrow
installation readily conforms to the available cavity
spaces.
Garage'separation
Air sealing shall be provided between the garage and conditioned spac
as.
Reces
d lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbi
�g and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Showe%tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on ext
Sior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone
box or
The air barrier shall be installed behind electrical or communication
extedo ';(walls
boxes or air -sealed boxes shall be installed.
HVAC
egister boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Conce 'led
When required to be sealed, concealed fire sprinklers shall only be
spdnkl 'rs
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprffinki rover Intes and walls or ceil'
a. In ad • ition, inspection of log walls shall be in accordance with the provisions of ICC-400.
8/15/20 8 10:02 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
i
1•
ro ect Summary Job: F1833 B LHG Den
+�+ Pry
rightsoft® Date: 05/14/2018
Entire House By: XF/RINCIF
One Stop Cooling and Heating
7225 Saud II, ve Court, Wirier Park, FL 32792 Pfnrw (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopCoolingmm Licerse: CAC032444
For: Ryan Homes
Notes:
Weather:
Winter Design Conditions
re db b 642 8 cFan TD 26 °F
Fort Pierce, FL, US
Heating Summary
Structure
17322
Btuh
ucts
1765
Btuh
Central vent (0 cfm)
0
Btuh
!1 (none)
umidification
0
Btuh
ping
0
Btuh
uipment load
19086
Btuh
Infiltration
Method
Simplified
nstruction quality
Average
ireDlaces
0
i Heatingg Coolingg
ea (fte) 1838 1838
�folume (ft3) 15991 15991
1?�ir char ei3ftur 0.38 0.20
uiv AVF (cfm) 101 53
Heating Equipment Summary
ake Goodman Mfgg.
rade GOODMAN; JANITROL;AMANADISTI...
odel GSZ140301 K
RI ref 7995113
y eating input
eating output
emperature rise
al air flow
I F,aD
ow factor
c pressure
thermostat
aciiy balance point = 33 `F
Calculations a
8.2 HSPF
27800 Btuh @ 47 °F
0 cfrn
0 cfm/Btuh
0.50 in H2O
r
Summer Design Conditions
cF
IInnsdedbb
72
`F
Design TD
18
°F
Daily range
M
Relative humidity
50
%
Moisture difference
68
grAb
Sensible Cooling Equipment Load Sizing
Structure
17387
Btuh
Ducts
3492
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data
n
Rate/swin multiplier
0.95
Equipmenisensible load
19835
Btuh
Latent Cooling Equipment Load Sizing
Structure
3259
Btuh
Ducts
899
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
4158
Btuh
Equipment Total Load (Sen+Lat)
23993
Btuh
Req. total capacity at 0.75 SHR
2.2
ton
Cooling Equipment Summary
Make Goodman Mfgg.
MIA
Trade GOODMAN;
Trade DISTI...
Cond GSZ140301 K
Coil ARUF31614A
AHRI ref 7995113
Efficiency 12.0 EER,14 SEER
Sensible cooling
21000
Btuh
Latentcooling
7000
Btuh
Total cooling
28000
Btuh
Actual airflow
933
cfm
Airflowfactor
0.045
cfm/Btuh
Static pressure
0.50
in H2O
Load sensible heat ratio
0.83
ACCAto meet all requirements of Manual J 8th Ed.
-pp- wrG9ht--soft-
m Rigk-Suite®Uriversal201818.0.19 RSU23249
or\Des1dop\TEMP1ot 027 F1833 B LHG Den- W.nQ Calc = W8 Frort Door faces: W
2018-Aug-15 09:51:59
Page 1
-�- w 'ightsoRight-J® Worksheet
Entire House
One Stop Cooling and Heating
7225 Sand;.cove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopGooling.com License: CAC032444
Jab: F1833 B LHG Den
Date: 05/14/2018
By: XF/RI/MULF
1
2
3
4
5
R
RoFim
R
Room
m name
sed well
height
m dimensions
area
Entire House
157.5 ft
8.7 ft d
1838.0 fF
MBED
31.0 ft
8.7 ft heat/Oool
14.0 x 17.0 ft
238.0 tF
Ty;
Construction
number
IJ-vdlUe
(BtuW F)
Cr
HTM
(BtjW
Area (fp)
or perimeter (ft)
Load
(Btuh)
Area (f2)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Goss
N/Pi5
Heat
Cool
Gross
Nlps
Heat I
Cool
6
11
`
n '
-n-
a
a
a
- s7
-s_
w
w
w
- -
_n_
' 3.72
_ 14D.4
3.72
14.04
10.14
--372.
_14.04.
