Fl,llrida Department of Business and Professional Regulation - Residential Performance Method
Project Nllame:
17701 Wagon Wheel Ln Builder Name: DiFrancesco Construction Qq�o
J
Street:
17701 Wagon Wheel Ln Permit Office: St Lucie y�
/t
City, Sta
e, Zip: Fort Pierce , FL , Permit Number:
owner:
Kenneth Williams Jurisdiction: 611000 �®
LO
Design LI
cation: FL, ST LUCIE_CO_INTL County:: St. Lucie (Florida Climate Zone 2) ff
1. New construction
or existing New (From Plans)
9. Wall Types (2976.3 sqft.) Insulation Area
'
2. Single f
,1
imily or multiple family Single-family
a. Concrete Block - Polystyrene Bead AggrR=0.0 2633.00 W
b. Frame -Wood, Adjacent R=13.0 343.33 ft'
1. Numbeiilof
units, if multiple family 1
c. N/A R= ftz
4. Numbed
of Bedrooms 4
d. N/A R=
10. Ceiling Types (3379.0 sqft.) Insulation Area
5. Is this a
rvorst case? No
a. Roof Deck (Unvented) R=20.0 3379.00 ft'
6. Conditioned
floor area above grade (ft) 3379
b. N/A R= ftz
CondfidlIhed
floor area below grade (ftz) 0
R
11 Ducts R ftz
7. Windov's(519.8
sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage 6 675.8
a. U-Fa
tor: Dbl, U=0.29 319.75 ftz
SHG
b. U-Fa
D : SHGC=0.21
tor: Dbl, U=0.34 144.00 ftz
12. Cooling systems kBtu/hr Efficiency
SHG
SHGC=0.19
a. Central Unit 54.0 SEER:19.00
c. U-Fa
tor: Dbl, U=0.26 30.00 ftz
SHG
: SHGC=0.21
13. Heating systems kBtu/hr Efficiency
d. U-Factor:
other (see details) 26.00 ftz
a. Electric Strip Heat 34.0 COP:1.00
SHG
other (see details)
Area W
'ighted Average Overhang Depth: 9.250 ft.
Area W
•
Average SHGC: 0.224
14. Hot water systems
IeIighted
Area
a. Propane Tankless Cap: 1 gallons
8. FloorTIpes
(3379.0 sqft.) Insulation
EF: 0.590
a. Slab-
„n-Grade Edge Insulation R=0.0 3379.00 ftz
b. Conservation features
b. N/A
R= ftz
None
c. N/A
R= fF
15. Credits CF, Pstat
Glass/FI
Total Proposed Modified Loads: 102.59
or Area: 0.154 PASS
Total Baseline Loads: 109.69
Il
I hereby
grtify that the plans and specifications covered by
Review of the plans and O�THE S7`1T�
this calculation
are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
��;� �O
with the Florida Energy Code. rnu,�,�,,% • ;;:� .
PREPA
D BY:
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby certify
that this building, as design is in compliance
Florida Statutes.
