HomeMy WebLinkAboutENERGY EFFICIENCY CODE - 7-26-19FORN R405-2017
FLOZrida
'IDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Department of Business and Professional Regulation - Residential Performance Method
,lame:
i �,,FS
Project
AHMED RESIDENCE Builder Name:
"j
Street:
7875 SADDLEBROOK DRIVE Permit Office: ST LUCIE COUNTY
"te,
2 6
City, St
Zip: PORT ST LUCIE, FL, Permit Number:
JUL 2019
Owner:
Jurisdiction: ST LUCIE COUNTY
Design
location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Clim
tqoropUnty, Permitting
1. New c
instruction or existing New (From Plans)
9. Wall Types (6190.0 sqft.) Insulation Area
2. Single
family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior R=5.0 6190.00 ft2
IIr
b. N/A R= ft2
3. Numb
of units, if multiple family 1
c. N/A R= ft2
4. Numb
IIr of Bedrooms 6
d. N/A R= ft2
10. Ceiling Types (7522.0 sqft.) Insulation Area
5. Is this
a worst case? No
il
a. Roof Deck (Unvented) R=22.0 7522.00 ft2
6. Conditioned
floor area above grade (ft2) 7522
b. N/A R= ft2
Condil
toned floor area below grade (ft2) 0
c. N/A R= ft2
11. Ducts R ft2
7. Windows(888.3
sgft.) Description Area
2 additional duct system(s) 6 160
a. U-
actor: Sgl, U=0.65 723.00 ft2
b. Sup: Attic, Ret: Attic, AH: AHU 2 6 120
SH
C: SHGC=0.25
c. Sup: Attic, Ret: Attic, AH: AHU 3 (see details
b. U-F
actor: Sgl, U=0.70 165.33 ft2
12. Cooling systems kBtu/hr Efficiency
SH
C: SHGC=0.30
a. Central Unit 41.0 SEER:16.00
b. Central Unit 29.4 SEER:16.00
c. U_F
factor: N/A ft2
2 additional cooling systems (see details)
SHE
C:
13. Heating systems kBtu/hr Efficiency
d. U-Factor:
N/A ft2
a. Electric Strip Heat 27.0 COP:1.00
SH,
C:
b. Electric Strip Heat i27.0 COP:1.00
ApO g
2 heating ED details)
Area `,eighted
Average Overhang Depth: 2.000 ft.
additional systems (see
Area Weighted
Average SHGC: 0.259
14. Hot water systems V
8. Floor
I
(7522.0 sqft.) Insulation Area
a. Electric 99 Cap; 80 gallons
�u�'id® Ca Cap;
Hypes
a. Sla
On -Grade Edge Insulation R=0.0 4263.00 ft2
b. Conservation features
b. Rai:
ed Floor R=19.0 3259.00 ft2
None
c. NIA
R= ft2
15. Credits None
I
Glass/.I
Total Proposed Modified Loads: 225.85
loo�Area: 0.118 PASS
Total Baseline Loads: 226.29
I hereb
certify that the plans and specifications covered by
Review of the plans and Sx,4?A
this cal
ulation are in compliance with the Florida Energy
OZKE
specifications covered by this , s , .; O
Code.
calculation indicates compliance
with the Florida Energy Code.
PREP ..
DATE:
D-BY: -- Alsiblaki6m.0
Before construction is completed `
this building will be inspected for O
" - -��
�``--
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes. 1 ��
with the Florida Energy Code.-
OWNgR/AGENT:
BUILDING OFFICIAL:
DATE: I
DATE:
- Com ` liance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certi fed factory -sealed in accordance with R403.3.2.1.
- Com °liance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
9 10:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
i
FnRnn IzanS_91117 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
AHMED RESIDENCE
Bedrooms: 6
Address Type: Street Address
Buildin'
Type: User
Conditioned Area: 7522
Lot#
Owner
Name:
Total Stories: 1
Block/Subdivision:
# of U
its: 1
Worst Case: No
PlatBook:
Builde
!Name:
Rotate Angle: 0
Street: 7875 SADDLEBROOK
Permit
Office: ST LUCIE COUNTY
Cross Ventilation:
County: St. Lucie
Jurisdi
ition: ST LUCIE COUNTY
Whole House Fan:
City, State, Zip: PORT ST LUCIE,
Family,
l ype: Single-family
FL,
New/E
sting: New (From Plans)
Comm
J nt:
Ill
CLIMATE
v
Design Temp
Int Design Temp Heating Design Daily Temp
Design Location
i
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture Range
L, ST_LUCIE _CO_INTL FL_VERO_BEACH _MUNI 39 90
70
75 299 58 Medium
BLOCKS
Nurr6er
Name
Area Volume
1
I
Block1
2503 25030
2
Block2
1760 17600
3
I Block3
1701 17010
4
i Block4
1558 15580
!