3.72
14.04
16.38
- 237
:--10.14,
0.83
_262
`.1436;.
2.62
34.14
_-_ 1150
M 2
__1436
2.62
34.14
42.09
',- -=1
-13
-_1150
1.70
- -
r 000
` _--418
- __3'---.:0
265
49
_ 20
_ 248
_ 16
439
49
- -- 54
"__1.8
1838
- - -
_ -1836
`-- -- 41_5
196
0
20
_ _212
_- 16
337
0
_ - 0
�
= , 18
1838
-- -
158
1541
- . 43
- 7085
44
-148
0'
0
0
- .- 0
_ _ _ 0
122
33
0
-_ _. 0
=- --1'48
0
T 550
__0,
987.
--.0
13A 4ors
4A5.2om-
13A 4ors
4A5-tam
11 DO
0143
_-0540
0.143
0540
0.390
_ 7 -.143
0540
0.143
0540
0.630
_- OA91
=0390
0.032
_G
730
688
204
- 861
229
1252
688
878
--- .
____181,
1529
-,.�--
_ 4832
514
1674
231
�_l..606
--___ 235
881
1674
2256
�-_-�
_-__206
0
0
0
_ ---- 0
_--_-__0
89
0
0.--__0
. 0
___0
238
0
0
0
. b
0
0
0
0
EZ5
13A-4ars -
4A5.2om
13A-4ocs
4A5-2om
4A5-2omd
12C-Os_w -.
.11DD - __
166-30ad
I
331
459
0'
-_0
198
-- -I
233
1116
0
0
- 0.
404
------
'
--
i .
-i
C
:F
II
9
3117
_ 0
._�0
238
---
_238
_
-- 1.180
- -
--- -
_ O_M
31
-951_
0.
_--
-
_
-
--
6
dOED
excursion
758
304
E$velp.
loss!gain
14428
13712
2489
2444
12
a
b
Infiltration
Room ventilation
2894
0
1054
0
570
0
208
0
13
1
malgains: Oowpants@ 230
Applianoes(other
4
920
1700
2
460
0
SUl�btotal
(lines 6to13)
17322
17387
3059
3112
14
15
Lasstransler
r I
i
external load
edistribution
btotal
Lctloads
100/0
20%
0
0
0
17322
1765
0
0
0
17387
3492
10%
2D%
_7
0
0
0
3059
312
0
0
0
3112
625
Ital
room load
required (dm)
19086
0
20879
933
3370
0
3737
167
Calculations
�.F- wrigF�tsoft^
Right-Stite®Uriversal 201818.0.19 RSU23249
or\Desldop\TEMP\Lot027F1833BLHGDen- W.np Calc=W8 Front Door faces: W
2018-Aug-15 09.51:59
Page 1
wrIghts0 Right-J® Worksheet yob: FB LHG Den
Entire House Date: 05e33 /14/
By: XF/RI/MC/MC/LF
One Stop Cooling and Heating
7225 Sand ve Cout, Wirter Parts, FL 32792 Plnre: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCooling.00m Uoerse: CAC032444
1
2
3
4
5
R
R
R
R
Im name
sed wall
m height
m dimensons
"m area
MBTH
14.5 ft
8.7 ft heaVcool
1.0 x 109.5 ft
109.5 itz
MWIC
0 ft
8.7 ft heaV000l
6.5 x 10.5 ft
683 fF
Ty
ConstrucliOn
number
U-value
(BtuWl--)
Or
HTM
(BtuW
Area (fV)
or perimeter (ft)
Load
(BWh)
Area (fil)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/PnS
Heat
Cool
I Gross
NA'iS
Heat
Cool
6
11
'
� -
III
II
y-
- -
13A-flocs -� ..
'_4A5.2Dm.,_-_- __ - -'
13A-4ocs
4A5-2om
11 DO
-
13A-4ors
_4A5.2om -_. _
13A-4ocs
4A5-2om
4A5-2omd
12C Osnr
11D0_^ _ _ __
16&30ad
-0:343
0540
0.143
0.540
0.390
0.143
_ - : 0590
0.143
0.540
0.630
0.091
_ _0390
0.032
_
4 n
-n-_
a
a
a
s
- s--
w
w
w
.n_
- --
3.72
-_-14A4
3.72
14.04
10.14
- 372
.- 14A4
3.72
14.04
16,38
237
._ - 10.1.4,
0.83
-_.. _
: , 2.62
1436
2.62
34.14
_ 11.50
" 2B2
1436
2.62
34.14
42.09
133
,�1150
1.70
----
0.00
. 126
3
: 124
0
458
43
-
, 322
. 44
0
0
0
0
0 -- -
0
----
� 0
0,
_
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
- -
`-" U
0
0
0
� -' 0
Vy
L-
�0
0
0
0
0
0
0
0
0
0
0
0
U
0
0
'�-U
0
_C
1
0
0
0
0
0
0
-0
0
0
0
0
0
0
-0-0,
0
0
0
0
0
0
-- -- 0
__0
116
0
_0
110
0'
0
-0
0
0
186
0
0
68
- -- 0
0
- --0
- �0
57
_
C
110
-0
91
68
110
15.
