BLOWER DOOR TEST FORS
House 1101krazion Test Certification �r�By �®
Pr eSCIFIFiive and Pert-Orbm@nce MVchad ag Lucie C®ujJgY
C ��� _ 063
Permit t.0 4
�✓ New cons€ructiol,, o Co � i
e, f ? �- 4
EAS—king —After er Addition
HousI§1 Infiltration Test Results
CFM �150) = 2 Z SLC Ornate Zone 2
Vol61 % e = `7 S 2, O '1 est Date: T7 Zb'I 2� z
ACH � 0) = CFM (5o) H GO / Volume = = •3
Passing
Mechanical Ventilarian regUired less than 3 ACF1
llresul`�s must be � ACF1(5O] or less
V Kass ( ) Fall
Fi3C, Er Iergy
The bu Idmg or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in �'Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section �553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (I) or an
approv Illd third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thernali envelope.
FEC, Residen;:iai
ilUhere'he air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressures of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Lmoany
Testing
Com pan i Name: Pro -Duct Services Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requiren cents in accordance with Section R402.4.1.2 Climate Zone 2.
I,
Signatur
Printed lame: Martin Klein
License/Certification##; 5061633