i
SPACES
Nurnber
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
f
AHU 1
2503 25030 Yes 0
1
1 Yes Yes Yes
2
l AHU 2
I
1760 17600 No 0
2
1 Yes Yes Yes
3
AHU 3
1701 17010 Yes 0
1
1 Yes Yes Yes
4
i AHU 4
1558 15580 No 0
2
1 Yes Yes Yes
FLOORS
l # Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value Tile Wood Carpet
l 1 Slab -On -Grade Edge Insulation AHU 1 187 ft 0
ii
2503 ft2
e__ 1 0 0
j 2 Slab -On -Grade Edge Insulation AHU 2 111 ft 0
1760 ft2
---- 1 0 0
3 Raised Floor
AHU 3 ____ ---_
1701 ft2
19 1 0 0
i
4 Raised Floor
AHU 4 _-_- ____
1558 ft2
19 1 0 0
i
ROOF
/
Roof Gable Roof
Rad
Solar SA Emitt Emitt Deck Pitch
V
# Type
Materials Area Area Color
Barr
Absor. Tested Tested Insul. (deg)
t
1 Hip
Barrel tile 8148 ft2 0 ft2 Medium
N
0.2 No 0.9 No 22 22.6
ATTIC
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented 0 7522
ft2
N N
I
7/23/ I019 10:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
i
f
r
FORM
� 05-2017
INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented)
AHU 1
0
Blown
2503 ft2
0.11
Wood
2
Under Attic (Unvented)
AHU 2
0
Blown
1760 ft2
0.11
Wood
i
3
Under Attic (Unvented)
AHU 3
0
Blown
1701 ft2
0.11
Wood
4
i
Under Attic (Unvented)
AHU 4
0
Blown
1558 ft2
0.11
Wood
WALLS
Adjacent
Cavity
Width Height
Sheathing Framing Solar Below
Space
1
NE
Exterior
Concrete Block - Ext Insul
AHU 1
5
54
10
540.0 ft2
0
0 0.2
0
2
SE
Exterior
Concrete Block - Ext Insul
AHU 1
5
29
10
290.0 ft2
0
0 0.2
0
3
SW
Exterior
Concrete Block - Ext Insul
AHU 1
5
45
10
450.0 ft2
0
0 0.2
0
4
NW
Exterior
Concrete Black - Ext Insul
AHU 1
5
69
10
690.0 ft2
0
0 0.2
0
5
I
NE
Exterior
Concrete Block - Ext Insul
AHU 2
5
9
10
90.0 ft2
0
0 0.2
0
6
SE
Exterior
Concrete Block - Ext Insul
AHU 2
5
51
10
510.0 ft2
0
0 0.2
0
7
SW
Exterior
Concrete Block - Ext Insul
AHU 2
5
40
10
400.0 ft2
0
0 0.2
0
8
NW
Exterior
Concrete Block - Ext Insul
AHU 2
5
11
10
110.0 ft2
0
0 0.2
0
9
j NE
Exterior
Concrete Block - Ext Insul
AHU 3
5
38
10
380.0 ft2
0
0 0.2
0
10
SE
Exterior
Concrete Block - Ext Insul
AHU 3
5
19
10
190.0 ft2
0
0 0.2
0
_ 11
SW
Exterior
Concrete Block - Ext Insul
AHU 3
5
45
10
450.0 ft2
0
0 0.2
0
12
NW
Exterior
Concrete Block - Ext Insul
AHU 3
5
59
10
590.0 ft2
0
0 0.2
0
13
NE
Exterior
Concrete Block - Ext Insul
AHU 4
5
47
10
470.0 ft2
0
0 0.2
0
14
SE
Exterior
Concrete Block - Ext Insul
AHU 4
5
52
10
520.0 ft2
0
0 0.2
0
15
j SW
Exterior
Concrete Block - Ext Insul
AHU 4
5
40
10
400.0 ft2
0
0 0.2
0
16
NW
Exterior
Concrete Block - Ext Insul
AHU 4
5
11
10
110.0 ft2
0
0 0.2
0
i
DOORS
#
Omt
Door Type
Space
Storms U-Value
Width
Height
Area
Ft
In
Ft In
1
NW
Insulated AHU 1
None .17
2
8
8
21.3 ft2
2
NE
Insulated AHU 2
None .17
2
8
8
21.3 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
�/
#
Ornt ID
Frame Panes NFRC
U-Factor
SHGC
Imp Area
Depth
Separation
Int Shade
Screening
1
NE 1
Metal Low-E Single
Yes
0.65
0.25
Y 60.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2
NE 1
Metal Low-E Single
Yes
0.65
0.25
Y 16.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
3
NE 1
Metal Low-E Single
Yes
0.65
0.25
Y 30.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
4
NE 1
Metal Low-E Single
Yes
0.7
0.3
Y 48.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
5
SE 2
Metal Low-E Single
Yes
0.7
0.3
Y 24.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
6
SE 2
Metal Low-E Single
Yes
0.65
0.25
Y 20.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
I
7
SE 2
Metal Low-E Single
Yes
0.65
0.25
Y 15.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
8
SW 3
Metal Low-E Single
Yes
0.65
0.25
Y 30.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
9
SW 3
Metal Low-E Single
Yes
0.65
0.25
Y 12.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
10
SW 3
Metal Low-E Single
Yes
0.65
0.25
Y 6.0 ft2
2 It 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
I
I
i
I
i
7/23/2 i
i
I
19 10.55 AM
EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017)
Compliant Software
Page 3 of 5
Pr)PRA Ing-qn`17 INPI IT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
11
SW
3
Metal
Low-E Single
Yes
0.65
0.25
Y
16.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
12
NW
4
Metal
Low-E Single
Yes
0.65
0.25
Y
60.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
13
NW
4
Metal