-
445
-0
_ -68.
0=
0
-
__-_0
_
__._�_ _vim.,--�___-.-
__-_�_
_:I
_-'
---_e
_
_
-_—__
-
---•__
-
6
c)
D excursion
-53
-10
Ervelope
loss/gain
1036
498
57
106
12
a)
b)
Infiltralion
Room verdlafton
266
0
97
0
0
0
0
0
13
Int
Mal gains: Ocuds @ 230
par
I Appliances/other
0
0
0
0
0
0
S
total(lines6to13)
13 33
595
57
106
14
15
Le
Le
R"
SL
D
s Mama] load
transfer
istributon
AOtal
,Roads
10%
20%
0
0
0
1303
1,13
0
0
0
595
120
10%
20%
0
0
0
57
6
0
0
0
106
21
To
Ai
al room load
Fequired (dm)
1435
1 01
715
32
1
63
01
128
6
Calculations
-F- w jopvts JzC-
""" " Rigll-Suite®Udversal201818.0.19 RSU23249
or\Desldop\TEMP\Lot027 F1833 B LHG Den- W.rup Calc= W8 Front Door faces: W
2018-Aug-15 09:51:59
Page 2
' I
w I',ightsoft Right-J® Worksheet
Entire House
One Stop Cooling and Heating
7225 Sandpove Court, W irter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OrLStopCooling.com License: CAG032444
Jab: F1833 B LHG Den
Date: 05/14/2018
By: XF/RI/MC/LF
1
2
3
4
5
Ro
R
R
R
51m name
" v"1
"m height
Im dimensions
� m area
DEN
30.0 ft
8.7 ft heat/cool
135 x 13.0 ft
175.5 iP
FOY
55 ft
8.7 ft heat/Oool
5.5 x 9.0 ft
49.5 f12
Ty
Construction
number
U-value
(B1uhRtZ�j
Or
HTM
(BtuhgF)
Area (ft)
or perimeter (ft)
Load
(Bhuh)
Area (fP)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
NIPS
Heat
Cool
Gross
NOS
Heat
Cool
6
11
`
�-
`f
13A 4ors
-4A�2om
13A 4acs
4A5 tom
11 DO
13A-4ots
_4A52om
13A-4ots
05-2om
4A5-2omd _
12CQwv
11D0 .
16B-30ad
0.143
0540
0.143
0540
0390
_ _ 0:143
OS40
0.143
0540
0.630
- 0.091
0390
0.032
n'
-n_
a
a
a
s
_s,
w
w
w
-------
3.72
14.04
3.72
14.04
10.14
:3.72
-1_4.0.4.
3.72
14.04
1638
252
= 1436
2.62
34.14
11.50
_ :F&
1436
2.62
34.14
42.09
__ 1,
- 1150
1_70
--- 0.00
-
113
: 0
117
16
0
30
-L . ' 0
--------
113
421
_0_0
376
229
0
: _ -- f 3
_ _0.__
0
0
- 0
- p
0
- -
- - 296
_--__0
265
558
0
, - gp
__ -0
0
0
-- 0
0
_ _.9
-298
_----- --U
0
__--.0._
48
0
20
_-- _ _. _ 0
----,0.-
0
0
0
0
^- --0
_ 50
--`'0
- -
0
---0
28
0
20
_ _. _ .r- -0
_0
0
0
- - 0
,___ _ _-0
- 450
--. --__6
-- -
0
�-_-__0
103
0
204
-- ^-
0
--_ 0,
73
0
231
-_- 0
' .-.__0
0
0
-- 0
--..-0
,- 84
___
-.-.__...0
101
0
0
' 30
-__0
0
0
_ -- 0
p
__0'
176
30
_ -_ _ 0
-:___0
0
0
- --- 0
0
0
0
_ ----0
0'-
_ 176
--- 1.7.6
_ _ _
. ne
Off
10.14.