with the F�AGENT:74/�-&
rida Eney Cde
OD WE'
OWNERBUILDING
OFFICIAL:
- - J7
DATE:
DATE:
- Compli I nce requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Comp li °nce requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelopelleakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
9/18/201 4:45 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
F(1RhA Rd L
_7(117
PROJECT
Title:
Building
Owner
# of Units:
Builder IS
Permit Office:
Jurisdiction:
Family T'lpe:
New/Exilbng:
Comme
Tiype:
ame:
lame:
lt:
II
17701 Wagon Wheel Ln Bedrooms: 4
User Conditioned Area: 3379
Kenneth Williams Total Stories: 1
1 Worst Case: No
DiFrancesco Construction Rotate Angle: 0
St Lucie Cross Ventilation:
611000 Whole House Fan:
Single-family
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
17701 Wagon Wheel Ln
St. Lucie
Fort Pierce ,
FL,
I
CLIMATE
V
Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
F
I, ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90
70
75 299
58 Medium
BLOCKS
Numb
°r
Name
Area Volume
1
Blockl
3379 34465.8
SPACES
Numbr
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
3379 34465.8 Yes 5
4
1 Yes
Yes Yes
11
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
Main 305 ft 0
3379 ftz
----
0 0 1
ROOF
/
V
#
Roof Gable Roof
Type Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip
Metal 3660 ftz 0 ftz Unfinishe
0.35
No 0.4
No 20 22.6
ATTIC
V
#
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented 0 3379 ftz
N N
CEILING
#
CeilingType
YP
Space R-Value Ins Type Area Framing Frac Truss Type
P YP 9 YP
1
Under Attic (Unvented)
Main 0 Blown
3379 ftz 0
Wood
9/18/20�.',8 4:45 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
GnRnn Rd i �,_7n�7
WALLS
Adjacent
Cavity
Width
Height
Sheathing
Framing
Solar
Below
Space
Et
In
Et
In
Area
RNA-
Fraction
Ahqor
Gradp%
_ 1
N
Exterior
Concrete Block - Polystyren Main
0
62
6
10
625.0 ft2
0
0
0.75
0
2
E
Exterior
Concrete Block - Polystyren Main
0
32
10
320.0 ft2
0
0
0.75
0
3
E
Exterior
Concrete Block - Polystyren Main
0
28
4
10
283.3 ft'
0
0
0.75
0
_ 4
NE
Exterior
Concrete Block - Polystyren Main
0
9
10
90.0 ft2
0
0
0.75
0
_ 5
SE
Exterior
Concrete Block - Polystyren Main
0
4
10
40.0 ft2
0
0
0.75
0
_ 6
S
Exterior
Concrete Block - Polystyren Main
0
60
10
600.0 ft2
0
0
0.75
0
•_ 7
S
Exterior
Concrete Block - Polystyren Main
0
14
4
10
143.3 ft2
0
0
0.75
0
_ 8
SW
Exterior
Concrete Block - Polystyren Main
0
5
10
50.0 ft2
0
0
0.75
0
9
NW
Exterior
Concrete Block - Polystyren Main
0
5
10
50.0 ft2
0
0
0.75
0
10
W
Exterior
Concrete Block - Polystyren Main
0
18
4
10
183.3 ft2
0
0
0.75
0
11
W
Exterior
Concrete Block - Polystyren Main
0
20
8
12
248.0 ft2
0
0
0.75
0
_ 12
N
Garage
Frame - Wood Main
13
9
10
90.0 ft2
0
0
0.75
0
13
W
Garage
Frame - Wood Main
13
25
4
10
253.3 ft2
0
0
0.75
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Insulated Main
None
.21
3
8
24 ft2
2
W
Insulated Main
None
.21
6
8
48 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
1#
Omt ID
Frame Panes NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1
Vinyl Low-E Double Yes
0.29
0.21
Y
45.0 ft2
2 ft 0 in
1 ft 0 in
None
None
2
N 1
Vinyl Low-E Double Yes
0.26
0.21
Y
6.0 ft2
2 ft 0 in
1 ft 0 in
None
None
3
E 2
Vinyl Low-E Double Yes
0.29
0.21
Y
22.8 ft2
2 ft 0 in
1 ft 0 in
None
None
4
E 3
Vinyl Low-E Double Yes
0.29
0.21
Y
45.0 f12
12 ft 0 in
1 ft 0 in
None
None
5
E 3
Vinyl Low-E Double Yes
0.29
0.21
Y
96.0 ft2
12 ft 0 in
1 ft 0 in
None
None
6
NE 4
Vinyl Low-E Double Yes
0.34
0.19
Y
48.0 ft2
12 ft 0 in
1 ft 0 in
None
None