Low-E Single
Yes
0.65
0.25
Y
24.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
i
14
SE
6
Metal
Low-E Single
Yes
0.65
0.25
Y
15.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
15
SE
6
Metal
Low-E Single
Yes
0.65
0.25
Y
6.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
16
SE
6
Metal
Low-E Single
Yes
0.65
0.25
Y
12.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
17
SW
7
Metal
Low-E Single
Yes
0.65
0.25
Y
30.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
18
SW
7
Metal
Low-E Single
Yes
0.65
0.25
Y
12.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
19
NW
8
Metal
Low-E Single
Yes
0.65
0.25
Y
15.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
20
SW
7
Metal
Low-E Single
Yes
0.7
0.3
Y
48.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
21
NW
8
Metal
Low-E Single
Yes
0.7
0.3
Y
21.3 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
i
22
NE
9
Metal
Low-E Single
Yes
0.65
0.25
Y
30.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
23
NE
9
Metal
Low-E Single
Yes
0.65
0.25
Y
20.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
24
SE
10
Metal
Low-E Single
Yes
0.7
0.3
Y
24.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
25
SE
10
Metal
Low-E Single
Yes
0.65
0.25
Y
15.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
j 26
SW
11
Metal
Low-E Single
Yes
0.65
0.25
Y
30.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
27
SW
11
Metal
Low-E Single
Yes
0.65
0.25
Y
16.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
i
28
NW
12
Metal
Low-E Single
Yes
0.65
0.25
Y
15.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
29
NW
12
Metal
Low-E Single
Yes
0.65
0.25
Y
8.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
30
NE
13
Metal
Low-E Single
Yes
0.65
0.25
Y
90.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
31
SE
14
Metal
Low-E Single
Yes
0.65
0.25
Y
15.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
32
SW
15
Metal
Low-E Single
Yes
0.65
0.25
Y
30.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
i 33
SW
15
Metal
Low-E Single
Yes
0.65
0.25
Y
60.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
i 34
I
NW
16
Metal
Low-E Single
Yes
0.65
0.25
Y
15.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
i
INFILTRATION
#
cope
Method
SLA
CFM 50
ELA
EgLA
ACH
ACH 50
1 Wt
II lehouse
Proposed ACH(50)
.000445
8775.7
481.77
906.04
.1685
7
HEATING SYSTEM
V !11#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
i 1
Electric Strip Heat/
None
COPA
27 kBtu/hr
1
sys#1
2
Electric Strip Heat/
None
COPA
27 kBtu/hr
2
sys#2
3
Electric Strip Heat/
None
COP:1
27 kBtu/hr
3
sys#3
4
Electric Strip Heat/
None
COP:1
27 kBtu/hr
4
sys#4
9 10:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
r=nRnn RI nF_gn17 IMP[ IT S[IMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow SHR
Block
Ducts
1 Central Unit/
None
SEER: 16
41 kBtu/hr
1230 cfm 0.8
1
sys#1
2 Central Unit/
None
SEER: 16
29.4 kBtu/hr
882 cfm 0.8
2
sys#2
3 Central Unit/
None
SEER: 16
29.4 kBtu/hr
882 cfm 0.8
3
sys#3
4 Central Unitt
None
SEER: 16
29.4 kBtu/hr
882 cfm 0.8
4
sys#4
HOT WATER SYSTEM
it # System Type
SubType
Location
EF
Cap
Use
SetPnt Conservation
1 Electric
None
Exterior
0.98
80 gal
90 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
-- Supply ---
--- Return --
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area
Leakage Type
Handler
TOT OUT QN
RLF
Heat Cool
1 Attic
6 160 ft2
Attic
16 ft2
Default Leakage
AHU 1
(Default) c(Default) c
1 1
2 Attic
6 120 ft2
Attic
12 ft2
Default Leakage
AHU 2
(Default) c(Default) c
2 2
3 Attic
6 120 ft2
Attic
12 ft2
Default Leakage
AHU 3
(Default) c(Default) c
3 3
4 Attic
6 120 ft2
Attic
12 ft2
Default Leakage
AHU 3
(Default) c(Default) c
4 4
TEMPERATURES
ProgrE
able Thermostat: N
i
Ceiling Fans:
Coolin
Heating
Jan Feb
Jan Feb
Mar
[ Mar
[ Apr
[ Apr
( May
l May
X Jun [X Jul
Jun l Jul
Au
ri Au
Sep [ ] Oct
rl Se [ ]Oct
[ ]Nov
[X] Nov
Dec
X Dec
Ventin
Jan Feb
X Mar
[X A r
[ Ma
[ Jun [ Jul
Aug
Se [X] Oct
[X] Nov
[ Dec
Therm
iat Schedule: HERS 2006
Reference
Hours
Schedules
Type
1
2 3
4
5 6
7
8 9 10
11
12
Cooling
D) AM
78
78 78
78
78 78
78
78 78 78
78
78
PM
78
78 78
78
78 78
78
78 78 78
78
78
Cooling
EH) AM
78
78 78
78
78 78
78
78 78 78
78
78
PM
I,
78
78 78
78
78 78
78
78 78 78
78
78
Heating