0.83
C
146
=920
_
41
__ 169
-F
_
;,-
22A cptn _ _
_
_ 1.160
_
_-30.68
6
c)
D excursion
1
-35
Er
lope loss/gain
2205
14961
517
353
12
a)
b)
Infiltration
Room ventilation
551
0
201
0
101
0
37
0
13
IAmalgains:
Occupants@ 230
Appliances/other
0
0
0
0
0
0
S
¢ otal (lines 6 to 13)
2757
1697
1618
390
14
15
Less
R
S
D
e)d mal load
transfer
distribution
total
i4loads
101%
20%
0
0
237
2993
305
0
0
149
1846
371
100/0
200/6
0
0
-618
0
0
0
0
-390
0
0
T
Ai
room load
(required (dm)
3298
1 0
2217
991
0
0
0
0
— wrightsoft�
Rigtt-Sute@Uriversal 201818.O.l9 RSU23249
or\Desldop\TEMP\Lot027 F1833 B LHG Den- W.rup Calc = W8 Front Door faces: W
2018-Aug-15 09:51:59
Page 3
I
- WE igntsofr Right-J® Worksheet
Entire House
One Stop Cooling and Heating
7225 Sand ve Court, W irter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOrLStopGooling.com License: CAC032444
Job: P1833 B LHG Den
Date: 05/14/2018
By. XF/RI/MC/LF
1
2
3
4
5
R
R
R
R.
Im name
° well
"m height
°m dimensions
'm area
DIN
15.Oft
8.7 ft heat/aool
11.5 x 125 ft
143.8 F
KIT
Oft
8.7 ft heaU000l
1.0 x 297.8 ft
297.8 fP
Ty
Construction
number
U-value
(Btuw-q
Or
HTM
(BWM12)
Area (fF)
or perimeter (ft)
Load
(BWh)
Area (fF)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
I N/PiS
Heat
Cool
Gross
NAS
Heat
Cool
6
11
-
.13A flocs -
4A5-2om _ _ _
13A-4ocs
4A5 tam
11 DO
13A-0as
4A2om -- _ _- - -
13A-4ocs
4A5-2om
4A5-2omd
12C-Osw . =
16B-30ad
—
0.143
___0-940
0.143
0.540
0.390
- 0143
_ - =0.540
0.143
0540
0.630
OD91
- 0.032
n
-n_-
a
a
a
s
; _s-_
w
w
w
_
3.72
.-_ 14.04
3.72
14.04
10.14
3.72
_ _ _14.04
3.72
14.04
16.38
�
- 10.14
0.83
_ -_..
- 30 G8
262
-- - 30
-0
0
0
0
0
0
-- — 0
--0
0
0
0
`----81
____._-0.
505
30
0
113
0
80
0
0
0
--0
0
6
0.._-
_ -1436
2.62
34.14
1150
2622
:-_ 1436
2.62
34.14
42.09
.- 133
_ -1150
1.70
- --
0.00
100
33
-_ - 0
_a 0
0
0
0
..-.. 109
67
0
0
250
459
0
176
1116
0
0
0
0
0
0
0
0
0
0
T 0
; _--0
0
0
0
- - 109
0
0
0
0
0
0
0
0
0
_ 0
0.
�!i
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
�FLT,
, _297
0
144
0
61
0
61
144
C
F
---0
144
---
'. 144
144
-
120
244
298
—0
298
—0
248
- 15
--
460
0
�298
0
-
0
_ 0_
--- -
-- — -- -
--- - —
—_— - —
-
61
c)
I D excursion
127
-147
En
lope loss/gain
1660
1887
392
439
12
a)
b)
Infiltration
Room ventilation
276
0
100
0
0
0
0
0
13
1malgains: Ocupants@ 230
Applianoesrother
0
0
0
0
0
1200
S
total (lines 6 to 13)
1935
1988
392
1639
14
15
Le
Le
R
D
a external load
transfer
" istribution
tal
d loads
10%
20 %
0
0
237
2172
221
0
0
149
2137
429
10%
20%
0
0
145
536
55
0
0
91
1730
347
Topil
Ai
room load
�equired (dm)
2393
0
2565
115
591
0
2077
93
wrightsolFtm
"""'"!%Lh "• Right-Stite®Universal 201818.0.19RSU23249
*Wp\TEMP\Lot 027 F1833 B LHG Den- W.nQ Calc = W8 Front Door faces: W
2018-Aug-15 09:51:59
Page 4
' III
+ wr�ghtsoft Right-J® Worksheet
Entire House
One Stop Cooling and Heating
7225 Sand ve Cout, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCooling.com License: CAC032444
Job: F1833 B LHG Den
Date: 05/14/2018
By. XF/RI/MC/LF
1
2
3
4
5
Rom
ENbDsed
R
R
R
name
uwll
"m height
°m cimensions
'm area
GRT
16.5ft
8.7 ft heaU000l
16.5 x 155 ft
255.8 ftz
BTH1
6.0ft
8.7 ft heat/000l
1.0 x 795 If
795 f12
Ty
Construction
number
U-value
(Btuh/ftz n
Or
HTM
(Btuhl(
Area (fF)
or perimeter (ft)
Load
(Btuh)
Area (ftz)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/PiS
Heat
Cool
Gross
N/P/S
Heat
Cool
11
I --'
�^
TG
---
0
0
0
---0
235
0
2256
- - --
0
----0--
0
0
_ 0
__�___0
52
0
0
- -
- 0
_.-0
80
BO
- - - --
0
0
0
0
-- ---0'
52
0
0
- -' 0
0:
-- - -- -- 0
0
0
0
- - --0
194
0
0
- --
0
_- -0
_ 66
---0
0
-0
0
0
0
------0
137
0
0
- - - --
0
._. ---0,
135
�3A4ois---�
13A-4ocs
4A5-2om
11 DO
0.143
0540
0.143
0.540
0.390
n-•
-n_
a
a
a
` -3.72
14D.4.
