Product Manufacturer 3 A TAYLOR ROOFING
Address/Phone/Email 302 Melton Drive
FT PIERCE, FL 34982
(772)466-4040
kylewhite228@aol.com
Authorized Signature Kyle Taylor
kylewhite228@aol.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
.r Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Locke Bowden
Evaluation Report
Florida License PE-49704
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 01/23/2023
Validated By Zachary R. Priest, P.E.
4' Validation Checklist - Hardcopy Received
Certificate of Independence
FL17443 R1 COI FL 17443 J A Taylor 2017 Code Eval Report with Details
RSSS.pi1f
Referenced Standard and Year (of Standard) Standard Year
TAS 125 2003
UL1897 2012
UL580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
01/24/2018
Date Validated
02/14/2018
Date Pending FBC Approval
02/17/2018
Date Approved
04/10/2018
FL # j !1,-Number or Name
_..1,..__.w._..._..... _............... ...............
17443.1 _............IL..-- . _........................
5 V Crimp
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-129.25
Other:-129.25 @ 6" o.c. -69.25 @16" o.c. margin of safety
2:1 with 24" max. coverage install per manufacturers detail.
Not for use in HVHZ.
17443.2 1 VICTORIAN CRIMP SHINGLE
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-105
Other:-105PSF margin of safety 2:1. Install per
manufacturer's details and in compliance with FBC 2017 6th
ed, Not for use in HVHZ.
Description
."--__...-..-.w..._-,................................ .I ...... .........
..._...._ ._.....,_................
26GA 1/2" rib height over 15/32" APA plywood
Installation Instructions
FL17443 R1 II FL 17443 3 A Taylor 2017 Code Eval Report
with Details RSSS.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17443 RI�AE FL 17443 3 A Taylor 24� 4ode Ey,31 Repg>
with Details RSSS.pdf
Created by Independent Third Party: Yes
26GA 1/2" RIB- PANELS LOCK INTO PREVIOUS PANELS; OVER
CDX/APA 15/32" PLYWOOD
Installation Instructions
FL17443 RI II FL 17443 3 A Taylor 2017 Code Eva, Repot
with Detalli.R55S.pd1
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17443 R1 AE FL 17443 1 A "raylor 2017 Code Eval Repor
with Details RSSS;,pdf
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee F1. 32399 Phone: 050.487-1824
The State of Florida is an AA/EEO employer. C�py,�ght 2007-2Q13 State of Florida.:: Prlvacv Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850,487,1395, 'Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012,, licensees licensed under Chapter 455, F.S. -must provide the Department with an email address If they have
one. The emaik provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter455, F.S„
please click here .
Product Approval Accepts;
M® check M
Credit Gard
Safe