Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL - 1 INCH NAILSTRIP2160 SW Poma Drive Palm City, FL 34990 pliant with Florida Building Code 2017 (61" ed.) pliant with Florida Product Approval Rule#"611 pliant: Keystone Certifications IV ED SEP 19 ST. Lucie County, Permitting ct:1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507-4— Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.) Rib Height 1" ;ion Resistant Compliant: FBC Sec.1507.4.3 ter 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru n of support. ive/Sealant : Bostik 9151 Chem -Chalk one component, polyurethane adhesive with continuous bead application along base of male rib vertical flange at each panel To be compliant with FBC Sec 1507.1.1 : Shall be in compliance with FBC Sec.1507. Install Details: Table A Allowable Loads METHOD 1 METHOD 2 DESj,GN PRESSURE* -86 PSF Main field -97.25 PSF Perimeter FAStENER SPACING _ 6" O.C. 6" O.C. SEA ADHESIVE Not required 3/1V continuous bead L_.___._..-.... .. _....__...--- _ __.---- .................__..__. _. '..— _....... (.see det ails) Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2 EQUI ,ALENCY.• UL1897-04 is equivalent to Test Standard UL1897-12. *Design Pressure margin of safe 2:1 Ce icate of Independence: Bowden, P.E. does not have, not will acquire a financial i9jip!a3t4r# q9y company manufacturing or distributing products this evaluation. ������ D• Br} r���i, Bowden, P.E. is not owned, operated, or controllee#%M(A c�'IjmRi f {han c turer, or distributing products under this • • seal -Q •• STATE OF ; eci 1. , deriayment to be compliance with current Florida Building Code (FBC)2017 61h ed.. 2. IN inimum slope to be compliant with Florida Building Code 2017 6'h ed., and per with Manufacturer's installation reference. 3. ducts are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. E igineering analysis for"project specific approval by local authorities wrjurisdiction is allowed by other registered engineers. 5. F;re classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Pppport framing in Compliance w/FBC 2017 6t' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural 7. Tf �is report does not imply warranty, installation, recommended product use outside of this report. FL 17022.6 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details 16" 3/4" Panel Profile 16" o.c. 1� Deck: -15/32" or greater Plywood, or - Wood plank Integral Snap Lock For METHOD 2: Apply 3f16" Bead Bostik 915TM' Sealant Continuous Along Male Rib Vertical Flange Fastener #10 x 1" Min. per Table "A" Pancake Head Wood Screw (Typical Fastening Pattern Across Width) ill FL 17022.6 1.0 Nail Strip (26GA Steel),16" Wide Roof Panel - Details ==v15/k. or greater Plywood, or - Wood plank C.�cienc� Isometric View Apply 3116" Bead Bostik 915TM Sealant ContinuousAlong Male Rib Vertical Flange (Refer to Table "A")