3.72
14.04
10.14
-
- 26L0-
1436
_ 0
2.62
34.14
11.50
0
0
0
0
0
0
0
0
0
13A 4ors
4A5.2om--:
13A-4ocs
4A5.2om
4A5 2omd
--
12C-0sw
1613-30ad
0.143
- 0540
0.143
0540
0.630
---• 0.091
-.._-0390
0.032
s
_s_
w
w
w
'-�
-
_n-
3.72
._�.14.04
3.72
14.04
1638
1436
0
- 0
- - --
-. 0
VLF
I
I
-
2.62
34.14
42.09
144
0
54
90
0
0
334
0
878
--
IL
237
—1.014;
0.83
_ -____.
i33
1150
1.70
- 0
0
--P
' - 0
__0
256
�—
- 0
0
.--
0
—_.___0
434
_�- �0'�^_
C
_F _',
256
213
506
-___-
8
_0
^ - -J -8
22A-cpm -__
m_1,180
,
�30.68.
�0.00
- 256iZ
7--
7-
-
�
I,I
—
--
-
-
--
--
6
c
D excursion
624
- - -
----
—
— 26
e lope loss(gain
1 1931
35491
444
246
12
a)
b)
Infiltration
Room ventilation
303
0
110
0
110
0
40
0
13
Ind
me]gains: Oaztpants@ 230
Applianoesbther
0
0
0
0
0
0
Su'
tat (lines 6to 13)
2235
3660
555
286
14
15
R
Su"
D
external load
transfer
"istribution
tal
loads
10%
20%
0
0
5
2239
228
0
0
9
3669
737
10°/
20/.
0
0
8
563
1 57
0
0
15
301
60
TO
Ai
room load
'eguired(cfm)
2467
01
4406
197
1
620
0
362
16
MA to meet all requirements of Manua
rIFI,-
wviotmts Im- 2018-Aug-1509:51:59
. COCARigFt-Sute®Universal2018 18.0.19 RSU23249 Page 5
or'Desldop\TEMPLot 027 F1833 B LHG Den- W.np Calc = MJ8 Front Door faces: W
I
F�- Job: F1833 B LHG Den
w ightsoft" Right-M Worksheet
2018
Entire House Date: 05/14/
By: XF/RUMC/MC/LF
One Stop Cooling and Heating
7225 Sard I 3cove Court. Winter Park FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopCooling.com License: CAC032444
1
2
3
4
5
Room
R
R
R
name
*sed wall
m height
m dimensions
" m area
BED2
26.0 ft
8.7 ft heaUcool
1.0 x 160.5 It
160.5 fP
AC
0 ft
8.7 ft heaftol
5.5 x 35 ft
193 fR
Ty'
Construction
number
U-value
(BtUW g
Or
HTM
(Btuh/fn
Area (f�
or perimeter (ft)
Load
(Btuh)
Area (M)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/Pi5
Heat
Cool
6
11
13A-flocs-'------
4A52om__ _
13A-4ocs
4A5 2om
11DO
4A2om
13A-4ocs _
4A5-2om
4A5-2omd
12C Osyv >- - -
11D0 .-0390
168-30ad
_22A
• � -0.143
---0540
0.143
0.540
0390
�_0540
0.143
0540
0.630
- 6--
0.032
• n
_.n_
a
a
a
-s--'
w
w
w
: -
_ n.
3.72
.-.14.04
3.72
14.04
10.14
---_14.04.
3.72
14.04
16.38
-237
10.14.
