Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE - 7-26-19FORN R405-2017 FLOZrida 'IDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Department of Business and Professional Regulation - Residential Performance Method ,lame: i �,,FS Project AHMED RESIDENCE Builder Name: "j Street: 7875 SADDLEBROOK DRIVE Permit Office: ST LUCIE COUNTY "te, 2 6 City, St Zip: PORT ST LUCIE, FL, Permit Number: JUL 2019 Owner: Jurisdiction: ST LUCIE COUNTY Design location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Clim tqoropUnty, Permitting 1. New c instruction or existing New (From Plans) 9. Wall Types (6190.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=5.0 6190.00 ft2 IIr b. N/A R= ft2 3. Numb of units, if multiple family 1 c. N/A R= ft2 4. Numb IIr of Bedrooms 6 d. N/A R= ft2 10. Ceiling Types (7522.0 sqft.) Insulation Area 5. Is this a worst case? No il a. Roof Deck (Unvented) R=22.0 7522.00 ft2 6. Conditioned floor area above grade (ft2) 7522 b. N/A R= ft2 Condil toned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(888.3 sgft.) Description Area 2 additional duct system(s) 6 160 a. U- actor: Sgl, U=0.65 723.00 ft2 b. Sup: Attic, Ret: Attic, AH: AHU 2 6 120 SH C: SHGC=0.25 c. Sup: Attic, Ret: Attic, AH: AHU 3 (see details b. U-F actor: Sgl, U=0.70 165.33 ft2 12. Cooling systems kBtu/hr Efficiency SH C: SHGC=0.30 a. Central Unit 41.0 SEER:16.00 b. Central Unit 29.4 SEER:16.00 c. U_F factor: N/A ft2 2 additional cooling systems (see details) SHE C: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SH, C: b. Electric Strip Heat i27.0 COP:1.00 ApO g 2 heating ED details) Area `,eighted Average Overhang Depth: 2.000 ft. additional systems (see Area Weighted Average SHGC: 0.259 14. Hot water systems V 8. Floor I (7522.0 sqft.) Insulation Area a. Electric 99 Cap; 80 gallons �u�'id® Ca Cap; Hypes a. Sla On -Grade Edge Insulation R=0.0 4263.00 ft2 b. Conservation features b. Rai: ed Floor R=19.0 3259.00 ft2 None c. NIA R= ft2 15. Credits None I Glass/.I Total Proposed Modified Loads: 225.85 loo�Area: 0.118 PASS Total Baseline Loads: 226.29 I hereb certify that the plans and specifications covered by Review of the plans and Sx,4?A this cal ulation are in compliance with the Florida Energy OZKE specifications covered by this , s , .; O Code. calculation indicates compliance with the Florida Energy Code. PREP .. DATE: D-BY: -- Alsiblaki6m.0 Before construction is completed ` this building will be inspected for O " - -�� �``-- compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. 1 �� with the Florida Energy Code.- OWNgR/AGENT: BUILDING OFFICIAL: DATE: I DATE: - Com ` liance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certi fed factory -sealed in accordance with R403.3.2.1. - Com °liance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 9 10:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 i FnRnn IzanS_91117 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: AHMED RESIDENCE Bedrooms: 6 Address Type: Street Address Buildin' Type: User Conditioned Area: 7522 Lot# Owner Name: Total Stories: 1 Block/Subdivision: # of U its: 1 Worst Case: No PlatBook: Builde !Name: Rotate Angle: 0 Street: 7875 SADDLEBROOK Permit Office: ST LUCIE COUNTY Cross Ventilation: County: St. Lucie Jurisdi ition: ST LUCIE COUNTY Whole House Fan: City, State, Zip: PORT ST LUCIE, Family, l ype: Single-family FL, New/E sting: New (From Plans) Comm J nt: Ill CLIMATE v Design Temp Int Design Temp Heating Design Daily Temp Design Location i TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range L, ST_LUCIE _CO_INTL FL_VERO_BEACH _MUNI 39 90 70 75 299 58 Medium BLOCKS Nurr6er Name Area Volume 1 I Block1 2503 25030 2 Block2 1760 17600 3 I Block3 1701 17010 4 i Block4 1558 15580 ! i SPACES Nurnber Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 f AHU 1 2503 25030 Yes 0 1 1 Yes Yes Yes 2 l AHU 2 I 1760 17600 No 0 2 1 Yes Yes Yes 3 AHU 3 1701 17010 Yes 0 1 1 Yes Yes Yes 4 i AHU 4 1558 15580 No 0 2 1 Yes Yes Yes FLOORS l # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet l 1 Slab -On -Grade Edge Insulation AHU 1 187 ft 0 ii 2503 ft2 e__ 1 0 0 j 2 Slab -On -Grade Edge Insulation AHU 2 111 ft 0 1760 ft2 ---- 1 0 0 3 Raised Floor AHU 3 ____ ---_ 1701 ft2 19 1 0 0 i 4 Raised Floor AHU 4 _-_- ____ 1558 ft2 19 1 0 0 i ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) t 1 Hip Barrel tile 8148 ft2 0 ft2 Medium N 0.2 No 0.9 No 22 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 7522 ft2 N N I 7/23/ I019 10:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 i f r FORM � 05-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) AHU 1 0 Blown 2503 ft2 0.11 Wood 2 Under Attic (Unvented) AHU 2 0 Blown 1760 ft2 0.11 Wood i 3 Under Attic (Unvented) AHU 3 0 Blown 1701 ft2 0.11 Wood 4 i Under Attic (Unvented) AHU 4 0 Blown 1558 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 NE Exterior Concrete Block - Ext Insul AHU 1 5 54 10 540.0 