7
SE 5
Vinyl Low-E Double Yes
0.29
0.21
Y
15.0 ft2
12 ft 0 in
1 ft 0 in
None
None
8
S 6
Vinyl Low-E Double Yes
0.34
0.19
Y
48.0 ft2
2 ft 0 in
1 ft 0 in
None
None
9
S 7
Vinyl Low-E Double Yes
0.34
0.19
Y
48.0 ft2
38 ft 0 in
1 ft 0 in
None
None
10
S 6
Vinyl Low-E Double Yes
0.29
0.21
Y
30.0 ft2
2 ft 0 in
1 ft 0 in
None
None
1
SW 8
None Glazed Block No
0.6
0.6
N
8.0 ft2
2 ft 0 in
1 ft 0 in
None
None
12
NW 9
None Glazed Block No
0.6
0.6
Y
8.0 ft2
2 ft 0 in
1 ft 0 in
None
None
13
W 10
None Glazed Block No
0.6
0.6
Y
10.0 ft2
2 ft 0 in
1 ft 0 in
None
None
14
W 11
Vinyl Low-E Double Yes
0.29
0.21
Y
36.0 ft2
2 ft 0 in
1 ft 0 in
None
None
15
W 11
Vinyl Low-E Double Yes
0.29
0.21
Y
30.0 ft2
2 ft 0 in
1 ft 0 in
None
None
1
16
W 11
Vinyl Low-E Double Yes
0.26
0.21
Y
24.0 ft2
2 ft 0 in
1 ft 0 in
None
None
I
9/1812 18 4:45 PM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 3 of 5
I=r)PM Fla-,_7n17
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
628.904 ft2
628.904 ft2
66 ft loft 1
'll
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Whol
(house
Proposed ACH(50)
.000324
2872.2 157.68 296.54 .243 5
•III
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
Electric Strip Heat/
None
COP:1 34 kBtu/hr 1
sys#1
I,
COOLING SYSTEM
j #
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
None
SEER: 19 54 kBtu/hr 1620 cfm 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Propane Tankless
Exterior
0.59 1 gal 70 gal 120 deg None
I
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ftz
DUCTS
^ /
#
— Supply — — Return — Air CFM 25 CFM25
Location R-Value Area Location Area Leakage Type Handier TOT OUT QN RLF
HVAC #
Heat Cool
1
Attic 6 675.8 ft Attic
168.95 f Default Leakage Garage (Default) (Default)
1 1
911812Q18 4:45 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
TEMPERATURES
Progra
able Thermostat: Y
Ceiling Fans:
CoolingJan
Heatin
Jan
Feb
Feb
[[ ]] Mar
[Mar
Apr
pr
[
[
]May
Ma
[X] Jun
[ ] Jun
Jul
Jul
rl
Au
Au
ri
Se
Sep
rl
Oct
Oct
Nov
Nov
HX
[[ jj Dec
[X) Dec
Ventin
Jan
Feb
[X Mar
A r
[
May
[ ] Jun
Jul
Aug
Se
Oct
Nov
[[ ]] Dec
ThermosO
Schedule:
HERS 2006 Reference
Hours
Schedule
Type
1
2
3
4
5
6
7
8
9
10
11
12
i
Cooling
D)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling
EH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating
D)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating
EH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
III
PM
68
68
68
68
68
68
68
68
68
68
66
66
9/18/2018 4:45 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
a III
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the EnergyPerformance Index, the more efficient the home.
17701 Wagon Wheel Ln, Fort Pierce, FL,
1. New cohstruction
or ebsting New (From Plans) 9. Wall Types Insulation Area
2. Single
family or multiple family Single-family a. Concrete Block - Polystyrene Bead AggtR=0.0 2633.00 1112
b. Frame - Wood, Adjacent R=13.0 343.33 ft2
3. Numbe
of units, if multiple family 1 c. N/A R= ft2
4. Numbe
of Bedrooms 4 d. N/A R= ft2
10. Ceiling Types Insulation Area
5. Is this
(worst case? No a. Roof Deck (Unvented) R=20.0 3379.00 f12
I
6. Conditil
ined floor area (ft2) 3379 b. N/A R= ft2
7. Windo
Its-- Description Area c. N/A R= ft2
11 •Ducts R ft2
a. U-F�
tor: Dbl, U=0.29 319.75 ft2
it a. Sup: Attic, Ret: Attic, AH: Garage 6 675.8
SHICI:
SHGC=0.21
b. U-F
i.-tor: Dbl, U=0.34 144.00 ft2
SHGIC:
SHGC=0.19 12. Cooling systems kBtu/hr Efficiency
c. U-Fi
tor: Dbl, U=0.26 30.00 ft2 a. Central Unit 54.0 SEER:19.00
SH
C: SHGC=0.21
d. U-il'14ghted
S.