0.83
-
2.62
- -, 1436
2.62
34.14
11.50
_ 2.62
_. -1.436
2.62
34.14
42.09
r 133
- 1150
1.70
-' 0
'____-0
0
0
0
_ - . IN
---;0.��=____0
122
16
0
-- - 0
--_01'
_ 161
0
— _ _0
0
0
---- 0
105
0
0
0
0
_0
0
. 0'
0
0
0
_.._0
0
0
0
0
0.
0
_0
0
0
0
8
0
0
0
_..� -0
0
0
0
0
0
0
0
0
0
l
_
1Q---�--�-
0
- -273
. 0-0-0
� 0
0
0
0
---- 0
- 0
-- 0
0„
0
0
0.
392
229
0
-., 0
0'
276
558
0
- - 0
0
0
0
0
0
0
0
0
0
0
j�
- 0—
0
0
_0
16
--. 0
0
C
F
I
y
161
134
272
19
19
33
25
----798
---0
�-19
0
� 0
0
u--
- --
-- --
- —
- -L-
-
—
--
-
6
c)
D exarsion
121
-3
inlelope
loss(gain
1941
1500
16
30
12
a);
b)
Infiltration
Room ventilation
478
0
174
0
0
0
0
0
13
I
�emalgains: Oavpants@ 230
i
Applianoesbther
1
230
0
0
0
0
bu(lines6to13)
2419
1904
16
30
14
1151
R
D
external load
transfer
" istribution
MU
ct loads
1 10%
20%1
0
0
5
2423
247
0
0
9
1913
384
100/(
2D-/.l
0
0
-16
0
0
0
0
-30
0
0
T
room load
required (dm)
2670
0
2297
103
0
0
0
0
(ACCAto meet all requirements of
fI.F wrigF�tsoiFt'°
RigFt-Sute®Uriversal201818.0.19RSU23249
or\Desldop\TEMP\Lot027 F1833 B LHG Den- W.rrp CaIc=W8 Front Door faces: W
2018-Aug-15 09:51:59
Page 6
w,'ightsoft- Right-J® Worksheet
Entire House
One Stop Cooling and Heating
7225 Sand nve Court, Winter Park, FL 32792 Phore: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCooling.com License: CAC032444
Job: F1833 B LHG Den
Dale: 05/14/2018
By- XF/RI/MC/LF
1
2
3
4
5
R
R
R
Ro
mname
wall
m height
m dimensions
m area
BED3
13.0ft
8.7 ft heattmol
1.0 x 156.3 ft
156.3 f6
LAUN
Oft
8.7 ft heatlmol
1.0 x 51.3 ft
51.3 ft'
Ty
Construction
number
U-value
(Btuh/ q
Or
HTM
(BtuhV)
Area (fF)
or perimeter (ft)
Load
(Btuh)
Area (fE)
or perimeter (ft)
Load
(Btuh)
Heat
I Cool
Gross
NIPS
Heat
Cool
Gross
NIPS
Heat
Cool
6
11
_
..
ID
IG
i
13A 4dcs -- --
4A5�rn -_ -
13A-4ocs
4A5-2om
11 DO
- -_ -- -
13A-4o s
4A5-2om
4A5-2omd
_ -_ - -
12C-0sw .
16B-30ad
0.143
_.__.�0.590
0.143
0.540
0.390
n
-n-
a
a
a
372
—145�
3.72
14.04
10.14
0
T 0
0
0
0
0
0
0
__.. _ ,0
10
0
0
0
� -51
____206
87
2 62
'__ _1_436
2.62
34.14
11.50
0
� 0
0
0
0
r0
0
- _~ U
0
—0
0
0
0
0
�—�o
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
-c
w--
_ e -0540
0.143
0.540
-. _-. 0.630
0.091
-___e__0390
0.032
.R
-s-
w
w
w
-
n_
-
3.72
— 4D-4
3.72
14.04
1638
L4 6
2.62
34.14
42.09
13
� 6
_ -6
0
0
0
-229
0
0
0
235
0
0
0
—.- U
-� _ 0
0
0
0
U
0
0
0
- - . -92:
____--181.
43
0
0
0
---:-0
0
0
0
- .. 39
18
51
C
237
: 1014
0.83'
_- _
' 133
--L11.50
1.70
- -
_ 117
0
—
117
0'
----
" 278
0
-- ---
15- 6
--0'—_
--- 5- 7
18
51
156
156
130
265
r F
ZZA art _ _ _-
--1180
._l
_ 30.68
r— --
-� U.00
�` 156
_ 13
-
399
0
81
--
--
----.