ft2 0 0 0.2 0 2 SE Exterior Concrete Block - Ext Insul AHU 1 5 29 10 290.0 ft2 0 0 0.2 0 3 SW Exterior Concrete Block - Ext Insul AHU 1 5 45 10 450.0 ft2 0 0 0.2 0 4 NW Exterior Concrete Black - Ext Insul AHU 1 5 69 10 690.0 ft2 0 0 0.2 0 5 I NE Exterior Concrete Block - Ext Insul AHU 2 5 9 10 90.0 ft2 0 0 0.2 0 6 SE Exterior Concrete Block - Ext Insul AHU 2 5 51 10 510.0 ft2 0 0 0.2 0 7 SW Exterior Concrete Block - Ext Insul AHU 2 5 40 10 400.0 ft2 0 0 0.2 0 8 NW Exterior Concrete Block - Ext Insul AHU 2 5 11 10 110.0 ft2 0 0 0.2 0 9 j NE Exterior Concrete Block - Ext Insul AHU 3 5 38 10 380.0 ft2 0 0 0.2 0 10 SE Exterior Concrete Block - Ext Insul AHU 3 5 19 10 190.0 ft2 0 0 0.2 0 _ 11 SW Exterior Concrete Block - Ext Insul AHU 3 5 45 10 450.0 ft2 0 0 0.2 0 12 NW Exterior Concrete Block - Ext Insul AHU 3 5 59 10 590.0 ft2 0 0 0.2 0 13 NE Exterior Concrete Block - Ext Insul AHU 4 5 47 10 470.0 ft2 0 0 0.2 0 14 SE Exterior Concrete Block - Ext Insul AHU 4 5 52 10 520.0 ft2 0 0 0.2 0 15 j SW Exterior Concrete Block - Ext Insul AHU 4 5 40 10 400.0 ft2 0 0 0.2 0 16 NW Exterior Concrete Block - Ext Insul AHU 4 5 11 10 110.0 ft2 0 0 0.2 0 i DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NW Insulated AHU 1 None .17 2 8 8 21.3 ft2 2 NE Insulated AHU 2 None .17 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang �/ # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 1 Metal Low-E Single Yes 0.65 0.25 Y 60.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE 1 Metal Low-E Single Yes 0.65 0.25 Y 16.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 3 NE 1 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 4 NE 1 Metal Low-E Single Yes 0.7 0.3 Y 48.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 5 SE 2 Metal Low-E Single Yes 0.7 0.3 Y 24.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 6 SE 2 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 I 7 SE 2 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 8 SW 3 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 9 SW 3 Metal Low-E Single Yes 0.65 0.25 Y 12.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 10 SW 3 Metal Low-E Single Yes 0.65 0.25 Y 6.0 ft2 2 It 0 in 1 ft 4 in Drapes/blinds Exterior 5 I I i I i 7/23/2 i i I 19 10.55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 Pr)PRA Ing-qn`17 INPI IT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 11 SW 3 Metal Low-E Single Yes 0.65 0.25 Y 16.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 12 NW 4 Metal Low-E Single Yes 0.65 0.25 Y 60.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 13 NW 4 Metal Low-E Single Yes 0.65 0.25 Y 24.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 i 14 SE 6 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 15 SE 6 Metal Low-E Single Yes 0.65 0.25 Y 6.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 16 SE 6 Metal Low-E Single Yes 0.65 0.25 Y 12.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 17 SW 7 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 18 SW 7 Metal Low-E Single Yes 0.65 0.25 Y 12.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 19 NW 8 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 20 SW 7 Metal Low-E Single Yes 0.7 0.3 Y 48.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 21 NW 8 Metal Low-E Single Yes 0.7 0.3 Y 21.3 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 i 22 NE 9 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 23 NE 9 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 24 SE 10 Metal Low-E Single Yes 0.7 0.3 Y 24.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 25 SE 10 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 j 26 SW 11 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 27 SW 11 Metal Low-E Single Yes 0.65 0.25 Y 16.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 i 28 NW 12 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 29 NW 12 Metal Low-E Single Yes 0.65 0.25 Y 8.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 30 NE 13 Metal Low-E Single Yes 0.65 0.25 Y 90.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 31 SE 14 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 32 SW 15 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 i 33 SW 15 Metal Low-E Single Yes 0.65 0.25 Y 60.