Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEL FORM IR405-2017 FLO IDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Fl,llrida Department of Business and Professional Regulation - Residential Performance Method Project Nllame: 17701 Wagon Wheel Ln Builder Name: DiFrancesco Construction Qq�o J Street: 17701 Wagon Wheel Ln Permit Office: St Lucie y� /t City, Sta e, Zip: Fort Pierce , FL , Permit Number: owner: Kenneth Williams Jurisdiction: 611000 �® LO Design LI cation: FL, ST LUCIE_CO_INTL County:: St. Lucie (Florida Climate Zone 2) ff 1. New construction or existing New (From Plans) 9. Wall Types (2976.3 sqft.) Insulation Area ' 2. Single f ,1 imily or multiple family Single-family a. Concrete Block - Polystyrene Bead AggrR=0.0 2633.00 W b. Frame -Wood, Adjacent R=13.0 343.33 ft' 1. Numbeiilof units, if multiple family 1 c. N/A R= ftz 4. Numbed of Bedrooms 4 d. N/A R= 10. Ceiling Types (3379.0 sqft.) Insulation Area 5. Is this a rvorst case? No a. Roof Deck (Unvented) R=20.0 3379.00 ft' 6. Conditioned floor area above grade (ft) 3379 b. N/A R= ftz CondfidlIhed floor area below grade (ftz) 0 R 11 Ducts R ftz 7. Windov's(519.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 675.8 a. U-Fa tor: Dbl, U=0.29 319.75 ftz SHG b. U-Fa D : SHGC=0.21 tor: Dbl, U=0.34 144.00 ftz 12. Cooling systems kBtu/hr Efficiency SHG SHGC=0.19 a. Central Unit 54.0 SEER:19.00 c. U-Fa tor: Dbl, U=0.26 30.00 ftz SHG : SHGC=0.21 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 26.00 ftz a. Electric Strip Heat 34.0 COP:1.00 SHG other (see details) Area W 'ighted Average Overhang Depth: 9.250 ft. Area W • Average SHGC: 0.224 14. Hot water systems IeIighted Area a. Propane Tankless Cap: 1 gallons 8. FloorTIpes (3379.0 sqft.) Insulation EF: 0.590 a. Slab- „n-Grade Edge Insulation R=0.0 3379.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= fF 15. Credits CF, Pstat Glass/FI Total Proposed Modified Loads: 102.59 or Area: 0.154 PASS Total Baseline Loads: 109.69 Il I hereby grtify that the plans and specifications covered by Review of the plans and O�THE S7`1T� this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance ��;� �O with the Florida Energy Code. rnu,�,�,,% • ;;:� . PREPA D BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as design is in compliance Florida Statutes. with the F�AGENT:74/�-& rida Eney Cde OD WE' OWNERBUILDING OFFICIAL: - - J7 DATE: DATE: - Compli I nce requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Comp li °nce requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelopelleakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 9/18/201 4:45 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 F(1RhA Rd L _7(117 PROJECT Title: Building Owner # of Units: Builder IS Permit Office: Jurisdiction: Family T'lpe: New/Exilbng: Comme Tiype: ame: lame: lt: II 17701 Wagon Wheel Ln Bedrooms: 4 User Conditioned Area: 3379 Kenneth Williams Total Stories: 1 1 Worst Case: No DiFrancesco Construction Rotate Angle: 0 St Lucie Cross Ventilation: 611000 Whole House Fan: Single-family New (From Plans) Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Street Address 17701 Wagon Wheel Ln St. Lucie Fort Pierce , FL, I CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range F I, ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Numb °r Name Area Volume 1 Blockl 3379 34465.8 SPACES Numbr Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 3379 34465.8 Yes 5 4 1 Yes Yes Yes 11 FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 305 ft 0 3379 ftz ---- 0 0 1 ROOF / V # Roof Gable Roof Type Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 3660 ftz 0 ftz Unfinishe 0.35 No 0.4 No 20 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 3379 ftz N N CEILING # CeilingType YP Space R-Value Ins Type Area Framing Frac Truss Type P YP 9 YP 1 Under Attic (Unvented) Main 0 Blown 3379 ftz 0 Wood 9/18/20�.',8 4:45 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 GnRnn Rd i �,_7n�7 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space Et In Et In Area