6
c)
D exwrslon
-72
-70
Emplopeloss(gain
1396
837
315
274
12
a)
b)
Infiltration
Room ventilation
239
0
87
01
0
0
0
0
13
Inte
al gains: Oocupants @ 230
Appliances/other
1
230
0
0
0
500
Sul
6tEd (lines 6to 13)
1635
1154
315
774
14
1151
Les
Re
Su
Du
external load
transfer
fisbibuflon
tal
4, loads 110%
20%
0
0
13
1648
168
0
0
24
1179
237
10%
2D-/.l
0
0
13
328
33
0
0
24
799
160
TOI
Air
room load
auired (cfm)
1816
0
1415
63
362
0
959
43
all reauirements of
wrigr�tsoft- 2018-Aug-15 09:51:59
A�k""" Rigld-SUteO Uriversal 201818.0.19 RSU23249 Page 7
r-rI0-sldop\TEMP\Lot027 F1833 B LHG Den- W.rLp Calc= WB Front Door faces: W
w',ignts0 Right-J® Worksheet
Entire House
One Stop Cooling and Heating
7225 Sard ve Court, W irter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCoolirg.com Licerse: CAC032444
Job: F1833 B LHG Den
Date: 05/14/2018
By- XF/RI/MC/LF
1
2F�_osed
3
4
5
Room
Room
Room
Rdom
name
wall
height
dimensions
area
H1
0 ft
8.7 ft heat(mol
9.5 x 35 ft
332 ftz
Ty
I
ConshvclJon
number
U-value
(BtuhAtzq
Or
HTM
(BtuW
Area (fF)
or perimeter (ft)
Load
(BMh)
Area
or perimeter
Load
Heat
Cool
Gross
NIPS
Heat
Cool
Gross
N/P/S
Heat
Cool
6
11
--'
—'13A-0acs
-4P&2omr----_—
13A-4ocs
4A5-2om
11 D0
13A�ocs
4A5-2om -
13A-4ocs
4A5-tom
4A5-2omd
12C:6i
11D0—.—.- __
16B-30ad
_ 22A-Wn
'— 0.143
=05 W
0.143
0540
0390
—n_
—n�
a
a
a
s
_s._
w
w
w
_n-
--
---- 3.72
-�1.4D4
3.72
14.04
10.14
_— 372
_ .14D.4
3.72
14.04
16.38
237
._--_10.1.4
— 0.83
_
_. .-212
'_ _•1436'
2.62
34.14
11.50
- - a2
:-- 1436
2.62
34.14
42.09
133
_ 1150
1.70
-.-. --0
- _ 0
0
0
0
_0
0
0
0
- 0
:.----0
33
-_-33
r_ U
,-�-0
- U,..r_--
—.----® 0-
0
0
. _ _ 0
0
0
0
0
—___-0
28
0
0
0
_ U
-__0
0
0
0
0
---0
56
--
___---
---
-
-- -
-
0
0
0
- . —0
0
0
0
0
.---0
33
—'
II
0.143
e_:-0540
0.143
0540
0.630
0.091
0390
0.032
1.180
-
_
�
_
LG
IL
1'-
_F
_
-
_—�-
_ 0
=-0
� ^ U--
44PED
6
c
exarsion — ---- --
—
— 511
Erhelope
loss/gain
28
52
12
al
b
Infiltration
Room venfilafion
0
0
0
0
13
Ir iemalgains:
Ooaipants@ 230
Appliances/other
0
0
0
btotal (lines 6 to 13)
28
52
14
15
IF
Eubtod
1
ssextemalload
transfer
-distribution
ict loads
101/6
20%
0
0
-28
0
0
0
0
-52
0
0
'r
tal room load
required (cfm)
0
0
0
0
of Manual J 8th Ed.