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 i 34 I NW 16 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 i INFILTRATION # cope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wt II lehouse Proposed ACH(50) .000445 8775.7 481.77 906.04 .1685 7 HEATING SYSTEM V !11# System Type Subtype Efficiency Capacity Block Ducts i 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COPA 27 kBtu/hr 2 sys#2 3 Electric Strip Heat/ None COP:1 27 kBtu/hr 3 sys#3 4 Electric Strip Heat/ None COP:1 27 kBtu/hr 4 sys#4 9 10:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 r=nRnn RI nF_gn17 IMP[ IT S[IMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None SEER: 16 41 kBtu/hr 1230 cfm 0.8 1 sys#1 2 Central Unit/ None SEER: 16 29.4 kBtu/hr 882 cfm 0.8 2 sys#2 3 Central Unit/ None SEER: 16 29.4 kBtu/hr 882 cfm 0.8 3 sys#3 4 Central Unitt None SEER: 16 29.4 kBtu/hr 882 cfm 0.8 4 sys#4 HOT WATER SYSTEM it # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Exterior 0.98 80 gal 90 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS -- Supply --- --- Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 160 ft2 Attic 16 ft2 Default Leakage AHU 1 (Default) c(Default) c 1 1 2 Attic 6 120 ft2 Attic 12 ft2 Default Leakage AHU 2 (Default) c(Default) c 2 2 3 Attic 6 120 ft2 Attic 12 ft2 Default Leakage AHU 3 (Default) c(Default) c 3 3 4 Attic 6 120 ft2 Attic 12 ft2 Default Leakage AHU 3 (Default) c(Default) c 4 4 TEMPERATURES ProgrE able Thermostat: N i Ceiling Fans: Coolin Heating Jan Feb Jan Feb Mar [ Mar [ Apr [ Apr ( May l May X Jun [X Jul Jun l Jul Au ri Au Sep [ ] Oct rl Se [ ]Oct [ ]Nov [X] Nov Dec X Dec Ventin Jan Feb X Mar [X A r [ Ma [ Jun [ Jul Aug Se [X] Oct [X] Nov [ Dec Therm iat Schedule: HERS 2006 Reference Hours Schedules Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling D) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling EH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM I, 78 78 78 78 78 78 78 78 78 78 78 78 Heating D) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating EH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 AHU 1 Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 AHU 2 Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 AHU 3 Default 8 Ibs/s .ft. 0 ft2 O ft 0.3 AHU 4 EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 I ' 2017;- AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: AHMED RESIDENCE Builder Name: St , t: 7875 SADDLEBROOK DRIVE Permit Office: ST LUCIE COUNTY Cit ,State, Zip: PORT ST LUCIE, FL, Permit Number: Y U O ner: Jurisdiction: ST LUCIE COUNTY w v Deiiign Location: FL, ST_LUCIE_CO_INTL CO PONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA Genelal A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall 11 The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. require iiments Breaks or joints in the air barrier shall be sealed. Ceilin !/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim j fists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (inclu Ing maintain permanent contact with the underside of abov !,garage subfloor decking, or floor framing cavity insulation shall and c ntilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Craw i'�l Ispace walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shaft) �, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narro cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. GaraIIe separation Air sealing shall be provided between the garage and conditioned spaces. Rece sed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. JI Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pipinq and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Elect 'cal/phone box on The air barrier shall be installed behind electrical or communication exteri r walls boxes or air -sealed boxes shall be installed. HVA� register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. III Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprink`ers in a manner that is recommended by the manufacturer. Caulking or other I! adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In aaoitionI inspection of log walls shall be in accordance with the provisions of ICC-400. 7/23/21319 10:56 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 I _ f . 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location varies i! No. of units (if multiple -family) 3. 1 1. Number of bedrooms 4. 6 13. Cooling system: Capacity 129.2 j a) Split system SEER Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP i Conditioned floor area (sq. ft.) 6. 7522 d) Room unit/PTAC EER J. e) Other 16.0 Windows, type and area a) U-factor:(weighted average) 7a. 0.659 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.259 14. Heating system: Capacity 108.0 c) Area 7c. 888.3 a) Split system heat pump HSPF b) Single package heat pump HSPF Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other i. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 19.0 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas Fred, natural gas EF 0. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 5.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1061. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 1. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat No Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy aving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL isplay card will be completed based on installed code compliant features. ilder Signatu of New Home: 7875 SADDLEBROOK DRIVE City/FL Zip: PORT ST LUCIE, FL 9 10:56:08 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1