RNA- Fraction Ahqor Gradp% _ 1 N Exterior Concrete Block - Polystyren Main 0 62 6 10 625.0 ft2 0 0 0.75 0 2 E Exterior Concrete Block - Polystyren Main 0 32 10 320.0 ft2 0 0 0.75 0 3 E Exterior Concrete Block - Polystyren Main 0 28 4 10 283.3 ft' 0 0 0.75 0 _ 4 NE Exterior Concrete Block - Polystyren Main 0 9 10 90.0 ft2 0 0 0.75 0 _ 5 SE Exterior Concrete Block - Polystyren Main 0 4 10 40.0 ft2 0 0 0.75 0 _ 6 S Exterior Concrete Block - Polystyren Main 0 60 10 600.0 ft2 0 0 0.75 0 •_ 7 S Exterior Concrete Block - Polystyren Main 0 14 4 10 143.3 ft2 0 0 0.75 0 _ 8 SW Exterior Concrete Block - Polystyren Main 0 5 10 50.0 ft2 0 0 0.75 0 9 NW Exterior Concrete Block - Polystyren Main 0 5 10 50.0 ft2 0 0 0.75 0 10 W Exterior Concrete Block - Polystyren Main 0 18 4 10 183.3 ft2 0 0 0.75 0 11 W Exterior Concrete Block - Polystyren Main 0 20 8 12 248.0 ft2 0 0 0.75 0 _ 12 N Garage Frame - Wood Main 13 9 10 90.0 ft2 0 0 0.75 0 13 W Garage Frame - Wood Main 13 25 4 10 253.3 ft2 0 0 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated Main None .21 3 8 24 ft2 2 W Insulated Main None .21 6 8 48 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V 1# Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.29 0.21 Y 45.0 ft2 2 ft 0 in 1 ft 0 in None None 2 N 1 Vinyl Low-E Double Yes 0.26 0.21 Y 6.0 ft2 2 ft 0 in 1 ft 0 in None None 3 E 2 Vinyl Low-E Double Yes 0.29 0.21 Y 22.8 ft2 2 ft 0 in 1 ft 0 in None None 4 E 3 Vinyl Low-E Double Yes 0.29 0.21 Y 45.0 f12 12 ft 0 in 1 ft 0 in None None 5 E 3 Vinyl Low-E Double Yes 0.29 0.21 Y 96.0 ft2 12 ft 0 in 1 ft 0 in None None 6 NE 4 Vinyl Low-E Double Yes 0.34 0.19 Y 48.0 ft2 12 ft 0 in 1 ft 0 in None None 7 SE 5 Vinyl Low-E Double Yes 0.29 0.21 Y 15.0 ft2 12 ft 0 in 1 ft 0 in None None 8 S 6 Vinyl Low-E Double Yes 0.34 0.19 Y 48.0 ft2 2 ft 0 in 1 ft 0 in None None 9 S 7 Vinyl Low-E Double Yes 0.34 0.19 Y 48.0 ft2 38 ft 0 in 1 ft 0 in None None 10 S 6 Vinyl Low-E Double Yes 0.29 0.21 Y 30.0 ft2 2 ft 0 in 1 ft 0 in None None 1 SW 8 None Glazed Block No 0.6 0.6 N 8.0 ft2 2 ft 0 in 1 ft 0 in None None 12 NW 9 None Glazed Block No 0.6 0.6 Y 8.0 ft2 2 ft 0 in 1 ft 0 in None None 13 W 10 None Glazed Block No 0.6 0.6 Y 10.0 ft2 2 ft 0 in 1 ft 0 in None None 14 W 11 Vinyl Low-E Double Yes 0.29 0.21 Y 36.0 ft2 2 ft 0 in 1 ft 0 in None None 15 W 11 Vinyl Low-E Double Yes 0.29 0.21 Y 30.0 ft2 2 ft 0 in 1 ft 0 in None None 1 16 W 11 Vinyl Low-E Double Yes 0.26 0.21 Y 24.0 ft2 2 ft 0 in 1 ft 0 in None None I 9/1812 18 4:45 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 I=r)PM Fla-,_7n17 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 628.904 ft2 628.904 ft2 66 ft loft 1 'll INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Whol (house Proposed ACH(50) .000324 2872.2 157.68 296.54 .243 5 •III HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 I, COOLING SYSTEM j # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None SEER: 19 54 kBtu/hr 1620 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane Tankless Exterior 0.59 1 gal 70 gal 120 deg None I SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ftz DUCTS ^ / # — Supply — — Return — Air CFM 25 CFM25 Location R-Value Area Location Area Leakage Type Handier TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 675.8 ft Attic 168.95 f Default Leakage Garage (Default) (Default) 1 1 911812Q18 4:45 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 TEMPERATURES Progra able Thermostat: Y Ceiling Fans: CoolingJan Heatin Jan Feb Feb [[ ]] Mar [Mar Apr pr [ [ ]May Ma [X] Jun [ ] Jun Jul Jul rl Au Au ri Se Sep rl Oct Oct Nov Nov HX [[ jj Dec [X) Dec Ventin Jan Feb [X Mar A r [ May [ ] Jun Jul Aug Se Oct Nov [[ ]] Dec ThermosO Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 i Cooling D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling EH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating D) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating EH) AM 66 66 66 66 66 68 68 68 68 68 68 68 III PM 68 68 68 68 68 68 68 68 68 68 66 66 9/18/2018 4:45 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 a III FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. 