HomeMy WebLinkAboutD O H SEWAGE TREATMENT SYSTEM - FINAL APPROVALi
RECEIVED
AGENT:
STATE OF FLORIDA APR .2 9 ?n1q
DEPARTMENT OF HEALTH p "I. tin Deparim,F
ONSITE SEWAGE TREATMENT gjPj$AL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
: Kenneth Williams
Construction
APPLICATION #:AP1356815
PERMIT #:56-SF-1865555
DOCUMENT #:F11282549
DATE PAID:07/25/2018
FEE PAID :51 5.00
RECEIPT #:56-PID-3626319
PROPERTY
ADDRESS: 17701 Wa onwheel Ln Fort Pierce, FL 34947�9:-l!V(�Y��
LOT: 7
BLOCK:g
LLg
Lud,e county
SUBDI VI
ION:
i9
ID# : 3211-701-0009-000-2
gill
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED,
(TANK INSTALLATION
SETBACKS
[ ]
[011
TANK SIZE [1] 1537.00 [21 483.00 [ ]
[271
SURFACE WATER FT
[ ]
1023
TANK MATERIAL Polypropylene [ l
[28I
DITCHES FT
[ ]
(03]
OUTLET DEVICE [ ]
[291
PRIVATE WELLS 92 FT
[ ]
1041
MULTI -CHAMBERED [ L�jj N I [ ]
[301
PUBLIC WELLS FT
[ ]
[05]
OUTLET FILTER Polylok PL-68 [ 1
[311
IRRIGATION WELLS 86 FT
[ 1
�[061
LEGEND 1. 70-143-16DC4 2. 70-143-54SC4 [ ]
[321
POTABLE WATER 80 FT
[ ]
1071
WATERTIGHT [ ]
[331
BUILDING FOUNDATIONS 9 FT,
[ ]
081
LEVEL [ ]
[341
PROPERTY LINES 100 FT
[ ]
091
DEPTH TO LID [ ]
[35I
OTHER FT
DRAINFIELD INSTALLATION
FILLED / MOUND SYSTEM
[ I
ii
[101
.AREA [1] 769.76 [21 SQFT [ ]
[361
DRAINFIELD COVER
[ ]
111
DISTRIBUTION BOX HEADER X [ I
[371
SHOULDERS
[ ]
121
NUMBER OF DRAINLINES 1, 6.00 2, [ ]
[38I
SLOPES
[ ]
1131
DRAINLINE SEPARATION [ ]
[391
STABILIZATION 04/26/2019
[ I
11141
DRAINLINE SLOPE
[ ]
I
153
DEPTH OF COVER
ADDITIONAL INFORMATION
[ ]
��l 6I
ELEVATION [ ABOVE / BELOW IBM 5,00 [ I
[401
UNOBSTRUCTED AREA
[ I
171
SYSTEM LOCATION [ ]
[411
STORMWATER RUNOFF
[ ]
183
DOSING PUMPS 1.00 [ l
[42I
ALARMS
[ ]
[191
AGGREGATE SIZE [ ]
[431
MAINTENANCE AGREEMENT
[ l
[1201
AGGREGATE EXCESSIVE FINES [ ]
1441
BUILDING AREA
[ I
[21]
AGGREGATE DEPTH [ ]
[451
LOCATION CONFORMS WITH SITE PLAN
/ MATERIAL [ ]
EXCAVATVATION ON
[46I
FINAL SITE GRADING
TILL
[ ]
[473
CONTRACTOR MICHAEL W STUHR (ASHTO
( ]
FILL AMOUNT
[ ]
[48]
OTHER INFILTRATOR Quick4 Plus EQ36 LP
( 1
221
FILL TEXTURE
[ ]
I241
EXCAVATION DEPTH
ABANDONMENT
[ ]
251
AREA REPLACED [ l
[491
TANK PUMPED
[ ]
i261
REPLACEMENT MATERIAL [ ]
[50]
TANK CRUSHED & FILLED
Commend:
Comments are on,page 2.
/
St. Lucie cHD DATE: 02/07/2019
CONSTRUCITION
[ APPROVED
DISAPPROVED ]' Env n tal Specialist II Brla
ngram (ENVIRONMENTAL HEALTH)
FINAL S
TEM
[ /
St. Lucie CHD DATE: 04/26/2019
APPROVED DISAPPROVED ] :
Env rontnental Specialist II Brl
J Ingram (ENVIRONMENTAL HEALTH)
(Explanation
of
Violations on following page)
DH 4016I
08/09
(Obsoletes all previous editions which may not be used)
Page 2 of 3
Incorporated:
64E-6.003, FAC
EH Database v 1.0.1 AP1356815
EID1865665
Comment
i
The sy
gpd.
New ST,
onsite. N
Final sys
I
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
Comment
APPLICATION #:AP1356815
PERMIT #:56-SF-1865555
DocubwNT #: F11282549
DATE PAID:07/25/2018
FEE PAID :51 5.00
RECEIPT #:56-PID-3626319
is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 460
t filter, DT, liberty 1/3 hp pump, and 4x11+2x12 long DF. No violations, system ok to cover. Contractor notified
final inspection for mound system, alarm check, and final site grading.
IDDroved. Contractor and building department emailed final approval.
DH 4016,,'08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC
V EH Database v 1.0.1 AP1356815
EID1866665
� Ip
Page 2 of 3