D) AM
68
68 68
68
68 68
68
68 68 68
68
68
PM
68
68 68
68
68 68
68
68 68 68
68
68
Heating
EH) AM
68
68 68
68
68 68
68
68 68 68
68
68
PM
68
68 68
68
68 68
68
68 68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
AHU 1
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
AHU 2
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
AHU 3
Default 8 Ibs/s .ft.
0 ft2
O ft
0.3
AHU 4
EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
I
' 2017;- AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project
Name: AHMED RESIDENCE Builder Name:
St
, t: 7875 SADDLEBROOK DRIVE Permit Office: ST LUCIE COUNTY
Cit
,State, Zip: PORT ST LUCIE, FL, Permit Number:
Y
U
O
ner: Jurisdiction: ST LUCIE COUNTY
w
v
Deiiign
Location: FL, ST_LUCIE_CO_INTL
CO
PONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
Genelal
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
11
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
require
iiments
Breaks or joints in the air barrier shall be sealed.
Ceilin
!/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows,
skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim j
fists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(inclu
Ing
maintain permanent contact with the underside of
abov
!,garage
subfloor decking, or floor framing cavity insulation shall
and c
ntilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Craw
i'�l
Ispace walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shaft) �, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narro cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
GaraIIe separation
Air sealing shall be provided between the garage and conditioned spaces.
Rece sed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
JI
Plumbing
and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind pipinq and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior
wall
tubs shall separate them from the showers and tubs.
insulated.
Elect
'cal/phone box on
The air barrier shall be installed behind electrical or communication
exteri
r walls
boxes or air -sealed boxes shall be installed.
HVA�
register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
III
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprink`ers
in a manner that is recommended by the manufacturer. Caulking or other
I!
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In aaoitionI inspection of log walls shall be in accordance with the provisions of ICC-400.
7/23/21319 10:56 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
I _
f .
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the Energy Performance Index, the more efficient the home.
New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location varies
i! No. of units (if multiple -family)
3.
1
1. Number of bedrooms
4.
6
13. Cooling system: Capacity
129.2
j
a) Split system SEER
Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
i Conditioned floor area (sq. ft.)
6.
7522
d) Room unit/PTAC EER
J.
e) Other
16.0
Windows, type and area
a) U-factor:(weighted average)
7a.
0.659
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.259
14. Heating system: Capacity
108.0
c) Area
7c.
888.3
a) Split system heat pump HSPF
b) Single package heat pump HSPF
Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
i. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
19.0
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.98
b) Gas Fred, natural gas EF
0. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
5.0
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1061.
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
1. Ceiling type and insulation level a) Ceiling fans
a) Under attic 11a. 0.0 b) Cross ventilation No
b) Single assembly 11b. c) Whole house fan No
c) Knee walls/skylight walls 11c. d) Multizone cooling credit
d) Radiant barrier installed 11d. No e) Multizone heating credit
0 Programmable thermostat No
Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
aving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
isplay card will be completed based on installed code compliant features.
ilder Signatu
of New Home: 7875 SADDLEBROOK DRIVE City/FL Zip: PORT ST LUCIE, FL
9 10:56:08 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1