17701 Wagon Wheel Ln, Fort Pierce, FL, 1. New cohstruction or ebsting New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Polystyrene Bead AggtR=0.0 2633.00 1112 b. Frame - Wood, Adjacent R=13.0 343.33 ft2 3. Numbe of units, if multiple family 1 c. N/A R= ft2 4. Numbe of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this (worst case? No a. Roof Deck (Unvented) R=20.0 3379.00 f12 I 6. Conditil ined floor area (ft2) 3379 b. N/A R= ft2 7. Windo Its-- Description Area c. N/A R= ft2 11 •Ducts R ft2 a. U-F� tor: Dbl, U=0.29 319.75 ft2 it a. Sup: Attic, Ret: Attic, AH: Garage 6 675.8 SHICI: SHGC=0.21 b. U-F i.-tor: Dbl, U=0.34 144.00 ft2 SHGIC: SHGC=0.19 12. Cooling systems kBtu/hr Efficiency c. U-Fi tor: Dbl, U=0.26 30.00 ft2 a. Central Unit 54.0 SEER:19.00 SH C: SHGC=0.21 d. U-il'14ghted S. �Il,tor: other (see details) 26.00 ft2 13. Heating systems kBtu/hr Efficiency other (see details) Area(I a. Electric Strip Heat 34.0 COP:1.00 Average Overhang Depth: 9.250 ft. Area Wleighted Average SHGC: 0.224 8. Floor TII es Insulation Area 14. Hot water systems Cap: 1 gallons a. Slab -On -Grade Edge Insulation R=0.0 3379.00 ft2 a. Propane EF: 0.59 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 15. Credits CF, Pstat I certifytat this home has complied with the Florida Energy Efficient Code for Building p 9Y Y 9 Construct o�S1ttESI.q�8 bn through the above energy saving features which will be installed (or exceeded) in this hor p e before final inspection. Otherwise, a new EPL Display Card will be completed y4r°',,,, �� •_ =;,. �'� based on, ristalled Code compliant features. ,,,,, •:, t = �, �`'�, o Builder Si nature: �%�� Date: q_r b��g ``"-' f� Address New Home: -u b� M �, ,1! )4G=X 1 y� City/FL Zip: Wis'l���� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mort 11 age (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at tech iII pport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certif ad Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Com'�nission's support staff. La 'el required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/1 . /2018 4:46 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 FORM 7 Envelope Leakage Test Report Performance Project Street: City, St Design Cond. F .E C: FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Performance Method ne: 17701 Wagon Wheel Ln 17701 Wagon Wheel Ln Zip: Fort Pierce, FL , ation: FL, ST_LUCIE_CO_INTL Area:: 3379 sq.ft. pe Leakage Test Results m Data: n: Sinole br Multi Point Test Data N. Builder Name: DiFrancesco Construction Permit Office: St Lucie Permit Number: Jurisdiction: 611000 Cond. Volume: 34466 cu ft. HOUSE PRESSURE FLOW: 1 Pa cfm 2 Pa cfm 3 Pa cfm 4 Pa cfm 5 Pa cfm 6 Pa cfm Leakage Characteristics Required ACH(50) from FORM R405-2017 : Tested ACH(50) * : *Tested leakage must be less than or equal to the required ACH(50) shown on Form R405-2017 for this building. If the tested ACH(50) is less than 3 the building must have a mechanical ventilation system. R402.4111.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate ones 1 and 2 ... Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third parfl. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performald at any time after creation of all penetrations of the building thermal envelope. D�ullllring testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures; 3. Interior doors, if installed at the time of the test, shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and 6. Supply and return registers, if installed at the time of the test, shall be fully open. I herel"y certify that the above envelope leakage perfor Lance results demonstrate compliance with Florida Energy Code requirements in accorl nce with Section R402.4.1.2. NAME: Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the third party conducting the test and provided to the code official. BUILDING OFFICIAL: DATE: 8 4.46 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1