-�- wrightsoft°
Right-Sute®Universal 201818.0.19 RSU23249
or\Desldop\TEMP\Lot 027 F1833 B LHG Den- W.np Calc = MJ8 Frort Door faces: W
2018-Aug-15 09:51:59
Page 8
�
i
7225 S
i
I ■
I
Total
Total
Static Pressure and Friction Rate Job: F1833 B LHG Den
ghtsoft® Date: 05/14/2018
Entire House By- xF/Ri/MC/LF
One Stop Cooling and Heating
Coot, Wirier Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopCoolirg.com Licerse: CAC032444
For: Ryan Homes
Heating
Cooling
(in H2O)
(in H2O)
al static pressure
0.50
0.50
Ire losses
coil
0
0
Heat exchanger
0
0
Supply diffusers
0.03
0.03
Return grilles
0.03
0.03
Filter
0.10
0.10
Humidifier
0
0
Balancing damper
0
0
Other device
0
0
)le static pressure 0.34 0.34
Supply
Return
(ft)
(ft)
length of run -out
9
0
length of trunk
20
0
length of fittings
120
0
1
149
0
ive length
149
Heating
Cooling
(in/100ft)
(in/100ft)
Ducts 0.228 > 0.18
0.228 > 0.18
Ducts 0.228 > 0.18
0.228 > 0.18
4XQ5,11 A=20,11 G=5,11 G=5,11 G=5,1 AQ5,11 G=5,11 G=5,11 Gam: Total EL=120
Total ELF
+� wrightsoft®
Right-Sute®Uriversal201818.0.19RSU23249
or\Desldop\TEMP\Lot 027 F1833 B LHG Den- W.rtp Calc = W8 Frort Door faces: W
2018-Aug-I5 09:52:00
Page 1
Lghtsofts Duct System Summary
Entire House
One Stop Cooling and Heating
7225 Sa#cove Coot, Wirter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopCooling.com Licerse: CAC032444
For:
Extem static pressure
Press4e losses
Avail le static pressure
Sup pl ;% return available pressure
Lowe [fiction rate
Actual - irflow
Total eective length (TEL)
Ryan Homes
Heating
0.50
in H2O
0.16
in H2O
0.34
in H2O
0.170 / 0.170
in H2O
0.228
in/100ft
0
Cfm
149 ft
- Job: F1833 B LHG Den
Date: 05/14/2018
By: XF/RI/MULF
Cooling
0.50 in H2O
0.16 in H2O
0.34 in H2O
0.170 / 0.170 in H2O
0.228 in/100ft
933 cfm
[
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Mat
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BED21
C 2297
0
103
0.291
6.0
Ox0
VIFx
12.0
105.0
st1
BED3'
c 1415
0
63
0.301
6.0
Ox0
VIFx
12.8
100.0
sti
BTM1
C 362
0
16
0.262
4.0
Ox0
VIFx
15.0
115.0
sti
DEN
C 2217
0
99
0.233
6.0
Ox 0
VIFx
36.2
110.0
st2
DIN
c 2566
0
115
0.231
6.0
Ox 0
MR
37.2
110.0
st2
GFrr
c 4406
0
197
0.228
8.0
Ox0
VIFx
29.2
120.0
st2
Ktr
c 2077
0
93
0.253
6.0
Ox 0
VIFx
24.6
110.0
st2
LAUN
C 959
0
43
0.466
4.0
Ox 0
VIFx
3.0
70.0
rMED
c 3737
0
167
0.230
7.0
Ox0
VIFx
32.8
115.0
st2
WTH
C 715
0
32
0.239
4.0
Ox0
VIFx
32.5
110.0
st2
mwl
C 128
0
6
0.249
4.0
Ox0
VIFx
26.8
110.0
st2
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Nil
Ia
Type
(Cfm)
(cfm)
FR
(fpm)
(in)
(in)
Material
Trunk
st2
PeakAVF
0
708
0.228
662
14.0
0 x 0
VinlAx
st1
PeakAVF
0
182
0.262
681
7.0
0 x 0
VinIFIX
Grille
Htg
Clg
TEL
Design
Ueloc
Diam
H x W
Stud/Joist
Duct
Name'
Size (in)
(cfm)
(cim)
(ft)
FR
(fpm)
(in)
(in)
Opening (in)
Mat
Trunk
rb1
I Ox 0
0
933
0
0
0
0
Ox 0
VIFx
ffl
Job#: F1833 B LHG Den
Performed by XF/RI for:
Ryan Homes
Port St Lude, FL
Level 1
AC PADS SYGC MIN SIZE
40'='
W SEPARATION
16' OFF WAIL
' PVC RE=RIG LINECH BY
GC
One Stop Cooling and Heating
7225 Sandscove Court
Winter Park, FL 32792
Phone: (407) 629 - 6920 Fax: (407) 629 - 9307
www.OneStopCooling.com
EF1 = 50 CFM Fan
EF2 = 80 CFM Fan
EF3 =110 CFM Fan
EFL1 = 50 CFM Fan
EFL2 = 80 CFM Fan
EFL3 =110 CFM Fan
VTR = Vent to Roof
VTW = Vent to Wall
DV = Dryer Vent
RV = Range Vent
— — = Lineset Chase
- - = Condensate
O= Thermostat 18/8
SRB = Small Reduction Box
LRB = Large Reduction Box
FBB = Feld Built Box
Scale: 1 : 33
Page 1
Rot-c4A& U*ersa12D18
I&O.OB RSU182(2
2DI8Fdj-251201:42