�Il,tor: other (see details) 26.00 ft2
13. Heating systems kBtu/hr Efficiency
other (see details)
Area(I
a. Electric Strip Heat 34.0 COP:1.00
Average Overhang Depth: 9.250 ft.
Area Wleighted
Average SHGC: 0.224
8. Floor TII
es Insulation Area 14. Hot water systems
Cap: 1 gallons
a. Slab
-On -Grade Edge Insulation R=0.0 3379.00 ft2 a. Propane EF: 0.59
b. N/A
R= ft2
b. Conservation features
c. N/A
R= ft2
None
15. Credits CF, Pstat
I certifytat
this home has complied with the Florida Energy Efficient Code for Building
p 9Y Y 9
Construct
o�S1ttESI.q�8
bn through the above energy saving features which will be installed (or exceeded)
in this hor
p e before final inspection. Otherwise, a new EPL Display Card will be completed y4r°',,,, �� •_ =;,. �'�
based on,
ristalled Code compliant features. ,,,,, •:, t = �, �`'�, o
Builder Si
nature: �%�� Date: q_r b��g ``"-' f�
Address
New Home: -u b� M �, ,1! )4G=X 1 y� City/FL Zip:
Wis'l����
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mort 11 age (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
tech iII pport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certif ad Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Com'�nission's support staff.
La 'el required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
9/1 . /2018 4:46 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
FORM
7 Envelope Leakage Test Report Performance
Project
Street:
City, St
Design
Cond. F
.E
C:
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Performance Method
ne: 17701 Wagon Wheel Ln
17701 Wagon Wheel Ln
Zip: Fort Pierce, FL ,
ation: FL, ST_LUCIE_CO_INTL
Area:: 3379 sq.ft.
pe Leakage Test Results
m Data:
n:
Sinole br Multi Point Test Data
N.
Builder Name: DiFrancesco Construction
Permit Office: St Lucie
Permit Number:
Jurisdiction: 611000
Cond. Volume: 34466 cu ft.
HOUSE PRESSURE
FLOW:
1
Pa
cfm
2
Pa
cfm
3
Pa
cfm
4
Pa
cfm
5
Pa
cfm
6
Pa
cfm
Leakage Characteristics
Required ACH(50) from
FORM R405-2017 :
Tested ACH(50) * :
*Tested leakage must be less than or equal to the
required ACH(50) shown on Form R405-2017 for
this building. If the tested ACH(50) is less than 3
the building must have a mechanical ventilation
system.
R402.4111.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in
Climate ones 1 and 2 ... Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved
third parfl. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be
performald at any time after creation of all penetrations of the building thermal envelope.
D�ullllring testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other
infiltration control measures;
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration
control measures;
3. Interior doors, if installed at the time of the test, shall be open;
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and
6. Supply and return registers, if installed at the time of the test, shall be fully open.
I herel"y certify that the above envelope leakage
perfor Lance results demonstrate compliance
with Florida Energy Code requirements in
accorl nce with Section R402.4.1.2.
NAME:
Testing shall be conducted by either
individuals as defined in Section
553.993(5) or (7), Florida Statutes or
individuals licensed as set forth in
Section 489.105(3)(f), (g), or (i) or an
approved third party. A written report of
the results of the test shall be signed
by the third party conducting the test
and provided to the code official.
BUILDING OFFICIAL:
DATE:
8 4.46 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1